References
- Neumann, D.A. Kinesiology of the Musculoskeletal System: Foundations for Rehabilitation, Mosby Elsevier, pp. 28-45.
- Piazza, S.J., Okita, N. and Cavanagh, P.R. 2001, Accuracy of the Functional Method of Hipjoint Center Location, Journal of Biomechanics, 34, pp. 967-973. https://doi.org/10.1016/S0021-9290(01)00052-5
- Bartz, R.L., Noble, P.C., Kadakia, N.R. and Tullos, H.S. 2012, The Effect of Femoral Component in Artificial Hip Joint, The Journal of Bone and Joint Surgery, pp. 1300-1307.
- Lenaerts, G., De Groote, F., Demeulenaere, B., Mulier, M., Van der Perre, G., Spaepen, A. and Jonkers, I., 2008, Subject-specific Hip Geometry Affects Predicted Hip Joint Contact Forces During Gait, Journal of Biomechanics, 41, pp. 1243-1252. https://doi.org/10.1016/j.jbiomech.2008.01.014
- Arnold, A.S., Blemker, S.S. and Delp, S.L. 2001, Evaluation of a Deformable Musculoskeletal Model for Estimating Muscle-Tendon Lengths During Crouch Gait. Annals of Biomedical Engineering, 29, pp. 263-274. https://doi.org/10.1114/1.1355277
- Carter, D.R., van der Meulen, M.C.H. and Beaupre, G.S., 2001, Mechanical Factors in Bone Growth and Development. BONE, pp. 1-6.
- Arnold, A.S. and Delp, S.L., 2001, Rotational Moment Arms of the Medial Hamstrings and Adductors Vary with Femoral Geometry and Limb Position: Implications for the Treatment of Internally Rotated Gait, Journal of Biomechanics, pp. 1-11.
- Pennestri, E., Stefanelli, R., Valentini, P.P. and Vita, L., 2007, Virtual Musculo-skeletal Model for the Biomechanical Analysis of the Upper Limb, Journal of Biomechanics, 40(6), pp. 1350-1361. https://doi.org/10.1016/j.jbiomech.2006.05.013
- Delp, S.L. and Loan, J.P., 1995, A Graphicbased Software System to Develop and Analyze Models of Musculoskeletal Structures, Computers in Biology and Medicine, pp. 21-34.
- Delp, S.L., Anderson, F.C., Arnold, A.S., Loan, P., Habib, A., John, C.T., Guendelman, E., et al., 2007. OpenSim: Open-Source Software to Create andAnalyze Dynamic Simulations of Movement, IEEE Transactions on Biomedical Engineering, 54, pp. 1940-1950. https://doi.org/10.1109/TBME.2007.901024
- Blemker, S.S., Asakawa, D.S., Gold, G.E. and Delp, S.L., 2007, Image-Based Musculoskeletal Modeling- Applications, Advances, and Future Opportunities. Journal of Magnetic Resonance Imaging, 25, pp. 441-451. doi:10.1002/jmri.20805
- Scheys, L., Desloovere, K., Suetens, P. and Jonkers, I., 2011, Level of Subject-specific Detail in Musculoskeletal Models Affects Hip Moment Arm Length Calculation During Gait in Pediatric Subjects with Increased Femoral Anteversion. Journal of Biomechanics, 44(7), pp. 1346-1353. https://doi.org/10.1016/j.jbiomech.2011.01.001
- Lenaerts, G., De Groote, F., Demeulenaere, B., Mulier, M., Van der Perre, G., Spaepen, A. and Jonkers, I., 2008, Subject-specific Hip Geometry Affects Predicted Hip Joint Contact Forces During Gait, Journal of Biomechanics, 41, pp. 1243-1252. https://doi.org/10.1016/j.jbiomech.2008.01.014
- Rajamani, K.T., Hug, J., Nolte, L.-P. and Styner, M., 2004, Bone Morphing with Statistical Shape Models for Enhanced Visualization, In: Proceedings of SPIE Medical Imaging (Vol. 5367, pp. 122-130). Presented at the In: Proceedings of SPIE Medical Imaging, SPIE.
- Rajamani, K.T., Styner, M.A., Talib, H., Zheng, G., Nolte, L.P. and Ballester, M.A.G., 2007, Statistical Deformable Bone Models for Robust 3D Surface Extrapolation from Sparse Data, Medical Image Analysis, 11(2), pp. 99-109. https://doi.org/10.1016/j.media.2006.05.001
- Park, B.K., Chae, J.W. and Kim, J.J., 2011, Parametric Morphing of Subject-specific NURBS Models for Human Proximal Femurs Subject to Femoral Functions, Transactions of the Society of CAD/CAM Engineers, 16(6), pp. 458-466.
- Delp, S.L., Loan, J.P., Hoy, M.G., Zajac, F.E., Topp, E.L. and Rosen, J.M., 1990, An Interactive Graphics-based Model of the Lower Extremity to Study Orthopaedic Surgical Procedures. IEEE Transactions on Biomedical Engineering 37, pp. 757-767. https://doi.org/10.1109/10.102791
- Sciavicco, L., Siciliano, B., 1996, Modelling and Control of Robot Manipulators. Second Edition, London: Springer-Verlag. pp. 166-191.
- Delp, S.L., 1990, Surgery Simulation: A Computer Graphics System to Analyze and Design Musculoskeletal Reconstructions of the Lower Limb, Ph.D. dissertation, Stanford University.
- Zajac, F.E., 1989, Muscle and Tendon: Properties, Models, Scaling and Application to Biomechanics and Motor Control, CRC Critical Reviews in Biomedical Engineering 17, pp. 359-411.
- Thelen, D.G. and Anderson, F.C., 2006, Using Computed Muscle Control to Generate Forward Dynamic Simulations of Human Walking from Experimental Data, Journal of Biomechanics, 39, pp. 1107-1115. https://doi.org/10.1016/j.jbiomech.2005.02.010
- Jun, Y.T. and Choi, K., 2010, Design of Patientspecic Hip Implants Based on the 3D Geometry of the Human Femur, Advances in Engineering Software, 41, pp. 537-547. https://doi.org/10.1016/j.advengsoft.2009.10.016
- Andersen, M.S., Damsgaard, M. and Rasmussen, J., 2009, Kinematic Analysis of Over-determinate Biomechanical Systems, Computer Methods in Biomechanics and Biomedical Engineering, 12(4), pp. 371-384. https://doi.org/10.1080/10255840802459412