DOI QR코드

DOI QR Code

Position Sensor Fault Tolerant Control of Permanent Magnet Synchronous Generator

영구자석 동기발전기의 위치센서 고장 회피 제어

  • 이광운 (목포해양대 해양전자통신공학부)
  • Received : 2011.03.10
  • Accepted : 2011.05.29
  • Published : 2011.08.20

Abstract

Rotor position is essentially required for vector control of permanent magnet synchronous generator(PMSG) and position sensor such as encoder are generally used for the purpose of position sensing. However, the use of position sensor degrades reliability of PMSG control system. This paper presents position sensor fault tolerant control method for PMSG control system. Sensorless position estimator based on extended electromotive force(EMF) is operated in parallel with sensored vector control to provide rapid reconfiguration capability to sensorless vector control at the moment of position sensor fault detection. Experimental results show the effectiveness of the proposed method.

영구자석 동기발전기의 벡터제어를 위해서는 회전자 위치가 필요하며 엔코더와 같은 위치센서가 위치 검출 목적으로 일반적으로 사용되고 있다. 그러나 위치센서의 사용은 영구자석 동기전동기 제어시스템의 신뢰성을 저하시킨다. 본 논문에서는 영구자석 동기전동기 제어시스템을 위한 위치센서 고장 회피 제어 방법을 제안한다. 확장 유기전력에 기반한 센서리스 위치 추정 알고리즘을 센서를 이용하는 벡터 제어와 병렬로 수행함으로써 위치센서 고장발생 시점에서 센서리스 벡터제어로 신속히 재구성할 수 있도록 하였다. 실험을 통해 제안된 방식의 유용성을 보인다.

Keywords

References

  1. 차인수, 김태형, 이기봉, "호남광역경제권의 서남해안 풍력산업 특성", 전력전자학회 2010년도 하계학술대회 논문집, pp. 101-102, 2010. 7.
  2. 윤동근, 강이규, 정해광, 이교범, "대용량 영구자석형 풍력발전시스템의 3병렬 운전을 위한 LCL필터 설계", 전력전자학회 2009년도 하계학술대회 논문집, pp. 606-608, 2009. 7.
  3. 장석호, 박홍극, 이동춘, 김흥근, "소형 풍력발전용 영구자석형 동기발전기의 센서리스 제어", 전력전자학회 논문지, 제14권, 제1호, pp. 15-22, 2009.
  4. S. Morimoto, K. Kawamotor, M. Sanada, and Y. Takeda, "Sensorless control strategy for salient-pole PMSM based on extended EMF in rotating reference frame", IEEE Trans. Ind. Appl., Vol. 38, No. 4, pp. 1054-1061, 2002. https://doi.org/10.1109/TIA.2002.800777
  5. H. Kim, M.C. Harke, and R. D. Lorenz, "Sensorless control of interior permanent-magnet machine drives with zero-phase lag position estimation", IEEE Trans. Ind. Appl., Vol. 39, No. 6, pp. 1726-1733, 2003. https://doi.org/10.1109/TIA.2003.818966
  6. S. Ichikawa, M. Tomita, S. Doki, and S. Okuma, "Sensorless control of synchronous reluctance motors based on extended EMF models considering magnetic saturation with online parameter identification", IEEE Trans. Ind. Appl., Vol 42., No. 5, pp. 1264-1274, 2006. https://doi.org/10.1109/TIA.2006.880848
  7. K. Rothenhagen, and F. W. Fuchs, "Doubly fed induction generator model-based sensor fault detection and control loop reconfiguration", IEEE Trans. Ind. Electron., Vol. 56, No. 10, pp. 4229-4283, 2009. https://doi.org/10.1109/TIE.2009.2013683

Cited by

  1. Hall Sensor Fault Detection and Fault-Tolerant Control of High-Speed PMSM Drive System vol.18, pp.3, 2013, https://doi.org/10.6113/TKPE.2013.18.3.205
  2. Sensorless Control Method in IPMSM Position Sensor Fault for HEV vol.8, pp.5, 2013, https://doi.org/10.5370/JEET.2013.8.5.1056