DOI QR코드

DOI QR Code

Simulation Study on the Performance Characteristics in the Solar Hybrid R744 Heat Pump for Residential Applications

주거용 태양열 하이브리드 이산화탄소 열펌프 시스템의 성능특성에 관한 해석적 연구

  • Received : 2011.07.26
  • Accepted : 2011.09.15
  • Published : 2011.10.10

Abstract

Simulation study on the operating characteristics in the solar hybrid R744 heat pump system for residential applications was carried out with heat pump operating temperature, outdoor temperature and solar radiation. As a result, collector operating time is decreased by 1.5 hours due to the increase of water temperature in the heat storage tank when the heat pump operating temperature rises. Heat pump operating time is reduced by 19.4% owing to the high temperature of a heat storage tank. Besides, indoor heating time is decreased from 10.3 to 5.5 hours as the indoor temperature increases from $3^{\circ}C$ to $11^{\circ}C$. In addition to, when the solar radiation rises from 10 to 20 MJ/$m^2$, the maximum outlet temperature of a solar collector is increased from $65^{\circ}C$ to $71^{\circ}C$.

Keywords

References

  1. Kuang, Y. H. and Wang, R. Z., 2006, Performance of a multi-functional direct-expansion solar assisted heat pump system, Journal of Korean Solar Energy Society, Vol. 80, No. 7, pp. 795-803. https://doi.org/10.1016/j.solener.2005.06.003
  2. Park, Y. C., Kim, J. Y. and Ko, G. S., 2007, A study on performance characteristics on hybrid heat pump system with solar energy as heat pump, Journal of Korean Solar Energy Society, Vol. 27, No. 1, pp. 47-54
  3. Back, N. C., Lee, J. K., Kim, H. J., Yang, Y. S., and Song, B. H., 2000, Experimental study on the solar assisted heat pump system, Proceeding of Korean Solar Energy Society Fall Annual Conference, pp. 76-82.
  4. Sun, K. H., Jung, H. C., Kim, K. S., and Kim, Y. G., 1988, Performance characteristics of expansion part solar panel of rool bond type on solar heat pump system with R-22 and R-407 refrigerant for school classroom heating, Proceeding of the Korean Solar Energy Society Conference, pp. 105-109.
  5. Kim, Y. K., Hwang, I. J., and Lee, T. W., 2005, A study on the application and design of the heating system with a solar assisted heat pump, Proceeding of the Korean Solar Energy Society Conference, pp. 83-99.
  6. Test report, 2007, Thermal siphon type vacuum tube solar collector(TZ58/1800-20U), Korea Institute of Energy Research, KIER-07-4-005.
  7. Sanchez, D., Torrella, E., Cabello, R., and Llopis, R., 2010, Influence of the superheat associated to a semihermetic compressor of a transcritical $CO_{2}$ refrigeration plant, Applied Thermal Engineering, Vol. 30, pp. 302-309. https://doi.org/10.1016/j.applthermaleng.2009.09.008
  8. Hwang, Y. W. and Kim, O. J., 2007, Experimental study on the $CO_{2}$ flow through electronic expansion valves, International Congress of Refrigeration, Beijing, pp. 1-8.
  9. Yoon, S. H., Kim, J. H., and Kim, M. S., 2004, Experimental studies on heat transfer and pressure drop characteristics during gas cooling process of carbon dioxide in the supercritical region, Journal of Korean Air-Conditioning and Refrigerating Engineering, Vol. 16, No. 6, pp. 538-545.
  10. Thome, J. R., El Hajal, J., and Cavallini, A., 2003, Condensation in horizontal tubes, Part 2 :new heat transfer model based on flow regimes, International Journal of Heat and Mass Transfer, Vol. 46, pp. 3365-3387. https://doi.org/10.1016/S0017-9310(03)00140-6
  11. Yoon, S. H., Cho, E. S., and Kim, M. S., 2004, Characteristics of evaporative heat transfer and pressure drop of carbon dioxide and correlation development near the critical point, Journal of Korean Air-Conditioning and Refrigerating Engineering, Vol. 16, No. 6, pp. 530- 537.
  12. Dittus, F. W. and Boelter, L. M. K., 1930, Heat transfer in automobile radiators of the tubular type, University of california publications of engineering, Vol. 2, pp. 443-461.
  13. Incropera, F. P. and DeWitt, D. P., 1996, Introduction to Heat Transfer, 3rd de., John Wiley and Sons.
  14. Wang, C. C., Lee, W. S., and Sheu, W. J., 2001, A comparative study of compact enhanced fin-and-tube heat exchangers, International Journal of Heat and Mass Transfer, Vol. 44, pp. 3565-3573. https://doi.org/10.1016/S0017-9310(01)00011-4
  15. Wang, C. C., Lee, W. S., Sheu, W. J., and Chang, Y. J., 2002, A comparison of the airside performance of the fin-and-tube heat exchangers in wet conditions; with and without hydrophilic coating, Applied Thermal Engineering, Vol. 22, pp. 267-278. https://doi.org/10.1016/S1359-4311(01)00090-4
  16. ASHRAE, 1983, Methods of testing for seasonal efficiency of unitary air-conditioner and heat pumps, ASHRAE Standard 116.
  17. Klein, S. A., 2004, Engineering Equation Solver( EES). IN:Klein, S. A.(Ed.), F-Chart Software, Madison

Cited by

  1. Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump vol.33, pp.2, 2013, https://doi.org/10.7836/kses.2013.33.2.001