Abstract
In a previous research performed by the authors, the allowable compressive stress coefficient (K) in pretensioned members with rectangular section at transfer was proposed based on strength design theory. In this study, a subsequent research of an enormous analysis was performed to determine the K factor for Tee and inverted Tee section members, considering the effect of section height (h), section type, amount of tendons ($A_{ps}$), and eccentricity ratio (e/h). Based on the analysis results, the allowable compressive stress coefficients (K) for Tee and inverted Tee section members at transfer were derived, which limit the maximum allowable stresses as 80% and 70% of the compressive strengths at the time of release for Tee section and inverted Tee section, respectively. And these were larger than the allowable stresses specified in domestic and other international codes. In order to verify the proposed equations, they were compared to the test results available in literature and other codes, which showed that the allowable stresses in domestic and international codes are unconservative for the cases with low eccentricity ratios while conservative for those with high eccentricity ratios. The proposed equations, however, estimate the allowable stresses of the Tee and inverted Tee section members reasonably close to test results.
이 연구의 선행 연구에서는 강도 이론을 바탕으로 장방형 단면을 갖는 프리텐션 부재의 허용 압축응력 계수 산정식을 제안하였다. 이 연구에서는 프리스트레스 도입시 T형 단면 및 역T형 단면을 갖는 프리텐션 부재의 허용 압축응력 계수를 결정하기 위하여 선행 연구에서 적용한 강도 이론을 바탕으로 단면의 크기, 단면 형상, 긴장재량 및 편심비를 고려한 방대한 해석을 수행하였다. 해석 결과를 바탕으로 허용 압축응력 계수 산정식을 유도하였으며, 제안된 산정식은 프리스트레스 도입시 허용 압축응력을 T형 및 역T형 단면에서 각각 당시 콘크리트 압축강도의 80% 및 70%로 제한하였고 이는 기존의 설계기준들에서 제공하는 값보다 높은 수치였다. 제안식을 검증하기 위하여 기존의 수행된 실험 결과 및 각국의 설계기준과 비교한 결과, 낮은 편심비에서 국내 외 기준은 비안전측의 결과를, 높은 편심비에서는 오히려 과도하게 안전측의 결과를 제공할 수 있는 것으로 나타났으며, 이에 비해 제안식은 T형 및 역 T형단면을 갖는 프리텐션 부재의 허용 압축응력을 매우 합리적으로 평가하였다.