DOI QR코드

DOI QR Code

How Can We Get the Best Results with Endoscopic Ultrasound-Guided Fine Needle Aspiration?

  • Ramesh, Jayapal (Division of Gastroenterology and Hepatology, Department of Medicine, University of Alabama at Birmingham School of Medicine) ;
  • Varadarajulu, Shyam (Division of Gastroenterology and Hepatology, Department of Medicine, University of Alabama at Birmingham School of Medicine)
  • 투고 : 2012.06.04
  • 심사 : 2012.06.14
  • 발행 : 2012.06.30

초록

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has evolved to become an indispensable tool for tissue acquisition. While the overall diagnostic accuracy of EUS-FNA is greater than 90% for lung cancer staging, it is lower for pancreatic mass lesions. Several factors such as location of the tumor, disease characteristics and procedural techniques determine the outcomes of EUS-FNA. In this review we evaluate the various technical factors that are keys to attaining optimal procedural outcomes.

키워드

피인용 문헌

  1. Endoscopic Ultrasound-Guided Fine Needle Aspiration: From the Past to the Future vol.2, pp.2, 2012, https://doi.org/10.4103/2303-9027.117691
  2. Diagnosis of Subepithelial Lesion: Still "Tissue Is the Issue" vol.46, pp.4, 2013, https://doi.org/10.5946/ce.2013.46.4.313
  3. Yields and Utility of Endoscopic Ultrasonography-Guided 19-Gauge Trucut Biopsy versus 22-Gauge Fine Needle Aspiration for Diagnosing Gastric Subepithelial Tumors vol.48, pp.2, 2012, https://doi.org/10.5946/ce.2015.48.2.152
  4. Meta-Analysis for Cyto-Pathological Outcomes in Endoscopic Ultrasonography-Guided Fine-Needle Aspiration With and Without the Stylet vol.61, pp.8, 2016, https://doi.org/10.1007/s10620-016-4130-5
  5. Diagnosis of pancreatic lesions collected by endoscopic ultrasound-guided fine-needle aspiration using next-generation sequencing vol.12, pp.5, 2016, https://doi.org/10.3892/ol.2016.5168
  6. Time-of-day effect and the yield of endoscopic ultrasound fine needle aspiration vol.5, pp.3, 2012, https://doi.org/10.4103/2303-9027.183980
  7. Repeat endoscopic ultrasound fine needle aspiration after a first negative procedure is useful in pancreatic lesions vol.5, pp.4, 2012, https://doi.org/10.4103/2303-9027.187889
  8. Risk factors associated with adverse events during endoscopic ultrasound-guided tissue sampling vol.12, pp.12, 2012, https://doi.org/10.1371/journal.pone.0189347
  9. A prospective randomized trial of EUS-guided tissue acquisition using a 25-gauge core biopsy needle with and without a stylet vol.32, pp.9, 2018, https://doi.org/10.1007/s00464-018-6166-4
  10. A quarter century of EUS-FNA: Progress, milestones, and future directions vol.7, pp.3, 2012, https://doi.org/10.4103/eus.eus_19_18
  11. Endoscopic Ultrasound-guided Fine-needle Aspiration Biopsy of a Renal Mass vol.21, pp.1, 2012, https://doi.org/10.7704/kjhugr.2020.0058