Abstract
This study was conducted to assess the vibration capacity and the fire resistance capacity of a deck plate slab using an omega steel plate as the void deck plate. First, to evaluate the vibration capacity of the deck plate slab after the insertion of the omega steel plate, three 150mm specimens and three 200mm specimens were made using the slab depth as the main variable. Each specimen consisted of an existing deck plate and two specimens, using the topping depth as the variable according to the slab depth. Second, two real-size specimens were made to evaluate the fire resistance capacity. The results of the test showed that the steel-wire-integrated deck plate slab that was inserted in the omega steel plate did not have a vibration problem due to the void deck plate, because the natural frequency was 12.66-14.09 Hz in the vibration test, and each specimen satisfied the appraisal standards for the load capacity, heat block quality, and chloride inhibition for two hours in the fire resistance test. Consequently, the steel-wire-integrated deck plate slab that was inserted in the omega steel plate can be reduced using the concrete volume and can have higher vibration and fire resistance capacities, similar to the existing deck plate.
본 연구의 목적은 기존의 데크플레이트 슬래브에 오메가형 강판을 중공체로 사용한 데크플레이트 슬래브의 진동 및 내화성능을 평가하는 것이다. 오메가형 강판의 삽입으로 인한 데크플레이트 슬래브의 진동 성능을 평가하기 위해서 슬래브 두께를 주요 변수로 하였으며, 각각 150mm 실험체 3개와 200mm 실험체 3개를 제작하였다. 각 실험체는 슬래브 두께별로 기존의 데크플레이트 슬래브 1개와 콘크리트 토핑두께(오메가형 강판의 높이)를 변수로 하는 2개의 실험체로 구성되어 있다. 또한 내화성능을 평가하기 위해서 실물크기의 실험체 2개(동일 크기)를 제작하였다. 진동에 대한 실험결과 오메가형 강판이 삽입된 철선일체형 데크플레이트 슬래브는 고유진동수가 12.66Hz~14.09Hz로써 중공부로 인한 진동문제는 없는 것으로 나타났다. 또한 내화성능에 대한 실험 결과 각 실험체는 실험시간 2시간 동안 하중지지력, 차열성, 차염성에 대한 평가기준을 모두 만족하였다. 따라서 오메가형 강판을 삽입한 철선일체형 데크플레이트는 효과적으로 콘크리트 사용량을 저감하면서도 기존의 데크플레이트에 준하는 진동 및 내화성능을 갖춘 것으로 판단된다.