Design of Structure of Heliostat Reflective Surface for 200kW Tower Type Solar Thermal Power Plant

200kW 탑형 태양열발전시스템을 위한 Heliostat 반사면 구조 설계

  • Park, Young-Chil (Department of Control and Instrumentation Engineering Seoul National University of Science and Technology)
  • 박영칠 (서울과학기술대학교 제어계측공학과)
  • Received : 2011.01.23
  • Accepted : 2011.03.28
  • Published : 2011.04.30

Abstract

Heliostat in the tower type solar thermal power plant is a sun tracking mirror system to reflect the solar energy to the receiver and the optical performance of it affects to the efficiency of whole power plant most significantly. Thus a proper design of structure of the heliostat reflective surface could be the most important step in the construction of such power plant. The work presented here is a design of structure of optical surface of heliostat, which will be used in 200kW solar thermal power plant. The receiver located at 43(m) high from ground in tower has $2{\times}2$(m) rectangular shape. We first developed the software tool to simulate the energy concentration characteristics of heliostat using the ray tracing technique. Then, the shape of heliostat reflective surface is designed with the consideration of heliostat's energy concentration characteristics, production cost and productivity. The designed heliostat's reflective surface has a structure formed by canting four of $1{\times}1$(m) rectangular flat plate mirror facet and the center of each mirror facet is located on the spherical surface, where the spherical surface is formulated by the mirror facet mounting frame.

Keywords

References

  1. PIER: California Energy Commission, "Renewable Energy : Solar two centralreceiver", October 1999
  2. http://en.wikipedia.org/wiki/PS10_Solar_Power_Plan
  3. Y.T. Chen, B.H. Lim and C.S. Lim, "Off-axis aberration correction surface in solar energy application", Solar Energy, Vol.80, 2006, pp. 268-271 https://doi.org/10.1016/j.solener.2005.02.011
  4. R. Zaibel, E. Dagan, J. Karniand H. Ries, "An astigmatic corrected target aligned heliostat for high concentration", Solar Energy Materials and Solar Cells,Vol. 37, 1995, pp. 191-202 https://doi.org/10.1016/0927-0248(94)00206-1
  5. F.J. Collard, A.Gomez and J.A. Turegano. "Ananalytic function for the fluxd ensity due to sunlight reflected from a heliostat", Solar Energy, Vol.37, 1986, pp. 215-234 https://doi.org/10.1016/0038-092X(86)90078-2
  6. F.W. Lipps and M.D. Walzel," Ananalytic evaluation of the flux density due to sunlight reflected from a flat mirror having a polygonal boundary", Solar Energy, Vol. 21, 1978, pp. 113-121 https://doi.org/10.1016/0038-092X(78)90038-5
  7. J.C. Henne and J.L. Abatut,"Ananalytical method for reflected flux density calculations", Solar Energy, Vol. 32, 1984, pp. 357-363 https://doi.org/10.1016/0038-092X(84)90279-2
  8. P. Garcia, A. Ferriere and J. Bezian, "Codes for solar flux calculation dedicated to central receiver system applications: A comparative review", Solar Energy, Vol. 82, 2008, pp. 189-197 https://doi.org/10.1016/j.solener.2007.08.004
  9. Wei Xiudong, "Study on the heliostat field design in the solar tower power plant", Ph. D Dissertation, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Science, China, May 2009
  10. 박영칠, "Heliostat 제어시스템", 한국태양에너지학회논문집, Vol. 29, No.1, 2009, pp. 50-57
  11. E.A. Igeland R.L. Hughes, "Optical analysis of solar facility heliostats", Solar Energy, Vol. 22, 1979, pp. 283-295 https://doi.org/10.1016/0038-092X(79)90143-9