DOI QR코드

DOI QR Code

General Steady-State Shape Factors in Analyzing Slug Test Results to Evaluate In-situ Hydraulic Conductivity of Vertical Cutoff Wall

순간변위시험(slug test)시 연직차수벽의 현장투수계수를 산정하기 위한 형상계수 연구

  • Lim, Jee-Hee (School of Civil. Environmental and Architectural. Engineering. Korea Univ.) ;
  • Lee, Dong-Seop (School of Civil, Environmental and Architectural. Engineering, Korea Univ.) ;
  • Nguyen, Thebao (School of Civil, Environmental and Architectural. Engineering, Korea Univ.) ;
  • Choi, Hang-Seok (School of Civil, Environmental and Architectural. Engineering, Korea Univ.)
  • 임지희 (고려대학교 건축사회환경공학부) ;
  • 이동섭 (고려대학교 건축사회환경공학부) ;
  • 윙 테 바오 (고려대학교 건축사회환경공학부) ;
  • 최항석 (고려대학교 건축사회환경공학부)
  • Received : 2011.08.11
  • Accepted : 2011.10.21
  • Published : 2011.10.31

Abstract

No analytical solution exists for evaluating in-situ hydraulic conductivity of vertical cutoff walls by analyzing slug test results. Recently, an analytical solution to interpret slug tests has been proposed for a partially penetrated well in an aquifer. However, this analytical solution cannot be directly applied to the cutoff wall because the solution has been developed exclusively for an infinite aquifer instead of a narrow cutoff wall. To consider the cutoff wall boundary conditions, the analytical solution has been modified in this study to take into account the narrow boundaries by introducing the imaginary well theory. Two boundary conditions are considered according to the existence of filter cakes: constant head boundary and no flux boundary. Generalized steady-state shape factors are presented for each geometric condition, which can be used for evaluating the in-situ hydraulic conductivity of cutoff walls. The constant head boundary condition provides higher shape factors and no flux boundary condition provides lower shape factors than the infinite aquifer, which enables to adjust the in-situ hydraulic conductivity of the cutoff wall. The hydraulic conductivities calculated from the analytical solution in this paper give about 1.2~1.7 times higher than those from the Bouwer and Rice method, one of the semi-empirical formulas. Considering the compressibility of the backfill material, the analytical solution developed in this study was proved to correspond to the case of incompressible backfill materials.

지금까지 순간 변위시험 (slug test)를 이용해 연직차수벽의 현장투수계수를 평가할 수 있는 이론해는 제시된 바가 없다. 최근 부분 관입된 우물(well)형상에 적용 가능한 이론해에 관한 연구가 발표되었으나, 이는 무한 경계조건인 대수층에만 국한되고 좁은 벽체형상의 연직차수벽의 경계 조건에는 그대로 적용될 수 없다. 이러한 연직차수벽 경계조건을 고려하기 위해, 본 연구에서는 가상 우물법(method of imaginary well)을 도입하여 기존 이론해를 수정하였다. 연직차수벽의 경계조건은 기존 문헌에서 제시한 두 가지 조건을 적용하였다. 첫 번째 경계조건은 연직차수벽 경계에 일정 수두 조건을 적용하고, 두 번째는 경계면에 불투수 경계조건을 적용하였다. 본 논문에서는 연직차수벽의 현장투수계수를 평가할 수 있도록 각 경계조건에 대하여 정상 상태 조건에 대한 일반적인 형상계수를 제시하였다. 첫 번째 경계조건의 경우, 연직차수벽의 투수계수가 연직차수벽이 존재하지 않는 대수층 조건보다 크게 평가되었으며, 두 번째 방법의 경우는 더 작게 평가되었다. 본 연구에서 제시한 수정 이본해를 통해 얻어진 투수계수는 경험식을 바탕으로 무한 대수층에 적용하기 위해 제안된 Bouwer and Rice 방법을 보정하여 다양한 연직차수벽 경계조건에 대해 실제 현장투수계수가 Bouwer and Rice 방법에 의한 결과 보다 1.2~1.7배 큼을 확인하였다. 또한, 연직차수벽 뒷채움재의 압축성을 고려한 기존 해석결과와 비교로부터, 본 논문에서 제시한 이론해는 뒷채움재가 비압축성에 상응하는 값을 제시하는 것을 확인할 수 있었다.

Keywords

References

  1. Bouwer, H. (1989), "The Bouwer and Rice slug test-An update", Ground Water, Vol.27, No.3, pp.304-309. https://doi.org/10.1111/j.1745-6584.1989.tb00453.x
  2. Bouwer, H. and Rice, R. C. (1976), "A slug test for determining hydraulic conductivity of unconfined aquifer with completely or partially penetrating wells", Water Resour. Res., Vol.12, No.3, pp.423-428. https://doi.org/10.1029/WR012i003p00423
  3. Britton, J. P., Filz, G. M., and Little, J. C. (2002). "Shape factors for single-well tests in soil-bentonite cutoff walls", Proc., 4th Int. Congress on Environmental Geotechnics, de Mello and Almeida, eds., pp.639-644.
  4. Butler, J. J. (1996). "Slug tests in situ characterization: Some practical consideration", Envir. Geosciences, Vol.3, No.2, p.154.
  5. Choi, H. (2007). "Numerical model for analyzing slug tests in vertical cutoff walls", J. Geotech. Geoenviron. Eng., ASCE Vol.133, No.10, pp.1249-1258. https://doi.org/10.1061/(ASCE)1090-0241(2007)133:10(1249)
  6. Choi, H., and Daniel, D. E. (2006a). "Slug test analysis in vertical cutoff walls. I: Analysis Methods", J. Geotech. Geoenviron. Eng., ASCE Vol.132, No.4, pp.429-438. https://doi.org/10.1061/(ASCE)1090-0241(2006)132:4(429)
  7. Choi, H., and Daniel, D. E. (2006b). "Slug test analysis in vertical cutoff walls. II: Applications", J. Geotech. Geoenviron. Eng., ASCE Vol.132, No.4, pp.439-447. https://doi.org/10.1061/(ASCE)1090-0241(2006)132:4(439)
  8. Choi, H., Nguyen, T. B., and Lee, C. (2008), "Slug test analysis to evaluate permeability of compressible materials", Ground Water, Vol.46, No.4, pp.647-652. https://doi.org/10.1111/j.1745-6584.2008.00453.x
  9. Dagan, G. (1978), "A note on packer, slug, and recovery tests in unconfined aquifers", Water Resources Research 14, No.5, pp.929-934. https://doi.org/10.1029/WR014i005p00929
  10. EMCON. (1995), M-11/15, M-17/21, and M-26/E-29 Slurry Walls Post Construction Performance Evaluation, West Contra Costa Sanitary Landfill, Richmond, Ca.
  11. Jacob B. (1979), "Hydraulics of Ground water", McGraw-Hill.
  12. Nguyen, T. B., Lee, C., Choi, H. (2011) "Slug test analysis in vertical cutoff walls with consideration of filter cake", J. Geotech. Geoenviron. Eng., ASCE, in print.
  13. Teeter, R. M., and Clemence, S. P. (1986). "In-place permeability measurement of slurry trench cutoff wall", Proc., In Situ' 86, Use of In Situ Tests in Geotechnical Engineering, GSP No.6, pp.1049-1061.
  14. Yang, D. S., Luscher, U., Kimoto, I., and Takeshima, S. (1993). "SMW wall for seepage control in levee reconstruction", Proc., 3rd Int. Conf. on Case Histories in Geotechnical Engineering, pp.487-492.
  15. Zlotnik, V, A., Goss, D. and Duffield, G. M. (2010), "General Steady-State Shape Factor for a Partially Penetrating Well", Ground Water, Vol.48, No.1, pp.111-116. https://doi.org/10.1111/j.1745-6584.2009.00621.x
  16. 웽 테 바오, 이철호, 최항석, 김상균 (2008), 필터케이크(filter cake)를 고려한 슬러리월 연직차수벽의 현장투수계수 평가, 한국지반공학회 논문집, 제24권 제11호, pp.121-131.
  17. 최항석, 이철호, 웽 테 바오 (2007), 압축성이 큰 지반에서 순간 변위(충격)시험 해석을 위한 선형 커브피팅법(Linear curve fitting method)의 적용, 한국지반공학회 논문집, 제23권 제11호, pp.1-9.