DOI QR코드

DOI QR Code

Application of High-Performance Steels to Enhance the Punching Shear Capacity of Two-Way Slabs

2방향 슬래브의 펀칭전단성능 향상을 위한 고성능 철근의 적용

  • 양준모 (고려대학교 건축사회환경공학부) ;
  • 신현오 (고려대학교 건축사회환경공학부) ;
  • 이주하 (삼성물산(주) 건설부문 기술연구소) ;
  • 윤영수 (고려대학교 건축사회환경공학부)
  • Received : 2010.11.16
  • Accepted : 2011.01.03
  • Published : 2011.03.30

Abstract

Two-way slabs reinforced with high-performance steels, which have several practical advantages of a reduction of congestion in heavily reinforced members, savings in the cost of labor and repair, the higher corrosion resistance, and a reduction of construction time, were constructed and tested. The influences of the flexural reinforcement ratio, concentrating the reinforcement in the immediate column region, and using steel fiber-reinforced concrete (SFRC) in the slab on the punching shear resistance and post-cracking stiffness were investigated, and compared with the punching shear test results of the slabs reinforced with conventional steels and GFRP bars. In addition, the strain distribution of flexural reinforcements and crack control were investigated, and the effective width calculating method for the average flexural reinforcement ratio was estimated. The use of high-performance steel reinforcement increased the punching shear strength of slabs, and decreased the amount of flexural reinforcements. The concentrating the top mat of flexural reinforcement increased the post-cracking stiffness, and showed better strain distribution and crack control. In addition, the use of SFRC showed beneficial effects on the punching shear strength and crack control. It was suggest that the effective width should be changed to larger than 2 times the slab thickness from the column faces.

본 연구에서는, 철근 밀집 감소, 노무비 및 보수 보강비 절약, 향상된 부식 저항성, 공기 단축 등의 장점을 가지고 있는 고성능 철근으로 휨 보강된 이방향 슬래브를 제작하고 구조실험을 실시하였다. 상부 휨철근비, 기둥 인접부 휨철근의 집중배근, 강섬유 보강 콘크리트의 타설을 변수로 하여 실험하였고, 펀칭 전단강도 및 균열후 강성을 일반 철근 및 GFRP bar로 휨 보강된 슬래브의 펀칭 전단실험 결과와 비교하였다. 또한, 휨철근의 변형률 분포 및 균열제어 효과 등을 비교, 분석하였고, 휨철근비 계산을 위한 유효폭 산정 방법을 검토하였다. 고성능 철근의 사용으로 펀칭 전단강도가 향상되었고, 휨 철근량을 감소시킬 수 있었다. 기둥 인접부 휨철근의 집중배근을 통해 철근비의 감소 때문에 작아진 강성을 회복시킬 수 있었고, 훌륭한 변형률 분포 및 균열제어 효과를 나타내었다. 또한, 기둥 인접부에 대한 강섬유 보강 콘크리트의 타설은 펀칭 전단강도의 증가와 균열 제어에 탁월한 효과를 보였다. 휨철근비 산정을 위한 유효폭은 기둥면으로부터 슬래브 두께의 2배 이상으로 확대하는 것이 합리적이라 판단된다.

Keywords

References

  1. 이주하, 양준모, 윤영수, "2방향 슬래브의 성능 향상을 위한 집중 배근된 FRP 바의 적용", 한국콘크리트학회 논문집, Vol.19, No. 6, 2007, pp.727-734.
  2. 한국콘크리트학회, 콘크리트 구조설계기준 해설, 한국콘크리트학회, 2007, p.523.
  3. ACI Committee 408, Bond and Development of Straight Reinforcing Bars in Tension, ACI 408R-03, American Concrete Institute, Farmington Hills, Mich., 2003, 49pp.
  4. Alexander, S. B. D. and Simmonds, S. H., "Test of Column-Flat Plate Connections", ACI Structural Journal, Vol. 89, No. 5, 1992, pp.495-577.
  5. American Concrete Institute(ACI), Building Code Requirements for Structural Concrete and Commentary, ACI 318-08 and ACI 318M-08, Farmington Hill, MI, 2008, p.473.
  6. American Concrete Institute(ACI), Guide for the Design and Construction of Structural Concrete Reinforced with FRP Bars, ACI 440.1R-06, Farmington Hill, MI, 2006, p.44.
  7. ASTM International, Standard Specification for Deformed and Plain, Low-Carbon, Chromium, Steel Bars for Concrete Reinforcement, ASTM A1035-07, West Conshohocken, PA, 2007, p.47.
  8. ASTM International, Standard Test Methods and Definitions for Mechanical Testing of Steel Products, ASTM A370-08, West Conshohocken, PA, 2008, 47pp.
  9. British Standard Institution(BSI), Structural Use of Concrete, Standard BS 8110, London, United Kingdom, 1997, p.168.
  10. Canadian Standards Association(CSA), Design of Concrete Structures, CSA A23.3-04, Mississauga, ON, Canada, 2004, p.249.
  11. Dilger, W., Birkle, G., Mitchell, D., "Effect of Flexural Reinforcement on Punching Shear Resistance", Punching Shear in Reinforced Concrete Slabs, SP-232, M. A. Polak, ed., American Concrete Institute, Farmington Hills, MI, 2005, pp.57-73.
  12. European Standard, Eurocode 2: Design of Concrete Structures-Part 1: General Rules and Rules for Buildings, prEN 1992-1-1, Final Draft, European Committee for Standardization, Brussels, 2003, p.226.
  13. Ghannoum, C. M., Effect of High-Strength Concrete on the Performance of Slab-Column Specimens, M. Engrg. Thesis, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal, QC, Canada, 1998, p.91.
  14. Hassan, T. K., Seliem, H. M., Dwairi, H., Rizkalla, S. H. and Zia, P., "Shear Behavior of Large Concrete Beams Reinforced with High-Strength Steel," ACI Structural Journal, Vol. 105, No. 2, 2008, pp.173-179.
  15. Mast, R. F., Dawood, M., Rizkalla, S. H. and Zia, P., "Flexural Strength Design of Concrete Beams Reinforced with High-Strength Steel Bars," ACI Structural Journal, Vol. 105, No. 4, 2008, pp.570-577.
  16. McHarg, P. J., Cook, W. D., Mitchell, D. and Yoon, Y.-S., "Benefits of Concentrated Slab Reinforcement and Steel Fibers on Performance of Slab-Column Connections," ACI Structural Journal, Vol. 97, No. 2, 2000, pp.225-234.
  17. MMFX Technologies Corporation, MMFX Steel Product Guide, MMFX Technologies Corporation of America, Las Vegas, NV, 2007, p.73.
  18. Morgan, D. R., Mindess, S. and Chen, L., "Testing and specifying toughness for fiber reinforced concrete and shotcrete," Proc., 2nd Univ. - Industry Workshop on Fiber-Reinforced Concrete and Other Advanced Composites - Fiber-Reinforced Concrete - Modern Developments, N. Banthia and S. Mindess, ed., Toronto, 1995, pp.29-50.
  19. Regan, P. E., "Symmetric Punching of Reinforced Concrete Slabs," Magazine of Concrete Research, Vol. 38, No. 136, 1986, pp.115-128. https://doi.org/10.1680/macr.1986.38.136.115
  20. Seliem, H. M. A., Behavior of Concrete Bridges Reinforced with High-Performance Steel Reinforcing Bars, Ph.D Thesis, Dept. of Civil, Construction and Environmental Engineering, North Carolina State University, Raleigh, NC, 2007, p.259.
  21. Seliem, H. M., Hosny, A., Rizkalla, S., Zia, P., Briggs, M., Miller, S., Darwin, D., Browning, J., Glass, G. M., Hoyt, K., Donnelly, K. and Jirsa, J. O., "Bond Characteristics of ASTM A1035 Steel Reinforcing Bars," ACI Structural Journal, Vol. 106, No. 4, 2009, pp.530-539.
  22. Sumpter, M. S., Rizkalla, S. H. and Zia, P., "Behavior of High-Performance Steel as Shear Reinforcement for Concrete Beams," ACI Structural Journal, Vol. 106, No. 2, 2009, pp.171-177.
  23. Whitney, C. S., "Ultimate Shear Strength of Reinforced Concrete Flat Slabs, Footings, Beams and Frame Members without Shear Reinforcement," ACI Journal, Proceedings, Vol. 54, No. 4, 1957, pp.265-298.