References
- D. M. McDonald and P. L. Choyke, "Imaging of angiogenesis: from microscope to clinic," Nature Medicine 9, 713-725 (2003). https://doi.org/10.1038/nm0603-713
- W.-H. Kim, C.-I. Kim, S.-W. Lee, S.-H. Lim, C.-W. Park, H. Lee, and M.-K. Park, "Particle image velocimetry of the blood flow in a micro-channel using the confocal laser scanning microscope," J. Opt. Soc. Korea 14, 42-48 (2010). https://doi.org/10.3807/JOSK.2010.14.1.042
- A. A. Tanbakuchi, A. R. Rouse, J. A. Udovich, K. D. Hatch, and A. F. Gmitro, "Clinical confocal microlaparoscope for real-time in vivo optical biopsies," Journal of Biomedical Optics 14, 044030-044012 (2009). https://doi.org/10.1117/1.3207139
- J. Tan, M. Quinn, J. Pyman, P. Delaney, and W. McLaren, "Detection of cervical intraepithelial neoplasia in vivo using confocal endomicroscopy," BJOG: An International Journal of Obstetrics & Gynaecology 116, 1663-1670 (2009). https://doi.org/10.1111/j.1471-0528.2009.02261.x
- K. B. Sung, C. N. Liang, M. Descour, T. Collier, M. Follen, and R. Richards-Kortum, "Fiber-optic confocal reflectance microscope with miniature objective for in vivo imaging of human tissues," IEEE Transactions on Biomedical Engineering 49, 1168-1172 (2002). https://doi.org/10.1109/TBME.2002.803524
- E. J. Seibel, R. S. Johnston, C. M. Brown, J. A. Dominitz, and M. B. Kimmey, "Novel ultrathin scanning fiber endoscope for cholangioscopy and pancreatoscopy," Gastrointestinal Endoscopy 65, Ab125 (2007).
- P. Kim, M. Puoris'haag, D. Côté, C. P. Lin, and S. H. Yun, "In vivo confocal and multiphoton microendoscopy," Journal of Biomedical Optics 13, 010501 (2008).
- W. Gobel, J. N. D. Kerr, A. Nimmerjahn, and F. Helmchen, "Miniaturized two-photon microscope based on a flexible coherent fiber bundle and a gradient-index lens objective," Opt. Lett. 29, 2521-2523 (2004). https://doi.org/10.1364/OL.29.002521
- C.-S. Rim, "The optical design of probe-type microscope objective for intravital laser scanning CARS microendoscopy," J. Opt. Soc. Korea 14, 431-437 (2010). https://doi.org/10.3807/JOSK.2010.14.4.431
- M. D. Chidley, K. D. Carlson, R. R. Richards-Kortum, and M. R. Descour, "Design, assembly, and optical bench testing of a high-numerical-aperture miniature injection-molded objective for fiber-optic confocal reflectance microscopy," Appl. Opt. 45, 2545-2554 (2006). https://doi.org/10.1364/AO.45.002545
- J. M. Sasian and M. R. Descour, "Power distribution and symmetry in lens systems," Opt. Eng. 37, 1001-1004 (1998). https://doi.org/10.1117/1.601933
- D. Ren and J. R. Allington-Smith, "Apochromatic lenses for near-infrared astronomical instruments," Opt. Eng. 38, 537-542 (1999). https://doi.org/10.1117/1.602131
- W. Piyawattanametha and T. D. Wang, "MEMS-based dual-axes confocal microendoscopy," IEEE J. Select. Topics Quantum Electron. 16, 804-814 (2010). https://doi.org/10.1109/JSTQE.2009.2032785
- L. Fu and M. Gu, "Fibre-optic nonlinear optical microscopy and endoscopy," Journal of Microscopy-Oxford 226, 195-206 (2007). https://doi.org/10.1111/j.1365-2818.2007.01777.x
Cited by
- Forming a Fresnel Zone Lens: Effects of Photoresist on Digital-micromirror-device Maskless Lithography with Grayscale Exposure vol.16, pp.2, 2012, https://doi.org/10.3807/JOSK.2012.16.2.127