초록
Objectives : The pulse diagnosis is an important method in Oriental Medicine. The aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by pulse diagnosis apparatus using Hwang-Je (HJ) pulse analyser, Hui-Su (HS) pulse analyser on Chon, Kwan and Chuk. Methods : Four korean medical doctors and HJ pulse analyser, HS pulse analyser have measured the speed (遲數), the size (微細弱緩大), and the depth (浮沈) of pulse waves of 23 volunteers. First, four korean medical doctors measured pulse waves of volunteers. And then, the pulse waves of volunteers were measured by HJ pulse analyser, HS pulse analyser. This was performed on the right Chon, Kwan and Chuk. Results : The traditional method and the HJ pulse analyser method had the 60.9% matches on the values of the pulse speed condition, the HS pulse analyser method had the 78.3% matches on the values of the pulse speed condition. The traditional method and the HJ pulse analyser method had the 56.5% (Chon), 65.2% (Kwan), 78.3% (Chuk) matches on the values of the pulse size condition, the HS pulse analyser method had the 65.2% (Chon), 13.0% (Kwan), 39.1% (Chuk) matches on the values of the pulse size condition. The traditional method and the HJ pulse analyser method had the 43.5% (Chon), 26.1% (Kwan), 47.8% (Chuk) matches on the values of the pulse depth condition, the HS pulse analyser method had the 45.5% (Chon), 30.4% (Kwan), 36.8% (Chuk) matches on the values of the pulse depth condition. Conclusions : According to these results, we suggest that the pulse analyser is necessary to develope for its high similarities with the traditional pulse diagnosis.