DOI QR코드

DOI QR Code

The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience

  • Moon, Joon-Ho (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Park, Eun-Ah (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Lee, Whal (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Yin, Yong-Hu (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Chung, Jin-Wook (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Park, Jae-Hyung (Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital) ;
  • Lee, Hae-Young (Department of Internal Medicine and the Cardiovascular Center, Seoul National University Hospital) ;
  • Kang, Hyun-Jae (Department of Internal Medicine and the Cardiovascular Center, Seoul National University Hospital) ;
  • Kim, Hyo-Soo (Department of Internal Medicine and the Cardiovascular Center, Seoul National University Hospital)
  • Published : 2011.06.01

Abstract

Objective: We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. Materials and Methods: We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients who underwent invasive coronary angiography, the image quality, the diagnostic performance (sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV] for detecting significant stenosis ${\geq}$ 50% diameter) and the radiation exposure were evaluated. These values were compared between the groups with differing heart rates (HR): mean HR < 65 or ${\geq}$ 65 and HR variability (HRV) < 15 or ${\geq}$ 15. Results: Among the 729 patients, the CT reports showed no stenosis or insignificant coronary artery stenosis in 72%, significant stenosis in 26% and non-diagnostic in 2%. For the 131 patients who underwent invasive coronary angiography, 95% of the patients and 97% of the segments were evaluable, and the overall per-patient/per-segment sensitivity, the perpatient/per-segment specificity, the per-patient/per-segment PPV and the per-patient/per-segment NPV were 100%/90%, 71%/98%, 95%/88% and 100%/97%, respectively. The image quality was better in the HR < 65 group than in the HR ${\geq}$ 65 group (p = 0.001), but there was no difference in diagnostic performance between the two groups. The mean effective radiation doses were lower in the HR < 65 or HRV < 15 group (p < 0.0001): 5.5 versus 6.7 mSv for the mean HR groups and 5.3 versus 9.3 mSv for the HRV groups. Conclusion: Dual-source CT coronary angiography is a highly accurate modality in the clinical setting. Better image quality and a significant radiation reduction are being rendered in the lower HR group.

Keywords

References

  1. Achenbach S, Ropers D, Kuettner A, Flohr T, Ohnesorge B, Bruder H, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience. Eur J Radiol 2006;57:331-335 https://doi.org/10.1016/j.ejrad.2005.12.017
  2. Johnson TR, Nikolaou K, Wintersperger BJ, Leber AW, von Ziegler F, Rist C, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol 2006;16:1409-1415 https://doi.org/10.1007/s00330-006-0298-y
  3. Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 2006;16:2739-2747 https://doi.org/10.1007/s00330-006-0474-0
  4. Burgstahler C, Reimann A, Drosch T, Heuschmid M, Brodoefel H, Tsiflikas I, et al. Cardiac dual-source computed tomography in patients with severe coronary calcifications and a high prevalence of coronary artery disease. J Cardiovasc Comput Tomogr 2007;1:143-151 https://doi.org/10.1016/j.jcct.2007.09.003
  5. Heuschmid M, Burgstahler C, Reimann A, Brodoefel H, Mysal I, Haeberle E, et al. Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease. Am J Cardiol 2007;100:587-592 https://doi.org/10.1016/j.amjcard.2007.03.066
  6. Johnson TR, Nikolaou K, Busch S, Leber AW, Becker A, Wintersperger BJ, et al. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol 2007;42:684-691 https://doi.org/10.1097/RLI.0b013e31806907d0
  7. Leber AW, Johnson T, Becker A, von Ziegler F, Tittus J, Nikolaou K, et al. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 2007;28:2354-2360 https://doi.org/10.1093/eurheartj/ehm294
  8. Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology 2007;245:703-711 https://doi.org/10.1148/radiol.2453070094
  9. Ropers U, Ropers D, Pflederer T, Anders K, Kuettner A, Stilianakis NI, et al. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 2007;50:2393-2398 https://doi.org/10.1016/j.jacc.2007.09.017
  10. Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, et al. Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 2008;247:346-355 https://doi.org/10.1148/radiol.2472070906
  11. Donnino R, Jacobs JE, Doshi JV, Hecht EM, Kim DC, Babb JS, et al. Dual-source versus single-source cardiac CT angiography: comparison of diagnostic image quality. AJR Am J Roentgenol 2009;192:1051-1056 https://doi.org/10.2214/AJR.08.1198
  12. Fang XM, Chen HW, Hu XY, Bao J, Chen Y, Yang ZY, et al. Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography. Int J Cardiovasc Imaging 2010;26:323-331
  13. Meng L, Cui L, Cheng Y, Wu X, Tang Y, Wang Y, et al. Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol 2009;10:347-354 https://doi.org/10.3348/kjr.2009.10.4.347
  14. Rixe J, Rolf A, Conradi G, Moellmann H, Nef H, Neumann T, et al. Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography. Circ J 2009;73:316-322 https://doi.org/10.1253/circj.CJ-08-0534
  15. Tsiflikas I, Brodoefel H, Reimann AJ, Thomas C, Ketelsen D, Schroeder S, et al. Coronary CT angiography with dual source computed tomography in 170 patients. Eur J Radiol 2010;74:161-165 https://doi.org/10.1016/j.ejrad.2009.01.039
  16. Weustink AC, Neefjes LA, Kyrzopoulos S, van Straten M, Neoh Eu R, Meijboom WB, et al. Impact of heart rate frequency and variability on radiation exposure, image quality, and diagnostic performance in dual-source spiral CT coronary angiography. Radiology 2009;253:672-680 https://doi.org/10.1148/radiol.2533090358
  17. Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Suss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006;16:256-268 https://doi.org/10.1007/s00330-005-2919-2
  18. Burgstahler C, Reimann A, Brodoefel H, Daferner U, Herberts T, Tsiflikas I, et al. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography. Eur Radiol 2009;19:584-590 https://doi.org/10.1007/s00330-008-1201-9
  19. McCollough CH, Primak AN, Saba O, Bruder H, Stierstorfer K, Raupach R, et al. Dose performance of a 64-channel dualsource CT scanner. Radiology 2007;243:775-784 https://doi.org/10.1148/radiol.2433061165
  20. Stolzmann P, Scheffel H, Schertler T, Frauenfelder T, Leschka S, Husmann L, et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 2008;18:592-599 https://doi.org/10.1007/s00330-007-0786-8
  21. Weustink AC, Mollet NR, Pugliese F, Meijboom WB, Nieman K, Heijenbrok-Kal MH, et al. Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography. Radiology 2008;248:792-798 https://doi.org/10.1148/radiol.2483072098
  22. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975;51:5-40 https://doi.org/10.1161/01.CIR.51.4.5
  23. Gouya H, Varenne O, Trinquart L, Touze E, Vignaux O, Spaulding C, et al. Coronary artery stenosis in high-risk patients: 64-section CT and coronary angiography--prospective study and analysis of discordance. Radiology 2009;252:377-385 https://doi.org/10.1148/radiol.2522081271
  24. Hamon M, Morello R, Riddell JW. Coronary arteries: diagnostic performance of 16- versus 64-section spiral CT compared with invasive coronary angiography--meta-analysis. Radiology 2007;245:720-731 https://doi.org/10.1148/radiol.2453061899
  25. Wang Y, Vidan E, Bergman GW. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 1999;213:751-758 https://doi.org/10.1148/radiology.213.3.r99dc41751

Cited by

  1. 80-kVp CT Using Iterative Reconstruction in Image Space Algorithm for the Detection of Hypervascular Hepatocellular Carcinoma: Phantom and Initial Clinical Experience vol.13, pp.2, 2011, https://doi.org/10.3348/kjr.2012.13.2.152
  2. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Sp vol.13, pp.6, 2011, https://doi.org/10.3348/kjr.2012.13.6.684
  3. Vascular Calcifying Progenitor Cells Possess Bidirectional Differentiation Potentials vol.11, pp.4, 2011, https://doi.org/10.1371/journal.pbio.1001534
  4. Incremental prognostic value of sequential imaging of single-photon emission computed tomography and coronary computed tomography angiography in patients with suspected coronary artery disease vol.15, pp.8, 2011, https://doi.org/10.1093/ehjci/jeu010
  5. The Diagnostic Performance of Coronary Artery Angiography with 64-MSCT and Post 64-MSCT: Systematic Review and Meta-Analysis vol.9, pp.1, 2011, https://doi.org/10.1371/journal.pone.0084937
  6. Prognostic Value of Renal Function for Cardiac Events in Patients Without Significant Stenosis on Coronary Computed Tomography Angiography vol.30, pp.9, 2011, https://doi.org/10.3346/jkms.2015.30.9.1273
  7. Review of the Use of Ionizing Radiation in Endovascular Aneurysm Repair vol.66, pp.7, 2011, https://doi.org/10.1177/0003319714548564
  8. Does the Reporting Quality of Diagnostic Test Accuracy Studies, as Defined by STARD 2015, Affect Citation? vol.17, pp.5, 2016, https://doi.org/10.3348/kjr.2016.17.5.706
  9. Diagnostic Accuracy of Dual-Source Computerized Tomography Coronary Angiography in Symptomatic Patients Presenting to a Referral Cardiovascular Center During Daily Clinical Practice vol.13, pp.2, 2011, https://doi.org/10.5812/iranjradiol.24350
  10. Coronary Computed Tomography Angiography for the Diagnosis of Vasospastic Angina: Comparison with Invasive Coronary Angiography and Ergonovine Provocation Test vol.20, pp.5, 2011, https://doi.org/10.3348/kjr.2018.0847
  11. Association and Prediction of Subclinical Atherosclerosis by Nonalcoholic Fatty Liver Disease in Asymptomatic Patients vol.2020, pp.None, 2011, https://doi.org/10.1155/2020/8820445
  12. Equivalent 10-year angiographic and long-term clinical outcomes with saphenous vein composite grafts and arterial composite grafts vol.162, pp.5, 2021, https://doi.org/10.1016/j.jtcvs.2020.01.109