Abstract

In this study, a new method that can estimate ICG data from a subject's both hands to measure Cardiac Output under convenient sensor environment. With this aim, a grip-type electrode was implemented to measure ICG. To improve the accuracy of measurement, the regression equation was extracted using multiple bio-parameters and our result was compared with the thoracic ICG equipment(Physio Flow$^{(R)}$, PF104D, Manatec Biomedical, France), which is being used in clinics. The subjects consist of 26 men and 4 women(age in $22.0{\pm}3.32$). They are no cardiac disease. Parameters available for regression model were used gender, BMI, MBP, LVET, dZ/dt(max), distance between the measured electrodes, body impedance, and PTT. As a result of analyzing the ICG measurement value on thorax and both hands, the correlation with stroke volume, heart rate, and cardiac output was $R^2$=0.853, $R^2$=0.958 and $R^2$=0.899, respectively.

Keywords

References

  1. Martinez I., Fernandez J., Galarraga M., Serrano L., De Toledo P., Jimenez-Fernandez S., Led S., M. Martinez-Espronceda, Garcia J., "Implementation of an end-to-end standard-based patient monitoring solution," Institution Engineering and Technology Communications, Vol.2, pp. 181-191, 2008.
  2. Lee R.G., Lai C.C., Chiang S.S., Liu H.S., Chen C.C., Hsieh G.Y., "Design and implementation of a mobile-care system over wireless sensor network for home healthcare applications," Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, no.4029238, pp. 6004-6007, 2006.
  3. S.M. Lee, "Cardiac Output Measurement," Korean J. Anesthesiol Vol.46, No.1, pp. 1-9, 2004. https://doi.org/10.4097/kjae.2004.46.1.1
  4. W.S. Ahn, "Problens in Cardiac Output Measurement and Clinical Understanding," Korean J. Anesthesiol, Vol.54, No.3, pp. 241-55, 2008. https://doi.org/10.4097/kjae.2008.54.3.241
  5. Kubicek W.G., Kottke F.J., Ramos M.U., Patterson R.P., Witsoe D.A., Labree J.W., Remole W., Layman T.E., Schoening H. and Garamela J.T., "The Minnesota impedance cardiograph - theory and applications," Bimed. Eng., Vol.9, No.9, pp. 410-6, 1974.
  6. Thomas A.N., Ryan J., Doran B.R.H. and Pollard B.J., "Bioimpedance versus thermodilution cardiac output measurement : the Bomed NCCOM3 after coronary bypass surgery," Intensive Care Med., Vol.17, pp. 383-386, 1991. https://doi.org/10.1007/BF01720674
  7. Charloux A., Lonsdorfer-Wolf E., Richard R., Lampert E., Mammosser M.O., Mettauer B., Geny B. and Lonsdorfer J., "A New Impedance Cardiograph Device for the Non-invasive Evaluation of Cardiac Output at Rest and During Exercise : Comparison with the "Direct" Fick Method," European Journal of Applied Physiology, Vol.82, No.4, pp. 313-320, 2000. https://doi.org/10.1007/s004210000226
  8. Lepretre J.M., Koralsztein J.P. and Billat V.L., "Effect of Exercise Intensity on Relationship between VO2max and Cardiac Output," Med. Sci. Sports Exerc., Vol.36, No.8, pp. 1357-1363, 2004. https://doi.org/10.1249/01.MSS.0000135977.12456.8F
  9. Tordi T., Mourot L., Matusheski B., Hughson R.L., "Measurements of Cardiac Output during Constant Exercises : Comparison of Two Non-Invasive Techniques," Int J. Sports Med., Vol.25, pp. 145-149, 2004. https://doi.org/10.1055/s-2004-819949