DOI QR코드

DOI QR Code

고주파 절제술을 위한 심장전극도자 원격 제어 로봇 플랫폼의 개발

Development of a Cardiac Catheter Remote Control Robot Platform for Radiofrequency Ablation Intervention

  • 박준우 (고려대 의대 의공학교실, 고려대 의대 한국인공장기센터) ;
  • 송승준 (고려대 의대 협동과정의생체공학) ;
  • 이정찬 (서울대 의학연구원 의용생체공학연구소) ;
  • 최혁 (고려대 구로병원 의료기기임상시험센터) ;
  • 이정주 (고려대 의대 한국인공장기센터) ;
  • 최재순 (고려대 의대 한국인공장기센터)
  • 투고 : 2010.11.24
  • 심사 : 2011.05.11
  • 발행 : 2011.07.01

초록

Radiofrequency ablation through cardiac catheterization is one of minimally invasive intervention procedures used in drug resistant arrhythmia treatment. To facilitate more accurate and precise catheter navigation, systems for robotic cardiac catheter navigation have been developed and commercialized. The authors have been developing a novel robotic catheter navigation system. The system is a network-based master-slave configuration 3-DOF (Degree-Of-Freedom) robotic manipulator for operation with conventional cardiac ablation catheter. The catheter manipulation motion is composed of the translation (forward/backward) and the roll movements of the catheter and knob rotation for the catheter tip articulation. The master manipulator comprises an operator handle compartment for the knob and the roll movement input, and a base platform for the translation movement input. The slave manipulator implements a robotic catheter platform in which conventional cardiac catheter is mounted and the 3-DOF motions of the catheter are controlled. The system software that runs on a realtime OS based PC, implements the master-slave motion synchronization control in the robot system. The master-slave motion synchronization performance tested with step, sinusoidal and arbitrarily varying motion commands showed satisfactory results with acceptable level of steady state error. The developed system will be further improved through evaluation of safety and performance in in vitro and in vivo tests.

키워드

참고문헌

  1. W. B. Kannel, R. D. Abbott, D. D. Savage, and P. M. McNamara, "Epidemiologic Features of Chronic Atrial Fibrillation: The Framingham Study," N Engl J Med, vol. 306, No. 17, pp.1018-1022, April 1982. https://doi.org/10.1056/NEJM198204293061703
  2. P. Dario, E. Guglielmelli, B. Allotta, and M. C. Carrozza, "Robotics for Medical Applications," IEEE Robot. Autom. Mag., vol. 3, No. 3, pp.44-56, September 1996. https://doi.org/10.1109/100.540149
  3. S. Y. Ko and D. S. Kwon, "The Force Feedback Method for Master/Slave-Combined System," Int. Conf. on Control, Automation and Systems, 2001.
  4. E Marcelli, L Cercenelli, and G Plicchi, "A Novel Telerobotic System to Remotely Navigate Standard Electrophysiology Catheters," Comput. Cardiol., vol. 35, No. 1, pp.137-140, January 2008.
  5. N. Simaan, K. Xu, W. Wei, A. Kapoor, P. Kazanzides, R. Taylor, and P. Flint, "Design and Integration of a Telerobotic System for Minimally Invasive Surgery of the Thoat," Int. J. Robot. Res., vol. 28, No. 9, pp.1134-1153, September 2009. https://doi.org/10.1177/0278364908104278
  6. C. R. Tercero, Seiichi Ikeda et al., "Catheter Insertion Mechanism and Feedback Control using Magnetic Motion Capture Sensor," SICE-ICASE Int. Joint Conf., pp.1856-1859, 2006.
  7. C. R. Tercero, S. Ikeda, T. Fukuda, K. Sekiyama, Y. Okada, T. Uchiyama, M. Negoro, and I. Takahashi, "Catheter Insertion Path Reconstruction with Autonomous System for Endovascular Surgery," IEEE Int. Symp. on Computational Intelligence in Robotics and Automation, pp.398-403, 2007.
  8. F. Araf, R. Fuji, T. Fukuda, and M. Negoro, "New Catheter Driving Method Using Linear Stepping Mechanism for Intravascular Neurosurgery," IEEE Int. Conf. Robot., pp.2944-2949, 2002.
  9. F. Araf, M. Tanimoto, T. Fukuda, I. shimojma, H. Matsuurq, and M. Negoro, "Multimedia Tele-surgery Using Hight Speed Option Fiber Network and Its Application to Intravasular Neurosurgery," IEEE Int. Conf. Robot., pp.878-883, 1996.
  10. L. Cercenelli, E. Marcelli E, and G. Plicchi, "Initial Experience With a Telerobotic System to Remotely Navigate and Automatically Reposition Standard Steerable EP Catheters," ASAIO J, vol. 53, No. 5, pp.523-529, May 2007. https://doi.org/10.1097/MAT.0b013e3181484cd0
  11. J. Jayender and R. V. Patel, "Master-Slave Control of an Active Catheter Instrumented with Shape Memory Alloy Actuators," IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.759-764, 2007.
  12. Y. Ganji and F. Janabi-Sharifi, "Kinematic Characterization of a Cardiac Ablation Catheter," IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, pp.1876-1881, 2007.
  13. A. Al-Ahmad, J. D. Grossman, and P. J. Wang, "Early Experience with Computerized Robotically Controlled Catheter System," J. Interv. Card. Electr., vol. 12, No. 3, pp.199-202, March 2005. https://doi.org/10.1007/s10840-005-0325-y
  14. N. Marrouche and J. Brachmann, "Preliminary Human Experience Using a Novel Robotic Catheter Remote Control," Heart Rhythm, vol. 2, No. 5, p.s63, May 2005.
  15. Y. Thakur, J. S. Bax, D. W. Holdsworth, and M. Drangova, "Design and Performance Evaluation of a Remote Catheter Navigation System," IEEE T. Bio-Med. Eng, vol. 56, No. 7, pp.1901-1908, July 2009. https://doi.org/10.1109/TBME.2009.2017203
  16. S. B. Kesner and R. D. Howe, "Design and Control of Motion Compensation Cardiac Catheters," IEEE Int. Conf. Robot., pp.1059-1065, 2010.
  17. M. N. Faddis, W. Blume, J. Finney, A. Hall, J. Rauch, J. Sell, K. T. Bae, M. Talcott, and B. Lindsay, "Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation," Circulation, vol. 106, pp.2980-2985, December 2002. https://doi.org/10.1161/01.CIR.0000038704.84304.6F
  18. S. Ernst, F. Ouyang, C. Linder, K. Hertting, F. Stahl, J. Chun, H. Hachiya, D. Bansch, M. Antz, and K-H. Kuck, "Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation System: Magnetic Remote Catheter Ablation," Circulation, vol. 109, pp.1472-1475, March 2004. https://doi.org/10.1161/01.CIR.0000125126.83579.1B