DOI QR코드

DOI QR Code

전기투석을 이용한 구리이온의 제거 시 운전인자의 영향

Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis

  • 정효상 (동의대학교 환경공학과) ;
  • 이강춘 (동의대학교 화학공학과)
  • Jung, Hyo-Sang (Department of Environmental Engineering, Dong-eui University) ;
  • Lee, Gangchoon (Department of Chemical Engineering, Dong-eui University)
  • 투고 : 2010.10.04
  • 심사 : 2010.11.04
  • 발행 : 2011.01.30

초록

To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

키워드

참고문헌

  1. 김경수, 김석환, 정일현(2001). 전기투석장치에 의한 Ni 도금 폐수의 처리 특성. 한국환경분석학회지, 4(4), pp. 241-249.
  2. 김금용, 백주현(2009). 이상일, 부유 및 부착성장 질화균에 미치는 구리 독성의 영향. 대한환경공학회지, 31(10), pp. 855-864.
  3. 김영철(2007). 특정수질유해물질 구리(Cu)의 수계에서의 현황 및 관리방향. 수질보전 한국물환경학회지, 23(4), pp. 440-447.
  4. 양재규, 이남희, 이승목(2008). pH를 달리하여 제조한 3가철첨착 활성탄에 의한 구리 제거특성 평가. 대한환경공학회지, 30(3), pp. 345-351.
  5. 윤영상, 최순범, 원성욱(2004). 중금속 폐수처리를 위한 기술개발 현황 및 장단점 분석. DICER TechInfo Part 1, 3(7), pp. 68-85.
  6. Cowan, D. A. and Brown, J. H. (1959). Effect of Turbulent on Limiting Current in Electrodialysis Cells. Ind. Eng. Chem., 51, pp. 1445-1448. https://doi.org/10.1021/ie50600a026
  7. Martin, C. J., Kartinen Jr. E. O., and Condon, J. (1995). Examination of processes for multiple contaminant removal from groundwater. Desalination, 102, pp. 35-45. https://doi.org/10.1016/0011-9164(95)00039-5
  8. Sata, T. (2004). Ion Exchange Membranes: Preparation, Characterization, Modification and Application, The Royal Society of Chemistry, Cambridge, UK, pp. 215-250.
  9. Strathmann, H. (2004). Ion Exchange Membrane Separation Processes, Membrane Science and Technology Series, 9, Elsevier B. V., Amsterdam, Netherlands, pp. 147-184.
  10. Tanaka, Y. (2002). Current Density Distribution, Limiting Current Density and Saturation Current Density in an Ion-exchange Membrane Electrodialyzer. J. Membrane Sci., 210, pp. 65-75. https://doi.org/10.1016/S0376-7388(02)00376-9
  11. Tanaka, Y. (2003). Concentration Polarization in Ion-exchange Membrane Electrodialysis-the Events Arising in a Flowing Solution in a Desalting Cell. J. Membrane Sci., 216, pp. 149-164. https://doi.org/10.1016/S0376-7388(03)00067-X