Abstract

This research examines problem that can happen in partial smoke control method among contiguity area smoke control system through engineering examination and CFD. And the ultimate purpose of this is to secure safety of a person inhabiting at fire department by presenting improvement plan. Now a days, in large space-area such as department store or mega-mall in which mainly applies "Partial Smoke Control Method", air is suppled from adjacent area and smoke is exhausted in fire room. For various reason, however, it is confirmed through simulation that if air is suppled in one direction, this can cause a fatal result to people of fire area because of the difficulty in securing the evacuation time. As an improvement plan, air is supplied at the same time in surroundings to fire department.

본 연구에서는 제연방식 중 대형공간에서 주로 사용하는 거실급배기 방식에서 급기방식 및 방향에 따른 연기의 이동현상에 대해 CFD 도구인 FDS(Fire Dynamics Simulator) 프로그램을 이용하여 확인해 보았다. 거실급배기 방식에서는 Sequence 설계의 어려움으로 주로 한쪽 방향에서만 급기가 이루어지는데, 한 방향에서만 급기를 실시할 경우 연기의 팽창압력에 급기되는 공기의 압력이 가중되어 원하지 않는 인접구역으로의 연기확산 속도가 빨라진다. 연기가 인접구역으로 확산되는 것을 최소화 하고 재실자의 피난시간을 최대한 보장하기 위해 급기를 한 방향이 아닌 화재실 인접구역에서 나누어 시행해 보았으며, 결론적으로 화재실 주변의 가시거리 감소시간은 인접구역이 비슷한 수준으로 조정되는 것을 확인할 수 있었다.

Keywords

References

  1. Society of Fire Protection Engineers, "The SFPE handbook of Fire Protection Engineering", 3rd Ed, the National Fire Protection Association, Massachusetts (2002).
  2. CCDE, "Mechanical Exhaust Ventilation Systems; Design, Calculations, and Operational Guidelines", California Conference of Directors of Environmental Health(2000).
  3. H.P. Morgan, "Design Principles for Smoke Ventilation in Enclosed Shopping Centres", Building Research Establishment Report(1991).
  4. NFPA, "NFPA 92A Standard for Smoke-Control System Utilizing Barriers and Pressure Differences" (2009).
  5. BS5588-12, "Fire Precautions in the Design, Construction and Use of Buildings - Part 12: Managing Fire Safety"(2004).
  6. Abhishek Jain, Ajay Mishra, "CFD Analysis for smoke Ventilation in High Rises", Zeus Numerix Private Limited(2010).
  7. H.P. Morgan, "Design Methodologies for Smoke and Heat Exhaust Ventilation", Construction Information Service(1999).
  8. John R. Hall, "An Analysis of Automatic Sprinkler System Reliability Using Current Data", National Fire Protection Association(2006).
  9. 구진영, 김광일, "백화점 화재 발생의 확률적 접근에 의한 심각성의 정량적 예측", 한국화재소방학회지(29 호), Vol.12, No.1(1998).
  10. 김태욱, "자동 스프링클러 시스템의 신뢰성에 대한 조사연구", 석사학위논문(2006).
  11. 남상욱, "소방시설의 설계 및 시공", 성안당, 2008.
  12. 박헌식, "물류센터의 소방시설과 방재대책", 방재와 보험 96(2003).
  13. 이수경 외, "시뮬레이션을 통한 화재피난 평가 Case Study 과정", 도서출판 아진(2010).
  14. 이창욱, "신방화공학", 도서출판 의제(2000).
  15. 소방방재청, "2009 국가화재안전기준(NFSC) 해설서", 소방방재청(2009).
  16. 백열선, 寗拈黎璲雍낳竹, 형설출판사(2003).
  17. 민세홍, 윤정은, "FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구", 대한안전경영과학회지, Vol.11, No.2(2009).