DOI QR코드

DOI QR Code

Effects of the Geometry of Components Attached to the Drain Valve on the Performance of Water Hammer Pumps

  • Saito, Sumio (Department of Mechanical Engineering, Tokyo National College of Technology) ;
  • Takahashi, Masaaki (Mechanical and Computer Systems Engineering, Advanced Engineering Course, Tokyo National College of Technology) ;
  • Nagata, Yoshimi (Yamaha Motor Engineering Co., Ltd.) ;
  • Dejima, Keita (Department of Mechanical Engineering, Tokyo National College of Technology)
  • 투고 : 2011.04.11
  • 심사 : 2011.09.30
  • 발행 : 2011.12.31

초록

Water hammer pumps can effectively use the water hammer phenomenon in long-distance pipeline networks that include pumps and allow fluid transport without drive sources, such as electric motors. The results of experiments that examined the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. In addition, a paper has also been published analyzing the water hammer phenomenon numerically by using the characteristic curve method for comparison with experimental results. However, these conventional studies have not fully evaluated the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. Therefore, as a first stage for the understanding of water hammer pump performance in comparison with the characteristics of typical turbo pumps, the previous paper experimentally examined how the hydrodynamic characteristics were affected by the inner diameter ratio of the drive and lifting pipes, the form of the air chamber, and the angle of the drive pipe. To understand the behavior of the components attached to the valve chamber and the air chamber that affects the performance of water hammer pumps, the previous study also determined the relationship between the water hammer pump performance and temporal changes in valve chamber and air chamber pressures according to the air chamber capacity. For the geometry of components attached to the drain valve, which is another major component of water hammer pumps, this study experimentally examines how the water hammer pump performance is affected by the length of the spring and the angle of the drain pipe.

키워드

참고문헌

  1. Kagami, K., Ide, T., and Ushiyama, I., 2001, "Water hammer pump production handboo," (in Japanese), POWERSHA Inc., pp. 47.
  2. Yunoki, T., 2004, "Production of a Hydraulic Ram Pump and its Research on its Characteristic," Japan Society for Science Education, (in Japanese), Vol. 28, No .2, pp. 94-100.
  3. Tessema, A. A., 2000, "Hydraulic Ram Pump System Design and Application," Proceedings of ESME 5th Annual Conference on Manufacturing and Process Industry, September 2000, pp. 1-8.
  4. Hasegawa, S., Suehiro, H., and Yamaguchi, K., 1984, "Trial of Hydraulic Ram and Its Performance Characteristics," Research Reports of Toyota College of Technology, (in Japanese), No. 17, pp. 15-20.
  5. Taye, T., 1998, "Hydraulic Ram Pump," Journal of the ESME, Vol. II, No. 1 (1998-7), pp. 1-11.
  6. Okada, U., Uetsuki, H., and Takenaka, T., 1982, "Research on Water Hammer Pump (1st Rep. Mathematical Model on Water Hammer Pump), Turbomachinery, (in Japanese), Vol. 10, No. 6 (1982-6), pp. 323-334.
  7. Saito, S., Nagata, Y., Takahashi, M., Inoue, D., and Hoshino, Y., "Relationship between the Basic Geometric Form and Hydraulic Characteristics of Water Hammer Pump," Transactions of the Japan Society of Mechanical Engineers, Series B, No. 09-1092, (in Japanese), Vol. 76, No. 767 (2010-7), pp. 1028-1034. https://doi.org/10.1299/kikaib.76.767_1028
  8. Saito, S., Takahashi, M., and Nagata, Y., "Effects of the Air Volume in the Air Chamber on the Performance of Water Hammer Pump System," Turbomachinery, (in Japanese), Vol. 39, No. 2 (2011-2), pp.87-94.