Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Model

세 겹 구조 자가팽창형 스텐트그라프트의 혈관생체적합성: 개 모델 연구

  • Bae, Jae-Ik (Department of Radiology, Ajou University School of Medicine) ;
  • Won, Je-Hwan (Department of Radiology, Ajou University School of Medicine) ;
  • Jang, Eun-Ho (Department of Radiology, Ajou University School of Medicine) ;
  • Lee, Sung-Yeong (Department of Radiology, Ajou University School of Medicine) ;
  • Ko, Kwang-Tae (Department of Radiology, Ajou University School of Medicine) ;
  • Jin, Bo-Hwan (Medical Science Research Center, Ajou University School of Medicine) ;
  • Lee, Jun-Woo (Department of Radiology, Pusan National University Medical College) ;
  • Kim, Ji-Dae (Department of Radiology, Ajou University School of Medicine)
  • 배재익 (아주대학교 의과대학 영상의학과학교실) ;
  • 원제환 (아주대학교 의과대학 영상의학과학교실) ;
  • 장은호 (아주대학교 의과대학 영상의학과학교실) ;
  • 이성영 (아주대학교 의과대학 영상의학과학교실) ;
  • 고광태 (아주대학교 의과대학 영상의학과학교실) ;
  • 진보환 (아주대학교 의과대학 의과학연구소) ;
  • 이준우 (부산대학교 의과대학 영상의학과학교실) ;
  • 김지대 (아주대학교 의과대학 영상의학과학교실)
  • Received : 2011.07.16
  • Accepted : 2011.11.01
  • Published : 2012.02.01

Abstract

Purpose: To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Materials and Methods: Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Results: Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were $4.39mm^2$ (4 week) and $4.92mm^2$ (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. Conclusion: The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

목적: 새로 디자인된 형태로서 두 겹의 니티놀 스텐트 사이에 폴리테트로플루오르에틸렌막을 끼워서 고정한 세 겹 구조의 자가팽창형 스텐트그라프트의 혈관생체적합성을 개 모델에서 알아보고자 하였다. 대상과 방법: 여섯 마리의 개(평균체중 11 kg)에 각각 두 개의 스텐트그라프트(총 12개)를 대동맥 설치하고 2마리는 4주간 나머지 4마리는 12주간 추적관찰하였다. 스텐트그라프트 설치부의 내강의 변화를 보기 위하여 설치 전후 및 추적기간 후 혈관조영을 시행하였다. 신생내막의 증식정도와 염증정도는 광학현미경으로 관찰하고 측정하였다. 내막세포화의 정도와 성숙도는 전자현미경 검사를 시행하여 관찰하였다. 결과: 설치 후 혈류는 전 기간 동안 잘 유지되었고 혈전발생이나 스텐트그라프트 이동은 없었다. 12주 후 근위 비막(proximal bare)부분, 중간 막(middle graft)부분, 원위 비막(distal bare)부분 내강의 평균 퍼센트협착은 각각 13.5%, 3.9%, 9.6%였다. 4주군과 12주군의 중간 막부분의 평균 신생내막면적은 각각 평균 $4.39mm^2$$4.92mm^2$