DOI QR코드

DOI QR Code

The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Kim, Seong-Kyun (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Lee, Shin-Jae (Department of Orthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Lee, Joo-Hee (Department of Prosthodontics, Asan Medical Center, College of Medicine, University of Ulsan)
  • 투고 : 2011.04.05
  • 심사 : 2011.04.27
  • 발행 : 2011.06.30

초록

PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

키워드

참고문헌

  1. Esposito M, Grusovin MG, Willings M, Coulthard P, Worthington HV. Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev 2007;2:CD003878.
  2. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
  3. Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28:266-72. https://doi.org/10.1016/S0901-5027(99)80156-8
  4. Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12-25. https://doi.org/10.1034/j.1600-0501.2000.011001012.x
  5. Kim SK, Heo SJ, Koak JY, Lee JH, Kwon JY. Development of predictable stability test for assessment of optimum loading time in dental implant. J Korean Acad Prosthodont 2008;46:628-33. https://doi.org/10.4047/jkap.2008.46.6.628
  6. Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: an experimental study in the dog mandible. Clin Implant Dent Relat Res 2001;3:2-8. https://doi.org/10.1111/j.1708-8208.2001.tb00123.x
  7. Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15:529-39. https://doi.org/10.1111/j.1600-0501.2004.01042.x
  8. Heo SJ, Sennerby L, Odersjo M, Granstrom G, Tjellstrom A, Meredith N. Stability measurements of craniofacial implants by means of resonance frequency analysis. A clinical pilot study. J Laryngol Otol 1998;112:537-42.
  9. Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26:275-91. https://doi.org/10.1615/CritRevBiomedEng.v26.i4.20
  10. Sim CP, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants Res 2010;21:598-604. https://doi.org/10.1111/j.1600-0501.2009.01878.x
  11. Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A crosssectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8:226-33. https://doi.org/10.1034/j.1600-0501.1997.080309.x
  12. Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997;8:234-43. https://doi.org/10.1034/j.1600-0501.1997.080310.x
  13. Sennerby L, Persson LG, Berglundh T, Wennerberg A, Lindhe J. Implant stability during initiation and resolution of experimental periimplantitis: an experimental study in the dog. Clin Implant Dent Relat Res 2005;7:136-40. https://doi.org/10.1111/j.1708-8208.2005.tb00057.x
  14. Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47:51-66. https://doi.org/10.1111/j.1600-0757.2008.00267.x
  15. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7. https://doi.org/10.1034/j.1600-0501.1996.070308.x
  16. Nkenke E, Hahn M, Weinzierl K, Radespiel-Troger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res 2003;14:601-9. https://doi.org/10.1034/j.1600-0501.2003.00937.x
  17. Schliephake H, Sewing A, Aref A. Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomorphometric data. Int J Oral Maxillofac Surg 2006;35:941-6. https://doi.org/10.1016/j.ijom.2006.05.002
  18. Alsaadi G, Quirynen M, Michiels K, Jacobs R, van Steenberghe D. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment. J Clin Periodontol 2007;34:359-66. https://doi.org/10.1111/j.1600-051X.2007.01047.x
  19. Lee SY, Koak JY, Heo SJ, Kim SK, Lee SJ, Nam SY. Osseointegration of anodized titanium implants coated with poly(lactide-co-glycolide)/basic fibroblast growth factor by electrospray. Int J Oral Maxillofac Implants 2010;25:315-20.
  20. Yoon HI, Yeo IS, Yang JH. Effect of a macroscopic groove on bone response and implant stability. Clin Oral Implants Res 2010;21:1379-85. https://doi.org/10.1111/j.1600-0501.2010.01960.x
  21. Donath K, Breuner G. A method for the study of undecalcified bones and teeth with attached soft tissues. The Sage-Schliff (sawing and grinding) technique. J Oral Pathol 1982;11:318-26. https://doi.org/10.1111/j.1600-0714.1982.tb00172.x
  22. Bliese P. Multilevel Modeling in R (2.3). A Brief Introduction to R, the multilevel package and the nlme package. Retrieved February 13, 2009. from http://www.R-project.org.
  23. Gedrange T, Hietschold V, Mai R, Wolf P, Nicklisch M, Harzer W. An evaluation of resonance frequency analysis for the determination of the primary stability of orthodontic palatal implants. A study in human cadavers. Clin Oral Implants Res 2005;16:425-31. https://doi.org/10.1111/j.1600-0501.2005.01134.x
  24. Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments. Clin Oral Implants Res 2008;19:9-14.
  25. Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone 2005;37:776-80. https://doi.org/10.1016/j.bone.2005.06.019

피인용 문헌

  1. The effect of systemically administrated zoledronic acid on the osseointegration of dental implants vol.18, pp.8, 2012, https://doi.org/10.1111/j.1601-0825.2012.01948.x
  2. Bone formation and osseointegration with titanium implant using granular- and block-type porous hydroxyapatite ceramics (IP-CHA) vol.32, pp.5, 2013, https://doi.org/10.4012/dmj.2012-169
  3. New Insight Into Baha® Implant Stability Measurements vol.34, pp.6, 2013, https://doi.org/10.1097/MAO.0b013e31827e5fc4
  4. Transalveolar sinus floor elevation using osteotomes without grafting in severely atrophic maxilla: a 5-year prospective study vol.27, pp.1, 2016, https://doi.org/10.1111/clr.12547
  5. In vivo monitoring of implant osseointegration in a rabbit model using acoustic sound analysis vol.32, pp.4, 2014, https://doi.org/10.1002/jor.22574
  6. Osseointegration of the titanium implant coated with rhTGF-β2/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study vol.52, pp.4, 2014, https://doi.org/10.4047/jkap.2014.52.4.298
  7. Influence of Implant Surfaces on Osseointegration: A Histomorphometric and Implant Stability Study in Rabbits vol.26, pp.5, 2015, https://doi.org/10.1590/0103-6440201300411
  8. histologic and biomechanical study vol.27, pp.11, 2016, https://doi.org/10.1111/clr.12756
  9. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study vol.28, pp.10, 2016, https://doi.org/10.1111/clr.12945
  10. Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia vol.46, pp.3, 2016, https://doi.org/10.5051/jpis.2016.46.3.176
  11. Effect of implant length on the stability and osseointegration of immediate implant vol.7, pp.2, 2016, https://doi.org/10.1097/01.OMX.0000481452.49607.ad
  12. Implant Stability in the Posterior Maxilla: A Controlled Clinical Trial vol.2017, pp.2314-6141, 2017, https://doi.org/10.1155/2017/6825213
  13. Investigation of a Passive Sensor Array for Diagnosis of Loosening of Endoprosthetic Implants vol.13, pp.1, 2012, https://doi.org/10.3390/s130100001
  14. Resonance Frequency Analysis of Dental Implants With 2 Types of Surface Treatment Submitted to Immediate Loading vol.27, pp.3, 2018, https://doi.org/10.1097/ID.0000000000000764
  15. Evaluation of postoperative dental implant primary stability using 3D finite element analysis pp.1476-8259, 2019, https://doi.org/10.1080/10255842.2018.1552682
  16. Modified Disk-Up Sinus Reamer for Sinus Floor Elevation and Simultaneous Implant Placement: An Animal Study with Miniature Pigs pp.1521-0553, 2019, https://doi.org/10.1080/08941939.2018.1545881
  17. Resonance Frequency Analysis and Early Loading of Implants with Sealed UV Treatment System: Case Reports vol.21, pp.2, 2011, https://doi.org/10.12972/implantology.20170009
  18. A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT vol.13, pp.6, 2011, https://doi.org/10.1371/journal.pone.0199362
  19. Comparative evaluation of implant stability in two different implant systems at baseline and 3-4 months intervals using RFA device (OSSTELL ISQ) vol.30, pp.5, 2019, https://doi.org/10.4103/ijdr.ijdr_446_17
  20. The Bone Buttress Theory: The Effect of the Mechanical Loading of Bone on the Osseointegration of Dental Implants vol.10, pp.1, 2011, https://doi.org/10.3390/biology10010012
  21. Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size vol.18, pp.13, 2021, https://doi.org/10.3390/ijerph18136994
  22. Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: A prospective pilot cohort study vol.23, pp.5, 2011, https://doi.org/10.1111/cid.13031
  23. Laser resonance frequency analysis of pedicle screw stability: A cadaveric model bone study vol.39, pp.11, 2011, https://doi.org/10.1002/jor.24983
  24. Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis vol.32, pp.11, 2011, https://doi.org/10.1111/clr.13835