Abstract
The bonded tendon was adopted to the reactor containment building of some operating nuclear power plants in Korea and the assessment of the prestress force on the bonded tendon is very important for the evaluation of the structural integrity. The prestress force of the bonded tendon at real reactor containment building, was evaluated using the SI technique and impact signal analysis technique which were developed to improve the existing indirect assessmment technique. For these techniques, the strain of the reactor containment building and the stress wave velocity of the bonded tendon were measured. Both SI technique and impact signal analysis technique give the highly reliable results comparison with the existing theoretical approach. Therefore, it is confirmed that the developed techniques are very useful for the evaluation of the prestress force on the bonded tendon.
국내 일부 가동 중 원전의 원자로건물에 부착식 텐던이 시공되어 있고, 이들에 대한 긴장력 평가는 원자로건물의 구조 건전성 평가 시 매우 중요하다. 따라서, 본 논문에서는 기존의 간접적인 부착식 텐던의 긴장력 평가방법을 개선하기 위하여 개발된 SI 기술과 충격신호 분석기술을 이용하여 실제 원자로건물에 매입된 부착식 텐던을 대상으로 긴장력을 평가하였다. 이를 위해 원자로건물에서 발생하는 변형률과 부착식 텐던에서 발생하는 응력파속도를 계측하였다. 이들을 통해 부착식 텐던의 긴장력을 평가한 결과, SI 기술과 충격신호 분석기술 모두 높은 신뢰성 있는 결과를 제시하였고, 기존의 이론적인 접근 방법에 의한 결과와도 매우 유사한 경향을 제시함으로써 본 연구진에서 개발한 부착식 텐던의 긴장력 평가방법이 매우 유용함을 확인할 수 있었다.