References
- Rose, E.A., Gelijns, A.C., Moskowitz, A.J., Hetjan, D.F., Stevenson, L.W., Dembitsky, W., Log, J.W., Ascheim, D.D., Tierney, A.R., Levitan, R.G., Watson, J.T. and Meier, P.M., 2001, "Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure," N Engl J Med, Vol. 345, pp. 1435-1443. https://doi.org/10.1056/NEJMoa012175
- Moskowitz, A.J., Weinberg, A.D., Oz, M.C. and Williams, D.L., 1997, "Quality of Life with an Implanted Left Ventricular Assist Device," Ann Thorac Surg, Vol. 64, pp. 1764-1769. https://doi.org/10.1016/S0003-4975(97)01000-X
- Saughter, M.S., Joseph, J.G., Carmano, C.A., Russell, S.D., Conte, J.V., Feldman, D., Sun, B., Tatooles, A.J., Delgado, R.M., Long, J.W., Wozniak, T.C., Ghummam, W., Farrar, D.J. and Frazier, O.H., 2009, "Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device," N Engl J Med, Vol. 361, pp. 2241-2251. https://doi.org/10.1056/NEJMoa0909938
- DeRose, J.J., Umana, J.P., Argenziano, M., Catanese, K.A., Levin, H.R., Sun, B.C., Rose, E.A. and Oz, M.C., 1997, "Improved Results for Postcardiotomy Cardiogenic Shock with the Use of Implantable Left Ventricular Assist Device," Ann Thorac Surg, Vol. 64, pp. 1757-1762. https://doi.org/10.1016/S0003-4975(97)01107-7
- Segreti, J.A., Marsh, K.C., Polakowski, J.S. and Fryer, R.M., 2008, "Evoked Changes in Cardiovascular Function in Rats by Infusion of Levosimendan, OR-1896 [(R)-N-(4- (4-Methyl-6-oxo-1,4,5,6-tetrahydropyridazin-3-yl)phenyl) acetamide], OR-1855 [(R)-6-(4 Aminophenyl)-5-methyl- 4,5-dihydropyridazin-3(2H)-one], Dobutamine, and Milrinone: Comparative Effects on Peripheral Resistance, Cardiac Output, dP/dt, Pulse Rate, and Blood Pressure," JPET, Vol. 325, pp. 331-340. https://doi.org/10.1124/jpet.107.132530
- Lietz, K.., Long, J.W., Kfoury, A.G., Slaughter, M.S., Silver, M.A., Milano, C.A., Rogers, J.G., Naka, Y., Mancini, D. and Miller, L.W., 2007, "Outcome of Left Ventricular Assist Device Implantation as Destination Therapy in the Post-REMATCH Era Implication for Patient Selection," Circulation, Vol. 116, pp. 497-505 https://doi.org/10.1161/CIRCULATIONAHA.107.691972
- Klotz, S., Deng, M.C., Stypmann, J., Roetker, J., Wilhelm, M.J., Hammel, D., Scheld, H.H. and Schmid, C., 2004, "Left Ventricular Pressure and Volume Unloading During Pulsatile Versus Nonpulsatile Left Ventricular Assist Device Support," Ann Thorac Surg, Vol. 77, pp. 143-150. https://doi.org/10.1016/S0003-4975(03)01336-5
- Feller, E.D., Sorensen, E.N., Haddad, M., Pierson, R.N., Johnson, F.L., J Brown,.M. and Griffith, B.P., 2007, "Clinical Outcomes Are Similar in Pulsatile and NonPulsatile Left Ventricular Assist Device Recipients," Ann Thorac Surg, Vol. 83, pp. 1082-1088. https://doi.org/10.1016/j.athoracsur.2006.10.034
- Fukamachi, K., Mcarthy, P.M., Smedira, N.G., Vargo, R.L., Starling, R.C. and Young, J.B., 1999, "Preoperative Risk Factors for Right Ventricular Failure After Implantable Left Ventricular Assist Device Insertion," Ann Thorac Surg, Vol. 68, pp. 2181-2184. https://doi.org/10.1016/S0003-4975(99)00753-5
- Dembitsky, W.P., Tector, A.J., Park, S., Moskowitz, A.J., Gelijns, A.C., Ronan, N.S., Piccione, W., Holman, W.L., Furukawa, S., Frazier, O.H., Weinberg, A.D., Heatley, G., Poirier, V.L., Damme, L. and Long, J.W., 2004, "Left Ventricular Assist Device Performance with Long-Term Circulatory Support: Lessons from the REMATCH Trial," Ann Thorac Surg, Vol. 78, pp. 2123-2130. https://doi.org/10.1016/j.athoracsur.2004.02.030
- Matthews, J.C., Koelling, T.M., Pagani, F.D. and Aaronson, K.D., 2008, "The Right Ventricular Failure Risk Score," J Am Coll Cardiol, Vol. 51, pp. 2163-2172. https://doi.org/10.1016/j.jacc.2008.03.009
- Potapov, E.V., Loebe, M., Nasseri, B.A., Sinawski, H., Kostr, A., Kuppe, H., Noon, G.P., Debakey, M.E. and Hetzer, R., 200, "Pulsatile Flow in Patient with a Novel NonPulsatile Implantable Ventricular Assist Device," Circulation, Vol.102, pp. 183-187. https://doi.org/10.1161/01.CIR.102.24.e183
- Leonard, E.F., 1972, "The Role of Flow in Thrombogenesis," Bull N Y Acad Med, Vol. 48(2), pp.273-280.
- Maeda, T., Tanoue, Y., Nakashima, A. and Tominaga, R., 2010, "Atypical Presentation of an Apical Pseudoaneurysm in a Patient on Prolonged Left Ventricular Mechanical Support," Thoracic Surgery, Vol. 10, pp. 350-351.
- Giridharn, G.A., Lederer, C., Berthe, A., Goubergrits, L., Hutzenlaub, J., Dowling, R.D., Spence, P.A. and Koenig, S.C., 2011, "Flow Dynamics of a Novel Counterpulsation Device Characterized by CFD and PIV Modeling," Elsevier, Vol. 10, pp. 1016-1025.
- Donovan, F.M., 1975, "Design of a Hydraulic Analog of the Circulatory System for Evaluating Artificial Heart," Artif Organs, Vol. 3, pp. 439-449.
Cited by
- Detection of Premature Ventricular Contractions on a Ventricular Electrocardiogram for Patients With Left Ventricular Assist Devices vol.38, pp.12, 2014, https://doi.org/10.1111/aor.12306
- Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device vol.38, pp.12, 2014, https://doi.org/10.3795/KSME-B.2014.38.12.971
- Biocompatibility Evaluation of Bent-Type Left Ventricular Assist Device During Long-Term Animal Experiment and Emergent Situation vol.38, pp.9, 2014, https://doi.org/10.3795/KSME-B.2014.38.9.739
- Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors vol.15, pp.1, 2016, https://doi.org/10.1186/s12938-016-0204-z
- Windkessel model of hemodynamic state supported by a pulsatile ventricular assist device in premature ventricle contraction vol.17, pp.1, 2018, https://doi.org/10.1186/s12938-018-0440-5