Abstract
In this study, computation method of tensile load which develops in tie-bar of reinforced earth, connection strength between tie-bar and eco-block and shear strength of the interface between two eco-blocks were verified by experiments. According to the test results of connection strength test, peak tensile load of D13 deformed bar were close to allowable tensile load of it for situation of infill with soil. Connection strengths of D10 and D13 deformed bars were greater than the allowable tensile load of those respectively for situation of infill with concrete. According to the test results of shear strength of the interface between two eco-blocks, shear resistance parameters, ${\alpha}_u$ and ��${\lambda}_u$ were evaluated as 1.7kN/m and 2$27.6^{\circ}$ respectively.
본 연구에서는 생태축조블록을 적용한 보강토 옹벽의 국부적 안정성 검토에 필요한 보강재 인장력 계산법을 정립하고 국부적 안정성 검토와 관련한 주요 설계인자인 보강재와 블록 사이의 연결강도와 블록 접촉면 사이의 전단강도를 시험을 통해 규명하였다. 연결강도 시험결과에 따르면 생태축조블록의 내부를 흙으로 속채움하고 D13 이형철근을 사용할 경우 첨두 하중값은 이형철근의 허용인장력 정도임을 알 수 있었으며 D16 이형철근을 사용할 경우 첨두하중값은 허용인장력의 76% 정도였다. 생태축조블록의 내부를 콘크리트로 속채움하는 경우에 있어서 D10, D13 이형철근을 사용하였을 때의 연결강도는 각각의 이형철근의 허용인장력보다 크게 나타났다. 생태축조블록의 접촉면 전단시험결과를 통해 구한 전단저항 매개변수인 ${\alpha}_u$는 1.7kN/m 이었고 ${\lambda}_u$는 $27.6^{\circ}$ 이었다.