Abstract
We analyzed various cost components for approximately 40 small-scale island desalination plants operated by K-water. A significant factor affecting desalination cost was found, and we proposed a way to reduce desalination costs. All plants considered were reverse osmosis (RO) facilities. TDS concentrations of feed water varied from less than 1,000 mg/L (practically considered freshwater) to over 30,000 mg/L (nearly seawater). Analysis of desalination costs from 2005 to 2009 indicated that maintenance, labor, and energy were the three biggest components that accounted for 50.6%, 36.9% and 7.8%, respectively. It was well known that TDS of feed water directly affected energy needed for RO process. In this study we found that maintenance cost was also directly related to feed water TDS. This finding indicated that lowering feed water TDS might result in significant desalination cost reduction.
한국수자원공사에서 위탁 관리하고 있는 서남해안 도서지역 역삼투 해수담수화 시설 40여곳에 대한 비용 분석을 통하여 비용에 큰 영향을 미치는 요소를 찾아내고 담수화 비용 절감방안을 제시하였다. 시설에 공급되는 원수의 염도(TDS)는 담수로 취급될 수 있는 1,000mg/L 이하에서부터 해수수준인 3,000mg/L 이상까지 다양한 범위를 보이고 있다. 2005년부터 5년 동안의 비용분석 결과 유지보수비가 50.6%, 인건비가 36.9%, 그리고 에너지비가 7.8%의 순으로 나타났다. 본 연구에서는 일반적으로 잘 알려진 에너지 비용은 물론 담수화 비용의 가장 큰 비중을 차지하는 유지보수 비용도 원수의 TDS 농도에 직접적인 영향을 받고 있음을 밝혔다. 이는 원수의 TDS 농도가 담수화 비용의 60%에 달하는 부분에 영향을 끼치므로 담수화 비용 절감을 위해서는 저염도 원수 확보에 노력을 기울여야 한다는 것을 의미한다.