Abstract

This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Keywords

References

  1. M. Klotz, H. Rohling, "A 24 GHz short range radar network for automotive applications," in Proc. IEEE Radar Conf., pp. 115-199, 2001.
  2. A. Droitcour, O. B. Lubecke, V. M. Lubecke, J. Lin, and G. Kovacs, "Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring," IEEE Trans. Microwave Theory Tech., vol. 52, pp. 838- 848, Mar. 2004. https://doi.org/10.1109/TMTT.2004.823552
  3. E. F. Greneker, "Radar sensing of heartbeat and respiration at a distance with applications of the technology," in Proc. IEEE Radar Conf., pp. 150-154, 1997.
  4. C. Li, Y. Xiao, and J. Lin, "A 5 GHz double-sideband radar sensor chip in 0.18 mm CMOS for noncontact vital sign detection," IEEE Microwave and Wireless Components Lett., vol. 18, pp. 494-496, Jul, 2008. https://doi.org/10.1109/LMWC.2008.925112
  5. C. Li, X. Yu, C. Lee, L. Ran, and J. Lin, "Highsensitivity software configurable 5.8 GHz radar sensor receiver chip in 0.13 ${\mu}m$ CMOS for noncontact vital sign detection," IEEE Trans. Microwave Theory Tech., vol. 58, pp. 1410-1419, May 2010. https://doi.org/10.1109/TMTT.2010.2042856
  6. T. Y. Kao, A. Chen, Y. Yan, T. M. Shen, and J. Lin, "A flip-chip-packaged and fully integrated 60 GHz CMOS micro-radar sensor for heartbeat and mechanical vibration detections," in Proc. IEEE RFIC Symp., pp. 443-446, Jun, 2012.
  7. P. Abele, A. Trasser, E. Sonmez, K. B. Schad, A. Munding, and H. Schumacher, "A compact low-cost Doppler sensor MMIC in SiGe technology for the ISM band at 24 GHz," in Proc. 34th European Microwave Conf., pp. 1037-1040, 2004.
  8. P. D. L. Beasley, A. G. Stove, and B. J. Reits, "Solving the problems of a single antenna frequency modulated CW radar," in Proc. IEEE Radar Conf., pp. 391-395, 1990.
  9. A. Tessmann, S. Kudszus, T. Feltgen, M. Riessle, C. Sklarczyk, and H. Haydl, "Compact single-chip Wband FMCW radar modules for commercial highresolution sensor applications," IEEE Trans. Microwave Theory Tech., vol. 50, pp. 2995-3001, Dec. 2002. https://doi.org/10.1109/TMTT.2002.805162
  10. J. G. Kim, S. S. Ko, S. H. Jeon, J. W. Park, and S. C. Hong, "Balanced topology to cancel Tx leakage in CW radar," IEEE Microwave and Wireless Components Lett., vol. 14, pp. 443-445, Sep. 2004. https://doi.org/10.1109/LMWC.2004.832080

Cited by

  1. Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement vol.8, pp.4, 2014, https://doi.org/10.1109/TBCAS.2013.2280913
  2. Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator vol.27, pp.3, 2016, https://doi.org/10.5515/KJKIEES.2016.27.3.299
  3. Design of Dual-Mode Local Oscillators Using CMOS Technology for Motion Detection Sensors vol.18, pp.4, 2018, https://doi.org/10.3390/s18041057