DOI QR코드

DOI QR Code

Active Frequency with a Positive Feedback Anti-Islanding Method Based on a Robust PLL Algorithm for Grid-Connected PV PCS

  • Lee, Jong-Pil (Power Conversion & System for Renewable Energy Center, KERI) ;
  • Min, Byung-Duk (Green Power Co., Ltd.) ;
  • Kim, Tae-Jin (Power Conversion & System for Renewable Energy Center, KERI) ;
  • Yoo, Dong-Wook (Power Conversion & System for Renewable Energy Center, KERI) ;
  • Yoo, Ji-Yoon (Dept. of Electrical Engineering, Korea University)
  • Received : 2010.09.09
  • Published : 2011.05.20

Abstract

This paper proposes an active frequency with a positive feedback in the d-q frame anti-islanding method suitable for a robust phase-locked loop (PLL) algorithm using the FFT concept. In general, PLL algorithms for grid-connected PV PCS use d-q transformation and controllers to make zero an imaginary part of the transformed voltage vector. In a real grid system, the grid voltage is not ideal. It may be unbalanced, noisy and have many harmonics. For these reasons, the d-q transformed components do not have a pure DC component. The controller tuning of a PLL algorithm is difficult. The proposed PLL algorithm using the FFT concept can use the strong noise cancelation characteristics of a FFT algorithm without a PI controller. Therefore, the proposed PLL algorithm has no gain-tuning of a PI controller, and it is hardly influenced by voltage drops, phase step changes and harmonics. Islanding prediction is a necessary feature of inverter-based photovoltaic (PV) systems in order to meet the stringent standard requirements for interconnection with an electrical grid. Both passive and active anti-islanding methods exist. Typically, active methods modify a given parameter, which also affects the shape and quality of the grid injected current. In this paper, the active anti-islanding algorithm for a grid-connected PV PCS uses positive feedback control in the d-q frame. The proposed PLL and anti-islanding algorithm are implemented for a 250kW PV PCS. This system has four DC/DC converters each with a 25kW power rating. This is only one-third of the total system power. The experimental results show that the proposed PLL, anti-islanding method and topology demonstrate good performance in a 250kW PV PCS.

Keywords

References

  1. R. C. Dugan and T. E. McDermott, "Distributed generation," Industry Applications Magazine, IEEE, Vol. 8, Issue 2, pp. 19-25, Mar./Apr. 2002. https://doi.org/10.1109/2943.985677
  2. V. Kaura and V. Blasko "Operation of a phase locked loop system under distorted utility conditions," IEEE Trans. Ind. Appl., Vol. 33, No. 1, pp. 58-63, Jan./Feb. 1997. https://doi.org/10.1109/28.567077
  3. P. Rodriguez, L. Sainz, and J. Bergas "Synchronous double reference frame PLL applied to a unified power quality conditioner," Harmonics and Quality of Power, 2002, 10th International Conference on Volume 2, pp. 614-619, 2002.
  4. P. Rodriguez, J. Pou, J. Bergas, I. Candela, R. Burgos, and D. Boroyevic "Double synchronous reference frame PLL for power converters control," PESC'05, pp. 1415-1421, Sep. 2005.
  5. R. I. Bojoi, G. Griva, V. Bostan, M. Guerriero, F. Farina and F. Profumo "current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame," IEEE Trans. Power Electron., Vol. 20, No. 6, pp. 1402-1412, Nov. 2005.
  6. P. Rodriguez, R. Teodorescu, I. Candela, A. V. Timbus, M. Liserre, and F. Blaabjerg, "New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions," PESC'06, 18-22, pp. 1-7, Jun. 2006.
  7. J. P. Lee, B. D. Min, T. J. Kim, D. W. Yoo, and J. Y. Yoo, "A novel topology for photovoltaic DC/DC full bridge converter with flat efficiency under wide PV module voltage and load range," IEEE Trans. Ind. Electron., Vol. 55, Issue 7, pp. 2655-2663, Jul. 2008. https://doi.org/10.1109/TIE.2008.924165
  8. J. T. Bialasiewicz, "Renewable energy systems with photovoltaic power generators: operation and modeling," IEEE Trans. Ind. Electron., Vol. 55. No. 7, pp. 2752-2758, Jul. 2008. https://doi.org/10.1109/TIE.2008.920583
  9. R. M. Santos Filho, P. F. Seixas, P. C. Cortizo, L. A. B. Torres, and A. F. Souza, "comparison of three single-phase PLL Algorithms for UPS applications," IEEE Trans. Ind. Electron., Vol. 55. Issue 8, pp. 2923-2932, Aug. 2008. https://doi.org/10.1109/TIE.2008.924205
  10. J. M. Carrasco, L. G. Franquelo, I. T. Bialasiewicz, E. Galvan, R. C. PortilloGuisado, M. A .M. Prats, J. I. Leon, and N. Moreno-Alfonso, "Power-electronic systems for the grid integration of renewable energy sources: a survey," IEEE Trans. Ind. Electron., Vol. 53, No. 4, pp. 1002-1016, Jun. 2006. https://doi.org/10.1109/TIE.2006.878356
  11. J.-P. Lee, B.-D. Min, T.-J. Kim, D.-W. Yoo, and J.-Y. Yoo "Design and control of novel topology for photovoltaic DC/DC converter with high efficiency under wide load ranges," Journal of Power Electronics, Vol. 9, No. 4, pp. 300-307, Jul. 2009.
  12. R. Leyva, C. Alonso, I. Queinnec, A. Cid-Pastor, D. Lagrange, and L. Martinez-Salamero, "MPPT of photovoltaic systems using extremumseeking control," IEEE Trans. Aerosp. Electron. Syst., Vol. 42, No. 1, pp. 249-258, Jan. 2006. https://doi.org/10.1109/TAES.2006.1603420
  13. B.-D. Min, J.-P. Lee, J.-H. Kim, T.-J. Kim, and D.-W. Yoo, "A new topology with high efficiency throughout all load range for photovoltaic PCS," IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4427-4435, Nov. 2009. https://doi.org/10.1109/TIE.2008.928098
  14. Quan Li, Wolfs. P, "A Review of the Single Phase Photovoltaic Module Integrated Converter Topologies with Three Different DC Link Configurations," IEEE Trans. on Power Electronics, Vol. 23, No. 3, pp. 1320-1333, May. 2008. https://doi.org/10.1109/TPEL.2008.920883
  15. M. G. Villava, J. R. Gazoli, and E. R. Filho, "Comprehensive approach to modeling and simulation of photovoltaic arrays," IEEE Trans. Power Electron., Vol. 24, No. 5, pp. 1198-1208, May 2009.
  16. T. Kerekes, M. Liserre, R. Teodorescu, C. Klumpner, and M. Sumner, "Evaluation of three-phase transformerless photovoltaic inverter topology," IEEE Trans. Power Electron., Vol. 24, No. 9, pp. 2202-2211, Sep. 2009. https://doi.org/10.1109/TPEL.2009.2020800
  17. Sirukarumbur Panduranfgan Natarajan, and Thangavel Saroja Anandhi, "Control of input series output parallel connected DC-DC converters," Journal of Power Electronics, Vol. 7, No. 3, pp. 265-270, Jul. 2007.
  18. K.-S. Lee, K. Yamaguchi, and K. Kurokawa, "Proposed distribution voltage control method for connected cluster PV systems," Journal of Power Electronics, Vol. 7, No. 4, pp. 286-293, Oct 2007.
  19. X. Weidong, N. Ozog, and W. G. Dunford, "Topology study of photovoltaic interface for maximum power point tracking," IEEE Trans. Ind. Electron., Vol. 54, No. 3, pp. 1696-1704, Jun. 2007.
  20. J.-P. Lee, B.-D. Min, J.-H. Kim, T.-J. Kim, D.-W. Yoo and J.-Y. Yoo, "Input-series-output-parallel connected DC/DC converter for photovoltaic PCS with high efficiency under a wide load range," Journal of Power Electronics, Vol. 10, No. 1, pp. 9-13, Jan. 2010. https://doi.org/10.6113/JPE.2010.10.1.009
  21. W. Bower and M. Ropp, "Evaluation of Islanding Detection Methods For Photovoltaic utility," International Energy Agency, Report IEA PVPS T5-09: 2002.
  22. H. Kobayashi, K. Takigawa, and E. Hashimoto, "Method for preventing islanding phenomenon on utility grid with a number of small scale PV systems," Record of. IEEE Photovoltaic Specialists Conference, pp. 695-700, 1991.
  23. M. E. Ropp, M. Begovic, and A. Rohatgi, "Prevention of islanding in grid-connected photovoltaic systems," Progress in Photovoltaics: Research and Applications, Vol. 7, pp. 39-59, 1999.

Cited by

  1. Power system frequency estimation using a least mean squares differentiator vol.87, 2017, https://doi.org/10.1016/j.ijepes.2016.11.001
  2. Proposed Sandia frequency shift for anti-islanding detection method based on artificial immune system 2017, https://doi.org/10.1016/j.aej.2016.12.020
  3. Implementation of a High Efficiency Grid-Tied Multi-Level Photovoltaic Power Conditioning System Using Phase Shifted H-Bridge Modules vol.13, pp.2, 2013, https://doi.org/10.6113/JPE.2013.13.2.296
  4. A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization Applications vol.16, pp.2, 2016, https://doi.org/10.6113/JPE.2016.16.2.717
  5. Sensorless Control Method for PMSM Based on Frequency-Adaptive Disturbance Observer vol.2, pp.2, 2014, https://doi.org/10.1109/JESTPE.2013.2296596
  6. A Novel Grid Synchronization PLL Method Based on Adaptive Low-Pass Notch Filter for Grid-Connected PCS vol.61, pp.1, 2014, https://doi.org/10.1109/TIE.2013.2245622
  7. A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids vol.16, pp.4, 2016, https://doi.org/10.6113/JPE.2016.16.4.1513
  8. AC Regeneratable Battery Charging and Discharging Test System vol.17, pp.2, 2012, https://doi.org/10.6113/TKPE.2012.17.2.99
  9. High-Efficiency Isolated Bidirectional AC–DC Converter for a DC Distribution System vol.28, pp.4, 2013, https://doi.org/10.1109/TPEL.2012.2213347
  10. Implementation of Fault Ride-Through Techniques of Grid-Connected Inverter for Distributed Energy Resources With Adaptive Low-Pass Notch PLL vol.30, pp.5, 2015, https://doi.org/10.1109/TPEL.2014.2378792
  11. Implementation of a Smart Power Conditioning System for Energy Storage System with a Novel Seamless Transfer Strategy vol.11, pp.5, 2018, https://doi.org/10.3390/en11051108