Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone

접선유입식과 축상유입식 사이클론의 집진효율 비교

  • 이중섭 (경상대학교 BK21(첨단기계)) ;
  • 이치우 (경남과학기술대학교 자동차공학부)
  • Received : 2011.09.23
  • Accepted : 2011.12.06
  • Published : 2011.12.31

Abstract

This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

Keywords

References

  1. Copper. C. D. and Alley F. C., "Air Pollution Control: A Design Approach", Waveland Press, New York, pp. 138-150, 1994.
  2. Zhou. L. X. and Soo. S. L., "Gas-Solid Flow and Collection of Solids in a Cyclone Separator", Powder Technology, Vol. 63, pp. 45-53, 1990. https://doi.org/10.1016/0032-5910(90)80006-K
  3. Song. E. Y., Park. J. Y., Jang. D. S., "A Numerical Study for the Performance Analysis of Axial - Vane Type Cyclone Dust Collector", KSWM, Vol. 11, No. 1, pp. 17-28, 1994.
  4. Kim. J. S., Lee. T. U., Kang. T. H., Kim. I. K., Kim. Y. S., "A CFD Analysis on Axial Inlet Cyclone using Realizable k-${\varepsilon}$ Turbulence Model", Conference Proceedings of KSME Spring Annual Meeting, pp. 1327-1332, 2006.
  5. Ju. J. I., Choi. Y. S., Lee. Y. K., Kim. T. H. and Kim. S. Y., "Numerical Stydy of Turbulent Flow in a Hydrocyclone", Journal of Flow Machinery, Vol. 6, No. 2, pp. 34-40, 2003. https://doi.org/10.5293/KFMA.2003.6.2.034
  6. Young. J. K., Kim. C. N. and Jo. Y. M., "A Numerical Analysis on the Flow Characteristics and the Collection Efficiency for Fine Particles in a Cyclone", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 20, No. 2, pp. 144-153, 2008.
  7. Cho. Y. S., Lee. S. W., Woo. K. S., Yoon. Y. B., Park. Y. J., Lee. D. Y., Kim. H. C. and Na. B. C., "A Numerical Analysis of Flow Characteristics and Oil Separation Performance for Cyclone Oil separator designs", Transactions of KSAE, Vol. 16, No. 5, pp. 22-28, 2008.
  8. Shin. H. J., Lee. Y. W., Park. J. H., Kim. J. H., Lee. C. W. and Jang. S. C., "A Numerical Study on the Performance Analysis for Design Optimization of Axial-Vane Type Cyclone", Proceedings of the KSMTE Spring Annual Meeting, pp. 537-538, 2011.
  9. Lapple. C. E. and Shepherd. C. B., "Flow pattern and pressure drop in dust cyclone separator", Ind. & Eng. Chem., Vol. 31 No. 8, pp. 972-984, 1939. https://doi.org/10.1021/ie50356a012