Abstract
In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (steel plate, carbon fiber sheet, and embedded carbon fiber rod) in existing reinforced concrete buildings. Six specimens of retrofitted beam-column joints are constructed using various retrofitting materials and tested for their retrofit performances. Specimens designed by retrofitting the beam-column joint regions (LBCJ series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of crack control at the time of initial loading and confinement from retrofitting materials during testing. Specimens of LBCJ series, designed by the retrofitting of FRP in reinforecd beam-column joint regions increased its maximum load carrying capacity by 26~50% and its energy dissipation capacity by 13.0~14.4% when compared to standard specimen of LBCJC with a displacement ductility of 4.
이 연구에서는 기존 철근콘크리트 건물의 보-기둥 접합부 및 내진 성능의 개선을 위해 보-기둥 접합부 영역을 기존의 강판 및 FRP보강재(탄소섬유 쉬트, 매입형 탄소섬유봉)를 사용하여 보강한 후 내진 성능을 평가 하였다. 총 6개의 실험체를 제작하고 실험을 수행하여 내진 성능을 평가하였으며, 이 연구의 실험 결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역(LBCJ 시리즈)를 보강한 결과 초기 재하시 접합부 영역의 균열 억제 효과와 재하 전 과정을 통하여 보강재의 구속 효과로 인하여 균열 억제 효과가 커서 안정적인 파괴 형태 및 내력 향상 효과를 나타내었다. 기존 철근콘크리트 보-기둥 접합부의 내진 성능을 개선하기 위하여 철근콘크리트 보-기둥 접합부 FRP보강 기술 적용 실험체 LBCJ 시리즈는 표준실험체 LBCJC와 비교하여 최대 내력은 26~50% 증가하였다. 그리고 에너지 소산 능력은 변위 연성 4에서 13.0~14.4% 증가하였다.