Magnet retained intraoral-extra oral combination prosthesis: a case report

  • 투고 : 2011.10.25
  • 심사 : 2012.05.07
  • 발행 : 2012.11.30

초록

Facial prosthesis is generally considered over surgical reconstruction to restore function and appearance in patients with facial defects that resulted from cancer resection. Retention of the prosthesis is challenging due to its size and weight. Retention can be achieved by using medical grade adhesives, resilient attachments, clips and osseointegrated implants. It can also be connected to obturator by magnets. This clinical report highlights the rehabilitation of a lateral midfacial defect with a two piece prosthesis that included an extra oral facial prosthesis and an intraoral obturator with the use of magnets.

키워드

참고문헌

  1. Marunick MT, Harrison R, Beumer J 3rd. Prosthodontic rehabilitation of midfacial defects. J Prosthet Dent 1985;54:553-60. https://doi.org/10.1016/0022-3913(85)90433-0
  2. Guttal SS, Patil NP, Shetye AD. Prosthetic rehabilitation of a midfacial defect resulting from lethal midline granuloma-a clinical report. J Oral Rehabil 2006;33:863-7. https://doi.org/10.1111/j.1365-2842.2006.01616.x
  3. Cowan PW. An obturator prosthesis. Quintessence Int 1985;16:403-5.
  4. Sykes LM, Essop RM. Combination intraoral and extraoral prosthesis used for rehabilitation of a patient treated for cancrum oris: a clinical report. J Prosthet Dent 2000;83:613-6.
  5. Thomas K. Prosthetic rehabilitation. London: Quintessence Publishing; 1994. p. 93-103.
  6. Menneking H, Klein M, Hell B, Bier J. Prosthetic restoration of nasal defects: Indications for two different osseointegrated implant systems. J Facial Somato Prosthet 1998;4:29-33.
  7. Worthington P, Branemark PI. Advanced osseointegration surgery applications in the maxillofacial region. Carol Stream, Il, Quintessence; 1992. p. 307-26.
  8. Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Prosthet Dent 1991;66:536-40. https://doi.org/10.1016/0022-3913(91)90519-3
  9. Arcuri MR, LaVelle WE, Fyler E, Jons R. Prosthetic complications of extraoral implants. J Prosthet Dent 1993;69:289-92. https://doi.org/10.1016/0022-3913(93)90108-Z
  10. Roumanas E, Nishumura R, Beumer J, Moy P, Weinlander M, Lorant J. Osseointegrated implants: Six-year follow-up report on the success rates of craniofacial implants at UCLA. Int J Oral Maxillofac Implants 1994;9:579-85.
  11. Patil PG. Modified technique to fabricate a hollow light-weight facial prosthesis for lateral midfacial defect: a clinical report. J Adv Prosthodont 2010;2:65-70. https://doi.org/10.4047/jap.2010.2.3.65
  12. Matalon V, LaFuente H. A simplified method for making a hollow obturator. J Prosthet Dent 1976;36:580-2. https://doi.org/10.1016/0022-3913(76)90308-5
  13. Schneider A. Method of fabricating a hollow bulb obturator. J Prosthet Dent 1978;40:351. https://doi.org/10.1016/0022-3913(78)90046-X

피인용 문헌

  1. Prosthetic Rehabilitation of a Lateral Midfacial Defect Combined with Hemimandibulectomy using Multiple/Sectional Prosthesis vol.4, pp.4, 2012, https://doi.org/10.5005/jp-journals-10019-1120
  2. Prosthetic Rehabilitation of a Lateral Midfacial Defect Combined with Hemimandibulectomy using Multiple/Sectional Prosthesis vol.4, pp.4, 2012, https://doi.org/10.5005/jp-journals-10019-1120
  3. THE CHANGING CONCEPTS IN THE RETENTION OF MAXILLOFACIAL PROSTHESIS FROM PAST TO PRESENT- A REVIEW vol.6, pp.84, 2012, https://doi.org/10.14260/jemds/2017/1277