DOI QR코드

DOI QR Code

A Study on the Failure Analysis and Representation Test Method of High Frequency Transformer for SMPS

SMPS용 고주파 트랜스의 고장의 분석 및 재현시험법에 관한 연구

  • 임홍우 (한국기계전기전자시험연구원) ;
  • 이영주 (한국기계전기전자시험연구원) ;
  • 한지훈 (한국기계전기전자시험연구원)
  • Received : 2010.10.07
  • Accepted : 2011.01.11
  • Published : 2011.04.01

Abstract

In this paper, we describe the failure analysis and representation test method that applied high frequency transformer for SMPS through analysing insulation resistance, frequency characteristic, CT analysis, Q-factor atc. And we study the judgement method that a high frequency transformer affects to other beside parts in different condition or environment. According to this method, we devise a plan for the field failure prevent and propose the securing product reliability of high frequency transformer.

Keywords

References

  1. Transformer Engineering Design and Practice, S.V, Kulkarni, S.A. Khaparde, 2004
  2. Rational fault analysis, edited by Richard Seaks and S. R. Liberty
  3. Transformer and Inductor Design handbook, Colonel Wm. T. McLyman
  4. B. Lu, W. Liu, Y. Liang, F. C. Lee, J. D. Van Wyk, "Optimal design methodology for LLC resonant converter", IEEE, pp. 533-538, 2006
  5. Sang-Gab park, Sang-Kyu han, Chung-Wook Roh, Sung-Soo Hong, " A High Efficiency Multi Output PDP Power System with Single Transformer Structore", 전력전자학회 학술대회 논문집, pp. 280-282, 2007

Cited by