DOI QR코드

DOI QR Code

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes

코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정

  • Kim, Hak-Jin (Dept. of Biosystems Engineering and Biomaterials Science, Seoul National University) ;
  • Son, Dong-Wook (Dept. of Bio-Industrial Machinery Engineering, Pusan National University) ;
  • Kwon, Soon-Goo (Dept. of Bio-Industrial Machinery Engineering, Pusan National University) ;
  • Roh, Mi-Young (National Institute of Horticultural and Herbal Science) ;
  • Kang, Chang-Ik (Science and Technology Analysis Center) ;
  • Jung, Ho-Seop (Dept. of Mechanical and Aerospace Engineering, Seoul National University)
  • 김학진 (서울대학교 바이오시스템.소재학부) ;
  • 손동욱 (부산대학교 바이오산업기계공학과) ;
  • 권순구 (부산대학교 바이오산업기계공학과) ;
  • 노미영 (국립원예특작과학원 시설원예시험장) ;
  • 강창익 ((주)과학기술분석센타) ;
  • 정호섭 (서울대학교 기계.항공시스템공학부)
  • Received : 2011.09.16
  • Accepted : 2011.10.06
  • Published : 2011.10.25

Abstract

The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

Keywords

References

  1. Dybko, A. 2001. Errors in chemical sensor measurements. Sensors 1:29-37. https://doi.org/10.3390/s10100029
  2. Engblom, S. O. 1999. Determination of inorganic phosphate in a soil extract using a cobalt electrode. Plant Soil 206(2):173-179.
  3. Gallardo, J., S. Alegret, R. Munoz, M. De-Roman, L. Leija, P. R. Hernandez, and M. d. Valle. 2003. An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water. Analytical and Bioanalytical Chemistry 377: 248-256. https://doi.org/10.1007/s00216-003-2042-7
  4. Gallardo, J., S. Alegret, and M. D. Valle. 2004. A flowinjection electronic tongue based on potentiometric sensors for the determination of nitrate in the presence of chloride. Sensors and Actuators B 101:72-80. https://doi.org/10.1016/j.snb.2004.02.027
  5. Gutierrez, M., S. Alegret, R. Caceres, J. Casadesus, O. Marfa, and M. del Valle. 2007. Application of a potentiometric electronic tongue to fertigation strategy in greenhouse cultivation. Computers and Electronics in Agriculture 57(1):12-22. https://doi.org/10.1016/j.compag.2007.01.012
  6. Kim, G. 2003. Application of a strip ion-selective electrode sensor for hydroponic nutrient solution analysis - $NO_3$ analysis-. Journal of the Korean Society for Agricultural Machinery 28(4): 335-342. (In Korean) https://doi.org/10.5307/JBE.2003.28.4.335
  7. Kim, H. J., J. W. Hummel, and S. J. Birrell. 2006a. Evaluation of nitrate and potassium ion-selective membranes for soil macronutrient sensing. Transactions of the ASABE 49(3):597-606. https://doi.org/10.13031/2013.20476
  8. Kim, H. J., J. W. Hummel, and K. A. Sudduth. 2006b. Sensing nitrate and potassium ions in soil extracts using ion-selective electrodes. Journal of Biosystems Engineering. 31(6):463-473. https://doi.org/10.5307/JBE.2006.31.6.463
  9. Kim, H. J., J. W. Hummel, K. A. Sudduth, and S. J. Birrell. 2007a. Evaluation of phosphate ion-selective membranes and cobalt-based electrodes for soil nutrient sensing. Transactions of the ASABE 50(2):215-225.
  10. Kim, H. J., J. W. Hummel, K. A. Sudduth, and P. P. Motavalli. 2007b. Simultaneous analysis of soil macronutrients using ion-selective electrodes. Soil Science Society America Journal 71(6):1867-1877. https://doi.org/10.2136/sssaj2007.0002
  11. Kim, W. K., T. S. Park, Y. J. Kim, M. Y. Roh, S. I. Cho, and H. J. Kim. 2010. Sensing $NO_3$-N and K ions hydroponic solution using ion-selective membranes. Journal of Biosystems Engineering 35(5):343-349. (In Korean) https://doi.org/10.5307/JBE.2010.35.5.343
  12. Sonneveld, C. 2002. Composition of nutrient solutions. In: Hydroponic production of vegetables and ornamentals, ed(s). D. Savvas and H.C. Passam. pp. 179-210. Athens, Greece: Embryo publications.
  13. Xiao, D., H. Y. Yuan, J. Li, and R. Q. Yu. 1995. Surfacemodified cobalt-based sensor as a phosphate-sensitive electrode. Analytical Chemistry 67:288-291. https://doi.org/10.1021/ac00098a009

Cited by

  1. On-site ion monitoring system for precision hydroponic nutrient management vol.146, 2018, https://doi.org/10.1016/j.compag.2018.01.019
  2. An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes vol.41, pp.2, 2016, https://doi.org/10.5307/JBE.2016.41.2.075
  3. Automated sensing of hydroponic macronutrients using a computer-controlled system with an array of ion-selective electrodes vol.93, 2013, https://doi.org/10.1016/j.compag.2013.01.011