DOI QR코드

DOI QR Code

The comparative study on the marginal fit of a metal-ceramic alloy, IPS - Empress and a zirconia($ZrO_2$) ceramic used for fabrication of dental restoration

치과보철물 제작에 사용되는 금속-도재용 합금, IPS - Empress, 지르코니아($ZrO_2$) 세라믹의 변연적합도에 관한 비교평가

  • Received : 2011.02.01
  • Accepted : 2011.03.21
  • Published : 2011.03.30

Abstract

Purpose: As the demand and importance of aesthetic aspects in dental treatment become higher, much attention is paid to materials used for dental prostheses. Thus, the marginal fidelity of most-commonly used alloy, IPS - Empress and ZrO2 ceramic is compared. Methods: The alloy core made by casting, IPS - Empress core made by pressing and ZrO2 ceramic core made by CAD/CAM are used to make 10 samples respectively. For each core, three points were measures and the optical microscope (Axio Imager.Alm,Zeiss co., Oberkochen, Germany) was used to observe the cores with a magnification of 100. Results: As for alloy, IPS - Empress and ZrO2 ceramic, the average and deviation of their marginal distance are $29.91\;{\pm}11.93{\mu}m$ for alloy, $33.45\;{\pm}8.61{\mu}m$ for IPS - Empress, and $31.55\;{\pm}9.85{\mu}m$ for ZrO2. The one-way ANOVA test was conducted to compare them. However, there was no statistically significant difference among them. Conclusion: The study on marginal fidelity of alloy, IPS - Empress, and ZrO2 ceramic shows they have no marginal fidelity problem clinically. Therefore, if a system is selected based on the patient's condition or treatment method, there will be no problem.

Keywords

References

  1. 관교의치기공학교육연구회. 관교의치기공학. 개정판, 대학서림, 46, 2002.
  2. 고영학, 정종현. 치과용 세라믹 소재 개발동향. 제44차 (자)대한치과기재협의회 종합학술대 및 치기공 기자재 전시회지, 37, 2008.
  3. 배지명, 김경남. 치과용 비귀금속 합금의 열처리에 따른 미세조직 및 기계적 성질의 변화. 대한치과기재학회지, 29, 4, 2002.
  4. 이인규, 최운재. 치과보철물 제작에 사용되는 Nickel-Chromium계 합금의 치경부 변연에 관한 적합성. 대한치과기공학회지, 13, 1, 1991.
  5. 허중보, 박청길, 김하영, 박찬경, 신상완 수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가. 대한치과보철학회지, 48권, 2호, 135, 25-29, 2010.
  6. Andersson M, Razzoog ME, Ode'n A, Hegenbarth EA, Lang BR. Procera: a new way to achieve an all-ceramic crown. Quintessence Int, 29, 285-96, 1998
  7. Anusavice KJ, Okabe T, Galloway SE. Flexure test evaluation of presoldered base metal alloys. J Prosthet Dent, 54, 507-517, 1985. https://doi.org/10.1016/0022-3913(85)90423-8
  8. Anusavice KJ, Shafagh I. Inert gas presoldering of nickel-chromium alloys. J Pros Dent, 55, 317-323, 1986. https://doi.org/10.1016/0022-3913(86)90111-3
  9. Baran GR. The metallurgy of Ni-Cr alloys for fixedprosthodontics. J Pros Dent, 50, 639, 1983. https://doi.org/10.1016/0022-3913(83)90201-9
  10. Boening KW, Wolf BH, Schmidt AE, K¨astver K, Walter MH. Clinical fit of Procera Allceram crowns. J Prosthet Dent, 84, 419-24, 2000. https://doi.org/10.1067/mpr.2000.109125
  11. Gassino G, Barone Monfrin S, Scanu M, Spina G, Preti G.Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure. Int J Prosthodont, 17, 218-23, 2004.
  12. Groten M, Axmann D, Pro ¨bster L, Weber H. Determination of the minimum number of marginal gap measurements required for practicalin-vitro testing. J Prosthet Dent, 83, 40-9, 2000. https://doi.org/10.1016/S0022-3913(00)70087-4
  13. Fradeani M Aquilano A. Clinical experience with Empress crowns. Int J Prosthodont, 10(3), 241-7, 1997.
  14. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent, 62, 405-8, 1989. https://doi.org/10.1016/0022-3913(89)90170-4
  15. Moon BH, Yang JH, Lee SH, Chung HY. A study on the marginal fit of all-ceramic crown using ccd camera. J Korean Acad Prosthodont, 36, 273-92, 1998.
  16. Preston JD, Berger R. Laboratory variables affectingceramometal alloys. Dent Clin North Am, 21, 717, 1977.
  17. Rosenblum MA, Schulman A.A review of allceramic restorations. J Am Dent Assoc, 128 (7), 818, 1997.
  18. Seghi PR, Sorensen JA. Relative flexural strength of six new ceramic materials. Int J Prosthodont, 8, 239-46, 1995.
  19. Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent, 64, 18-24, 1990. https://doi.org/10.1016/0022-3913(90)90147-5
  20. Sturdevant JR, Bayne SC, Heymann HO. Margin gap size of ceramic inlays using secondgeneration CAD/CAM equipment. J Esthet Dent, 11, 206-14, 1999. https://doi.org/10.1111/j.1708-8240.1999.tb00400.x
  21. Weiss PA. New design parameters: Utilizing theproperties of Ni-Cr super alloys. Dent Clin North Am, 21, 749, 1977.

Cited by

  1. 베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구 vol.34, pp.4, 2011, https://doi.org/10.14347/kadt.2012.34.4.337