Abstract
When a heavy rain brings flooding, a high turbid water is flowing into a reservoir. In this study, the effectiveness of the intake structures for the selective withdrawal from the various levels of a stratified reservoir was evaluated by the field experiments and the numerical modeling of the three-dimensional approaching flows. The temperature, the turbidity, and the velocity fields for the selective withdrawal were measured using both YSI6600EDS and YSI6600ADV, respectively. A threedimensional model, FLOW-3D, was used to predict the performance of the intake tower in Imha reservoir. The comparisons of the vertical velocity field showed a good agreement with the field measurements. The efficiency of the turbid-water elimination of the selective withdrawal method from low levels was higher up to 46% than that of the surface withdrawal. From the analysis of the numerical simulation, the efficiency of turbidity elimination increased by 10% for the selective withdrawal from middle levels, and by 30% from low levels. These results showed that the selective withdrawals from middle and low levels are more effective than the surface-water intake. The similar results were obtained by the one-dimensional model, SELECT, which is much more computationally time-efficient.
유역에서 집중호우가 발생하였을 경우 저수지 내로 고탁수층이 유입된다. 본 연구에서는 성층저수지로 유입된 고탁수층에 대한 선택취수 탁수배제 능력을 검토하기 위하여 3차원적인 접근흐름에 대한 현장실험 및 수치해석 연구를 수행하였다. 다항목수질모니터링시스템(YSI6600EDS)과 초음파유속계(YSI6600ADV)을 이용하여 선택취수시의 온도, 탁도 및 유속분포를 측정하였다. 3차원 모형인 FLOW-3D를 이용하여 저수지 내 취수탑 주변에서 유동형태를 예측하였으며, 현장실험에서의 유속 측정값과 비교분석한 결과 연직유속분포를 잘 모의함을 확인할 수 있었다. 또한 관측 자료들을 분석한 결과에 의하면 표면 취수에 비해 저층 선택취수를 수행하는 것이 고탁수층에 대한 저수지내 탁도 배제능력이 46% 증가하는 것으로 나타났다. 3차원 수치모의 해석결과, 표면취수에 비하여 중층취수를 하는 경우에는 저수지내 탁도 배제능력이 10% 증가하였고, 저층취수를 하는 경우에는 30% 증가하였다. 따라서 저수지 내 고탁수를 배제하기 위해서는 중층 또는 저층의 선택취수를 수행하는 것이 탁수배제 능력 면에서 우수한 것으로 분석되었다. 또한 수치효율이 매우 높은 1차원 SELECT 모형에서도 유사한 결과를 보여 주었다.