치과 임플란트 수술 보조 로봇(ARDIS) 시술 방법

  • 김광호 ((재)광주테크노파크 가전로봇센터) ;
  • 조연술 ((재)광주테크노파크 가전로봇센터) ;
  • 강동완 (조선대학교 치의학과) ;
  • 정상화 (조선대학교 기계공학과)
  • 발행 : 2011.02.15

초록

키워드

참고문헌

  1. Brief, J., Hassfeld. S., Redlich. T. and Ziegler, C" 2000, "Robot assisted insertion of dental implants-a cillical evaluation," Int, J, of Computer Assisted Radiology and Surgery-CARS, pp, 932-937.
  2. Brief, J., Hassfeld, S., Boesecke, R., Vogele, M., Krempien, R., Treiber, M. and Miihling, J., 2002, "Robot assisted Dental Implantology," Int, Poster J., Vol, 4, No, 1, Poster, 109,
  3. Albrektsson, T., Zarb, G., Wortrlington, P, and eriksson, A, R., 1986, "The long term eliiciency of currently used dental A review and proposed criteria of success," Int, J, Oral Maxillofac. Implants, Vol, 1, No, 1, pp, 11-25,
  4. Ekfeldf. A, Carlsson, G, E. and B rjesson. G., 1994, "Clinical evaluation of the single-tooth restorations supported by osseontegrated implant: A retrospective study," Int, J, Oral Maxillofac, Implants, Vol, 9, No, 2, pp, 179-183.
  5. English, C. E., 1993, "Implant-supported versus implantnatural- tooth-supported fixed partial dentures," J, Dent. Symp., Vol. 1, pp, 10-15.
  6. Jemt, T., 1991, "Osseo[ntegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study," Int. J. Oral Maxillofac. Implants., Vol. 6, pp, 29-42.
  7. Jemt. T., Linden. B, and lekhlm. U., 1990, "Failures and comoplication in 127 consecutively placed fixed partial prostheses suppoted by Branemark implants: From prosthetic treatment to first annual checkup," Int, J. Oral Maxiliofac. Implants., Vol. 7, pp. 185-194,
  8. Misch, C. E., 1993, Contemporary implant dentistry, Mosby-Year Book, Inc. St. Louis.
  9. Naert, I., Quirynen, M., Steenberghe, D., Darius, P., 1992, "Six-year prosthodontic study of 509 consecutive inserted implants for the treatment of partial edentulism," J. Prosthet. Dent., Vol. 67, pp. 236-245. https://doi.org/10.1016/0022-3913(92)90461-I
  10. Schicho, K., Kronrief, G. and Ewers, R., 2007, "Theoretical background for the development of a robot in navigated dental implantology," Int. J. CARS., Vol, 2, pp. S412-S418. https://doi.org/10.1007/s11548-007-0110-8
  11. J rg, N., 2004, "Fabrication of Surgical Template for CT-based Implant Planning," International Poster of Journal Dental Oral Medical, Vol. 6, No. 04, Poster. 248.
  12. Tactile Technologies Ltd., Implant loacation system, Israel, (http://www.tactile-tech.com)
  13. Ewers, R., Schicho, K., Reichwein, A. and Shohat, M., 2007, "Navigated template based implantology-the innovative ImplantKissTM workflow," Proc. of 4th Int. Conf. on computer Aided Surgery around the Head.
  14. Nobel Biocarem, NobleGuide, Switzerland, (http://www.nobelbiocare.com)
  15. Materialise Ental NV., Simplant, (http://www.materialise.com)
  16. Ewers, R., Schicho, K., Seemann, R., Reichwein, A., Figl, M. and Wagner, A., 2004, "Computer aided navigation in dental implaniology: 7 years of clinical experience," J. Oral Maxillofac. Surg., Vol. 62, No. 3, pp, 329-334. https://doi.org/10.1016/j.joms.2003.08.017
  17. Kruger T., 2006, "Ein modulares Navigationssystem fur die dentale Implantologle." PhD-Thesis, Technical University of Berlin.
  18. Brief, J., Hassfeld, S., Sonnenleld, U., Persky, N., Krempien, R., Treiber, M., and Muhling, J., 2001, "Computer guided insertion of dental Implants-a clinical evaluation," CARS2001, pp. 696-701.
  19. Shapira, L., 2002, "Image guided implantology-real-time guidance of dental implant surgery in the operative field using CT-scan image," CARS2002, pp. 959-964.
  20. Schermeier, O., Lueth, T., Cho, C., Hildebrand, D., Klein, M, Nelson, K. and Bier, J., 2002, "The precision of the RoboDent System-An in vitro study," CARS2002, pp. 947-952.
  21. Watzinger, F., Birkfellner, W., Wanschitz, F., Millesi, W., Schopper, C., Sinko, K., Huber, K., Bergmann, H. and Ewers, R., 1999, "Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method," J. of Cranio-Maxillofacial Surg., Vol. 27, No. 2, pp.77-81. https://doi.org/10.1016/S1010-5182(99)80017-1
  22. Zoppi, M., Zlatanov, D. and Gosselin, C. M., 2005, "Analytical kinematics models and special geometries of a class of 4-DOF parallel mechanisms," IEEE Trans. on Robotics, Vol. 21, No. 6, pp. 1-10. https://doi.org/10.1109/TRO.2004.838000
  23. Szymanski, D., Hein, A. and Lueth, T. C., 2003, "Navi-X-a planning and treatment system for dental implantology based on navigated projection images," International Congress Series. No. 1256, pp. 1243-1249.
  24. Kramer, F. J., Baethge, C., Swennen, G. and Rosahl, 2004, "Navigated vs. conventional implant insertion for maxillary single tooth replacement," Clinical Oral Implant Research, Vol. 16, No. 1, pp. 60-68. https://doi.org/10.1111/j.1600-0501.2004.01058.x
  25. Kim, E. K., 1996, "Image reformation with apersonal computer for dental implant planning," Korea Journal of Oral Medicine, Vol. 21, No. 2, pp. 255-264.
  26. Marmulla, R., Brief, J., Heurich, T., Muhling, J. and Hassfeld, S., 2002, "Perspectives of computer aided implantology, Z Zahn rztl Implantol, Vol. 18, pp. 152-158.
  27. Medtronic Navigation Co., StealthStation Catalog, Louisville, USA (http://www.medtronicnavigation.com)
  28. Korb W., Kornfeld M., Birkfellner W, Boesecke R., Figl M., Fuerst M., Kettenbach J., Vogler A., Hassfeld S. and Kronreif G., 2005, Risk analysis and safety assessment in surgical robotics: a case study on a biopsy robot. Minim. Invasive Ther. Allied Technol, Vol. 14, No. 1, pp. 23-31. https://doi.org/10.1080/13645700510010827
  29. Koulechov, K. and Lueth, T., 2004, "A new metric for drill location for Navigated Control in navigated dental implantology," International congress Series, Vol. 1268, pp. 1220-1225.
  30. Brisman, D., 1996, "The effect of speed, pressure, and time on bone temperature during the drilling of implant sites," Int. J. Oral Maxillofac Implants, Vol. 11, pp. 35-37.
  31. Iyer, S., Weiss, C., and Mehta, A., 1997, "Effects of drill speed on heat production and the rate and quality of bone formation in dental osteotomies. Part II: relationship between drill speed and healing," Int. J. Prosthodont, Vol. 10, No. 6, pp. 536-540.
  32. Sharawy, M. and Misch, C., 2002, "Heat generation during implant drilling: The significance of motor speed," J. Oral Maxillofac Surg., Vol. 60, pp. 1160-1169. https://doi.org/10.1053/joms.2002.34992