참고문헌
- Bilhan H, Erdogan O, Ergin S, Celik M, Ates G, Geckili O. Complication rates and patient satisfaction with removable dentures. J Adv Prosthodont 2012;4:109-15. https://doi.org/10.4047/jap.2012.4.2.109
- Takeshita S, Kanazawa M, Minakuchi S. Stress analysis of mandibular two-implant overdenture with different attachment systems. Dent Mater J 2011;30:928-34. https://doi.org/10.4012/dmj.2011-134
- van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6. https://doi.org/10.1046/j.0905-7161.2003.00961.x
- Fenlon MR, Sherriff M, Walter JD. Association between the accuracy of intermaxillary relations and complete denture usage. J Prosthet Dent 1999;81:520-5. https://doi.org/10.1016/S0022-3913(99)70205-2
- Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002;19:3-4. https://doi.org/10.1111/j.1741-2358.2002.00003.x
- Vercruyssen M, Marcelis K, Coucke W, Naert I, Quirynen M. Long-term, retrospective evaluation (implant and patient-centred outcome) of the two-implants-supported overdenture in the mandible. Part 1: survival rate. Clin Oral Implants Res 2010; 21:357-65. https://doi.org/10.1111/j.1600-0501.2009.01849.x
- Thomason JM, Kelly SA, Bendkowski A, Ellis JS. Two implant retained overdentures-a review of the literature supporting the McGill and York consensus statements. J Dent 2012;40:22-34. https://doi.org/10.1016/j.jdent.2011.08.017
- Hong JW, Ahn SG, Leem DH, Seo JM. Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report. J Adv Prosthodont 2012;4:52-6. https://doi.org/10.4047/jap.2012.4.1.52
- Esposito M, Grusovin MG, Willings M, Coulthard P, Worthington HV. Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev 2007 Apr 18;(2):CD003878.
- Esposito M, Grusovin MG, Chew YS, Coulthard P, Worthington HV. Interventions for replacing missing teeth: 1- versus 2- stage implant placement. Cochrane Database Syst Rev 2009 Jul 8;(3):CD006698.
- Stoumpis C, Kohal RJ. To splint or not to splint oral implants in the implant-supported overdenture therapy? A systematic literature review. J Oral Rehabil 2011;38:857-69. https://doi.org/10.1111/j.1365-2842.2011.02220.x
- Spazzin AO, Dos Santos MB, Sobrinho LC, Consani RL, Mesquita MF. Effects of horizontal misfit and bar framework material on the stress distribution of an overdenture-retaining bar system: a 3D finite element analysis. J Prosthodont 2011;20:517-22. https://doi.org/10.1111/j.1532-849X.2011.00759.x
- Deslis A, Hasan I, Bourauel C, Bayer S, Stark H, Keilig L. Numerical investigations of the loading behaviour of a prefabricated non-rigid bar system. Ann Anat 2012 May 11.
피인용 문헌
- Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study vol.26, pp.2, 2015, https://doi.org/10.1111/clr.12304
- A Retrospective 2-Year Clinical Study of Immediate Prosthetic Rehabilitation of Edentulous Jaws with Four Implants and Prefabricated Bars vol.26, pp.5, 2017, https://doi.org/10.1111/jopr.12406
- Wear, microleakage and plastic deformation of an implant-supported chair-side bar system vol.7, pp.4, 2015, https://doi.org/10.4047/jap.2015.7.4.323
- Implant-retained overdentures with pre-fabricated bar attachment system in edentulous patients vol.54, pp.1, 2016, https://doi.org/10.4047/jkap.2016.54.1.41
- Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study vol.2018, pp.2314-6141, 2018, https://doi.org/10.1155/2018/7352125
- Implant Inclination and Horizontal Misfit in Metallic Bar Framework of Overdentures: Analysis By 3D-FEA Method vol.29, pp.2, 2018, https://doi.org/10.1590/0103-6440201801672
- Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns – a finite element analysis vol.93, pp.2, 2012, https://doi.org/10.15386/mpr-1312