DOI QR코드

DOI QR Code

Correction of Rotated Objects in Medical Images Using the Mojette Transform

모젯 변환을 이용한 의료 영상의 회전 물체 보정

  • Received : 2012.10.09
  • Accepted : 2012.10.24
  • Published : 2012.11.30

Abstract

In this paper, an efficient scheme for correcting rotated objects in medical images using the Mojette transform is presented. The Mojette transform is a kind of discrete Radon transform, where the transform domain is represented by a set of projections. The Mojette transform currently studied in the image compression area is modified for detecting the rotation angle of objects in medical images. First, in order to find accurate rotation angle, the projection value in the Mojette transform is determined by using pixels on the projection line and in addition the linear interpolation of pixels adjacent to the line. Second, at each projection angle, only one projection is implemented for reducing the amount of the calculation in the process of the Mojette transform. Finally, the projection in the Mojette transform is carried out at the predetermined ROI(Region Of Interest) at which the objects are not cropped or added by rotating the image. The simulation results show that the proposed method has good performance for correcting the rotation angle in medical images.

본 논문에서는 변형된 모젯 변환을 이용하여 의료영상에서 회전된 물체의 회전각을 추출하고 보정하는 새로운 방법을 제안한다. 모젯 변환은 이산 형태의 라돈 변환으로서 변환 영역은 입력 영상에 대한 투영값으로 구성된다. 최근 영상 정보의 압축을 위해 주로 연구되던 모젯 변환을 회전 물체의 보정에 적용하기 위해 본 논문에서는 다음과 같이 모젯 변환을 변형하여 사용한다. 먼저 회전 영상에서 정확한 회전각을 추출하기 위해, 투영선 상의 화소 뿐만 아니라 투영선에 인접한 화소들도 투영값 계산에 반영한다. 그리고 모젯 변환에서의 계산량 감소를 위해 각 투영 방향에 대해 영상의 중심 화소를 통과하는 하나씩의 투영만을 실행한다. 또한 대상 영상이 회전 영상임을 고려하여 영상의 회전 시 삭제되거나 추가되지 않는 관심 영역을 설정하여 이 영역에 대해서만 투영값을 계산한다. 모의실험을 통해 제안된 방법이 다양한 의료 영상의 회전각 추출 및 보정에 매우 효율적임을 알 수 있었다.

Keywords

References

  1. 조보호, 정성환, "라돈 변환을 이용한 회전된 물체의 효율적인 보정," 정보과학회논문지, 제14 권 제3호, pp. 291-295, 2008.
  2. A. Kingston and F. Autrusseau, "Lossless Image Compression via Predictive Coding of Discrete Radon Transform," Signal Processing Image Communication, Vol. 23, No. 4, pp. 313-324, 2008. https://doi.org/10.1016/j.image.2008.03.001
  3. A. Kingston, I. Svalbe, and J.P. Guedon, "The Discrete Radon Transform: A More Efficient Approach to Image Reconstruction," Proc. of SPIE, Vol. 7078, pp. G1-G10, 2008.
  4. F. Autrusseau, B. Parrein, and M. Servieres, "Lossless Compression Based on a Discrete and Exact Radon Transform: A Preliminary Study," ICASSP , Vol. II, pp. 425-428, 2006.
  5. N. Normand, A. Kingston, and P. Evenou, A Geometry Driven Reconstruction Algorithm for the Mojette Transform, http://hal.archives- ouvertes.fr/docs/00/26/76/28/PDF/ normand2006dgci.pdf, 2008.
  6. M. Katz, Questions of Uniqueness and Resolution in Reconstruction from Projections, Lect. Notes in Biomath., Springer Verlag, Berlin, Germany, 1977.
  7. J. P. Guedon, N. Normand, The Mojette Transform: The First Ten Years, http:// hal.archives-ouvertes.fr/docs/00/26/76/21/ PDF/guedon2005dgci.pdf, 2008.
  8. Set of medical and natural continuous tone grayscale images for evaluating image compression algorithms, http://sun.aei.polsl.pl/ -rstaros/mednat/index.html.
  9. 의료영상정보연구회, 의료영상정보학, 청구문화사, 2010.
  10. J. S. Lim, Two-Dimensional Signal And Image Processing, Prentice-Hall, Inc., New Jersey, USA, 1990.

Cited by

  1. Correction of Rotated Region in Medical Images Using SIFT Features vol.18, pp.1, 2015, https://doi.org/10.9717/kmms.2015.18.1.017
  2. 변형된 모젯 변환을 이용한 동영상에서의 회전 프레임 보정 vol.16, pp.1, 2012, https://doi.org/10.9717/kmms.2013.16.1.042