Abstract
Heating pipes, which are among the main equipment in district heating systems, can be classified into supply and return pipes. Because when the district heating transmission pipe, which is charged with district heating in small to medium-size cities, is under thermal stress during temperature variances in heating water, it suffers from the fatigue phenomenon caused by the thermal stress, according to the number of its service years. District heatingpipes have shown various characteristics according to the operating condition of the service connections, and the irregular temperature variance has had a bad influence on fatigue heating pipes. Therefore, in this study, a field test on laid heating pipes was performed, and the data for each region were analyzed. Also, the fatigue safety of district heating pipes was evaluated via cycle-based evaluation and stress-based evaluation.
지역난방 시스템의 주요 구성요소의 하나인 열배관은 크게 공급관과 회수관으로 구분되며, 지역난방에서의 열수송 배관은 난방수의 온도변화에 따른 열응력을 받게 되므로 공용년수 증가에 따라 열응력에 의한 피로현상이 발생하게 된다. 한편 지역난방 열배관은 사용자배관의 공용조건에 따라 다양한 특성을 나타내며 이러한 불규칙한 온도변화는 열배관의 피로에 악영향을 미치게 된다. 따라서 본 연구에서는 기 매설된 공용중인 지역별 열배관에 대해 현장계측을 실시하고 각 지역의 데이터를 분석하였다. 또한 사이클기반 피로평가법 및 응력기반 피로평가법을 통하여 지역난방 열배관의 피로안전성을 평가하였다.