참고문헌
- Parvizi J, Kim KI, Goldberg G, Mallo G, Hozack WJ. Recurrent instability after total hip arthroplasty: beware of subtle component malpositioning. Clin Orthop Relat Res. 2006;447:60-5.
- Bonutti PM, Zywiel MG, Seyler TM, et al. Minimally invasive total knee arthroplasty using the contralateral knee as a control group: a case-control study. Int Orthop. 2010;34:491-5. https://doi.org/10.1007/s00264-009-0775-4
- Bargar WL, Bauer A, Borner M. Primary and revision total hip replacement using the Robodoc system. Clin Orthop Relat Res. 1998;354:82-91.
- Paul HA, Bargar WL, Mittlestadt B, et al. Development of a surgical robot for cementless total hip arthroplasty. Clin Orthop Relat Res. 1992;285:57-66.
- Stulberg SD, Loan P, Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am. 2002;84-A Suppl 2:90-8.
- Dalury DF, Dennis DA. Mini-incision total knee arthroplasty can increase risk of component malalignment. Clin Orthop Relat Res. 2005;440:77-81. https://doi.org/10.1097/01.blo.0000185757.17401.7b
- Saxler G, Marx A, Vandevelde D, et al. The accuracy of free-hand cup positioning--a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop. 2004;28:198-201.
- Kalteis T, Handel M, B?this H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006;88:163-7. https://doi.org/10.1302/0301-620X.88B2.17163
- Leenders T, Vandevelde D, Mahieu G, Nuyts R. Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg. 2002;7:99-106. https://doi.org/10.3109/10929080209146021
- Honl M, Dierk O, Gauck C, et al. Comparison of roboticassisted and manual implantation of a primary total hip replacement. A prospective study. J Bone Joint Surg Am. 2003;85-A:1470-8.
- Kwoh YS, Hou J, Jonckheere EA, Hayati S. A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery. IEEE Trans Biomed Eng. 1988;35:153-60. https://doi.org/10.1109/10.1354
- Nishihara S, Sugano N, Nishii T, et al. Clinical accuracy evaluation of femoral canal preparation using the ROBODOC system. J Orthop Sci. 2004;9:452-61.
- Jakopec M, Harris SJ, Rodriguez y Baena F, Gomes P, Cobb J, Davies BL. The first clinical application of a "hands-on" robotic knee surgery system. Comput Aided Surg. 2001;6:329-39.
- Nolte LP, Zamorano L, Visarius H, et al. Clinical evaluation of a system for precision enhancement in spine surgery. Clin Biomech. 1995;10:293-303. https://doi.org/10.1016/0268-0033(95)00004-5
- Langlots U, Lawrens J, Hu Q, Langlotz F, Lolte LP. Image guided cup placement. In: Lemke HU, Vannier MW, Inamura K, Farman AG ed. Computer Assisted Radiology and Surgery. Amsterdam: Elsevier; 1999. 717-21.
- Digioia AM, Jaramaz B, Blackwell M, et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8-22.
- Hananouchi T, Sugano N, Nakamura N, et al. Preoperative templating of femoral components on plain X-rays. Rotational evaluation with synthetic X-rays on ORTHODOC. Arch Orthop Trauma Surg. 2007;127:381-5. https://doi.org/10.1007/s00402-007-0349-0
- Dorr LD, Malik A, Wan Z, Long WT, Harris M. Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res. 2007;465:92-99.
- Ryan JA, Jamali AA, Bargar WL. Accuracy of computer navigation for acetabular component placement in THA. Clin Orthop Relat Res. 2010;468:169-77. https://doi.org/10.1007/s11999-009-1003-7
- Nishihara S, Sugano N, Nishii T, Miki H, Nakamura N, Yoshikawa H. Comparison between hand rasping and robotic milling for stem implantation in cementless total hip arthroplasty. J Arthroplasty. 2006;21:957-66. https://doi.org/10.1016/j.arth.2006.01.001
- Nakamura N, Sugano N, Nishii T, Kakimoto A, Miki H. A comparison between robotic-assisted and manual implantation of cementless total hip arthroplasty. Clin Orthop Relat Res. 2010;468:1072-81. https://doi.org/10.1007/s11999-009-1158-2
- Prymka M, Wu L, Hahne HJ, Koebke J, Hassenpflug J. The dimensional accuracy for preparation of the femoral cavity in HIP arthroplasty. A comparison between manual- and robot-assisted implantation of hip endoprosthesis stems in cadaver femurs. Arch Orthop Trauma Surg. 2006;126:36-44. https://doi.org/10.1007/s00402-005-0080-7
- Kelley TC, Swank ML. Role of navigation in total hip arthroplasty. J Bone Joint Surg Am. 2009;91 Suppl 1:153-8.
- Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007;89:494-9. https://doi.org/10.2106/JBJS.F.00529
- Beckmann J, Stengel D, Tingart M, Gotz J, Grifka J, Luring C. Navigated cup implantation in hip arthroplasty. Acta Orthop. 2009;80:538-44. https://doi.org/10.3109/17453670903350073