Abstract
The limitation of the yield strength in reinforced concrete columns is given for the effective use of high-strength steel bar, because very high-strength steel bar does not yield while concrete fails in compression. In order to overcome this limitation, it is required to increase peak strain of the concrete. The objective of this study is to examine the confinement effect of plate type lateral reinforcement in reinforced concrete columns. From this experimental study, the reinforced concrete columns confined by plate type carbon fiber sheets showed higher compressive strength and peak concrete strain comparing to the unconfined columns. The confinement effect is higher when cross-sectional type is a circular one than a square one. Moreover, the confinement effect was also higher for circular type confinement. Based on this study, high-strength steel bars with strength exceeding 800 MPa can be effectively used for reinforced concrete columns confined by plate type lateral reinforcements.
콘크리트구조설계기준에서는 철근콘크리트 기둥에서 주철근의 설계기준항복강도를 550 MPa 이하로 규정하고 있다. 이는 철근콘크리트 기둥에 주철근으로 고강도 철근(high-strength concrete)을 사용할 때 콘크리트가 압축강도에 도달하여도 주철근이 항복변형률에 도달하지 않아 고강도 철근을 효율적으로 사용할 수 없기 때문이다. 철근의 설계기준항복강도 제한의 문제점을 해결하기 위한 방법으로는 횡구속력(confinement effect)을 가해주는 방법과 콘크리트의 파괴변형률(peak strain)을 증진시켜주는 방법이 있다. 횡구속을 효과적으로 가하는 방법으로서 원형 단면의 철근보다는 판재를 사용하는 것이 바람직하다. 이 연구에서는 가공이 용이한 판재로서 탄소섬유판을 철근콘크리트 기둥에서 횡구속효과를 위한 구조재료로 사용하였을 경우 보강되지 않은 경우보다 증진된 압축강도 및 축압축 파괴변형률을 보였으며, 콘크리트 단면 형상이 원형에 가까울수록, 횡구속 형태가 원형에 가까울수록 횡구속 효과는 더욱 커졌다. 최종적으로 실험 결과를 토대로 철근콘크리트 기둥에서 탄소섬유판에 의한 횡구속 효과와 함께 고강도 철근의 적용 가능성을 확인하였다.