References
- MKE/KEEI, 2008, Yearbook of Energy Statics, Report of Ministry of Knowledge Economy/Korea Energy Economics Institute, ISSN 1226-606X.
- Kavanaugh, S. P. and Rafferty, K., 1997, Ground- Source Heat Pumps:Design of Geothermal Systems for Commercial and Institutional Buildings, American Society of Heating, Refrigerating and Air-conditioning Engineers(ASH RAE), Atlanta, US.
- Eskilson, P., 1987, Thermal analysis of heat extraction boreholes, Doctoral thesis, University of Lund, Sweden.
- Pahud, D. and Hellstrom, G., 1996, The new duct ground model for TRNSYS, Eurotherm Seminar, Eindhoven, Netherlands, Vol. 49 pp. 127-136.
- Yavuzturk, C. and Spitler, J. D., 1999, A short time step response factor model for vertical ground loop heat exchangers, ASHRAE Transactions, Vol. 105, pp. 475-485.
- Yavuzturk, C. and Spitler, J. D., 2001, Field validation of a short time step model for vertical ground loop heat exchangers, ASHRAE Transactions, Vol. 107, pp. 617-625.
- Akpinar, E. K. and Hepbasli, A., 2007, A comparative study on exergetic assessment of two ground-source(geothermal) heat pump systems for residential applications, Building and Environment, Vol. 42, pp. 2004-2013. https://doi.org/10.1016/j.buildenv.2006.04.001
- Sohn, B. H., Cho, C. S., Shin, H. J. and An, H. J., 2005, Cooling and heating performance evaluation of a GSHP system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 71-81.
- Kim, B. S., 2009, The energy performance analysis of ground heat sources heat pump system installed in green home, Journal of the Architectural Institute of Korea, Vol. 25, No. 9, pp. 339-346.
- Shonder, J. A., Baxter, V., Thornton, J. and Hughes, P., 1999, A new comparison of vertical ground heat exchanger design methods for residential applications, ASHRAE Transactions, Vol. 105, pp. 1179-1188.
- Remund, C. P., 1999, Borehole thermal resistance : laboratory and field studies, ASHRAE Transactions, Vol. 105, pp. 439-445.
Cited by
- Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger vol.24, pp.3, 2012, https://doi.org/10.6110/KJACR.2012.24.3.230
- Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy vol.36, pp.4, 2012, https://doi.org/10.5916/jkosme.2012.36.4.437
- An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System vol.25, pp.3, 2013, https://doi.org/10.6110/KJACR.2013.25.3.156
- Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building vol.26, pp.9, 2014, https://doi.org/10.6110/KJACR.2014.26.9.409
- Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House vol.28, pp.10, 2016, https://doi.org/10.6110/KJACR.2016.28.10.387