DOI QR코드

DOI QR Code

3D Whole-Heart Coronary MR Angiography at 1.5T in Healthy Volunteers: Comparison between Unenhanced SSFP and Gd-Enhanced FLASH Sequences

  • Gweon, Hye-Mi (Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System) ;
  • Kim, Sang-Jin (Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System) ;
  • Lee, Sang-Min (Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System) ;
  • Hong, Yoo-Jin (Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System) ;
  • Kim, Tae-Hoon (Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System)
  • 발행 : 2011.12.01

초록

Objective: To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). Materials and Methods: Thirty healthy volunteers (M:F = 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. Results: The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. Conclusion: An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.

키워드

참고문헌

  1. Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 1993;328:828-832 https://doi.org/10.1056/NEJM199303253281202
  2. Weber OM, Martin AJ, Higgins CB. Whole-heart steadystate free precession coronary artery magnetic resonance angiography. Magn Reson Med 2003;50:1223-1228 https://doi.org/10.1002/mrm.10653
  3. Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ. Improved coronary artery definition with T2-weighted, freebreathing, three-dimensional coronary MRA. Circulation 1999;99:3139-3148 https://doi.org/10.1161/01.CIR.99.24.3139
  4. Johnson KR, Patel SJ, Whigham A, Hakim A, Pettigrew RI, Oshinski JN. Three-dimensional, time-resolved motion of the coronary arteries. J Cardiovasc Magn Reson 2004;6:663-673 https://doi.org/10.1081/JCMR-120038086
  5. Wang Y, Watts R, Mitchell I, Nguyen TD, Bezanson JW, Bergman GW, et al. Coronary MR angiography: selection of acquisition window of minimal cardiac motion with electrocardiography-triggered navigator cardiac motion prescanning--initial results. Radiology 2001;218:580-585 https://doi.org/10.1148/radiology.218.2.r01fe46580
  6. Hofman MB, Wickline SA, Lorenz CH. Quantification of inplane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification. J Magn Reson Imaging 1998;8:568-576 https://doi.org/10.1002/jmri.1880080309
  7. Wang Y, Vidan E, Bergman GW. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 1999;213:751-758 https://doi.org/10.1148/radiology.213.3.r99dc41751
  8. Finn JP, Nael K, Deshpande V, Ratib O, Laub G. Cardiac MR imaging: state of the technology. Radiology 2006;241:338-354 https://doi.org/10.1148/radiol.2412041866
  9. Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D. 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med 2001;46:494-502 https://doi.org/10.1002/mrm.1219
  10. Giorgi B, Dymarkowski S, Maes F, Kouwenhoven M, Bogaert J. Improved visualization of coronary arteries using a new threedimensional submillimeter MR coronary angiography sequence with balanced gradients. AJR Am J Roentgenol 2002;179:901-910 https://doi.org/10.2214/ajr.179.4.1790901
  11. Spuentrup E, Buecker A, Stuber M, Botnar R, Nguyen TH, Bornert P, et al. Navigator-gated coronary magnetic resonance angiography using steady-state-free-precession: comparison to standard T2-prepared gradient-echo and spiral imaging. Invest Radiol 2003;38:263-268
  12. Gerber BL, Coche E, Pasquet A, Ketelslegers E, Vancraeynest D, Grandin C, et al. Coronary artery stenosis: direct comparison of four-section multi-detector row CT and 3D navigator MR imaging for detection--initial results. Radiology 2005;234:98-108 https://doi.org/10.1148/radiol.2341031325
  13. Sakuma H, Ichikawa Y, Suzawa N, Hirano T, Makino K, Koyama N, et al. Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography. Radiology 2005;237:316-321 https://doi.org/10.1148/radiol.2371040830
  14. Nehrke K, Bornert P, Mazurkewitz P, Winkelmann R, Grasslin I. Free-breathing whole-heart coronary MR angiography on a clinical scanner in four minutes. J Magn Reson Imaging 2006;23:752-756 https://doi.org/10.1002/jmri.20559
  15. Stehning C, Bornert P, Nehrke K, Eggers H, Stuber M. Freebreathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 2005;54:476-480 https://doi.org/10.1002/mrm.20557
  16. Tang L, Merkle N, Schar M, Korosoglou G, Solaiyappan M, Hombach V, et al. Volume-targeted and whole-heart coronary magnetic resonance angiography using an intravascular contrast agent. J Magn Reson Imaging 2009;30:1191-1196 https://doi.org/10.1002/jmri.21903
  17. Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, et al. ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol 1999;33:1756-1824 https://doi.org/10.1016/S0735-1097(99)00126-6
  18. Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 2002;48:425-429 https://doi.org/10.1002/mrm.10240
  19. Zagrosek A, Noeske R, Abdel-Aty H, Friedrich MG, Dietz R, Schulz-Menger J. MR coronary angiography using 3D-SSFP with and without contrast application. J Cardiovasc Magn Reson 2005;7:809-814 https://doi.org/10.1080/10976640500287786
  20. Niendorf T, Hardy CJ, Giaquinto RO, Gross P, Cline HE, Zhu Y, et al. Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system. Magn Reson Med 2006;56:167-176 https://doi.org/10.1002/mrm.20923
  21. Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U, et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 2000;217:564-571 https://doi.org/10.1148/radiology.217.2.r00nv30564
  22. Weissler AM, Harris WS, Schoenfeld CD. Systolic time intervals in heart failure in man. Circulation 1968;37:149-159 https://doi.org/10.1161/01.CIR.37.2.149
  23. Gharib AM, Herzka DA, Ustun AO, Desai MY, Locklin J, Pettigrew RI, et al. Coronary MR angiography at 3T during diastole and systole. J Magn Reson Imaging 2007;26:921-926 https://doi.org/10.1002/jmri.21056
  24. Plein S, Jones TR, Ridgway JP, Sivananthan MU. Threedimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. AJR Am J Roentgenol 2003;180:505-512 https://doi.org/10.2214/ajr.180.2.1800505
  25. Iozzelli A, D'Orta G, Aliprandi A, Secchi F, Di Leo G, Sardanelli F. The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches. Eur J Radiol 2009;72:489-493 https://doi.org/10.1016/j.ejrad.2008.09.004
  26. Pereles FS, McCarthy RM, Baskaran V, Carr JC, Kapoor V, Krupinski EA, et al. Thoracic aortic dissection and aneurysm: evaluation with nonenhanced true FISP MR angiography in less than 4 minutes. Radiology 2002;223:270-274 https://doi.org/10.1148/radiol.2231010966
  27. Krishnam MS, Tomasian A, Malik S, Desphande V, Laub G, Ruehm SG. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases. Eur Radiol 2010;20:1311-1320 https://doi.org/10.1007/s00330-009-1672-3
  28. Bi X, Li D. Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography. J Magn Reson Imaging 2005;21:133-139 https://doi.org/10.1002/jmri.20250
  29. Bi X, Carr JC, Li D. Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent. Magn Reson Med 2007;58:1-7 https://doi.org/10.1002/mrm.21224
  30. Sommer T, Hackenbroch M, Hofer U, Schmiedel A, Willinek WA, Flacke S, et al. Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 2005;234:718-725 https://doi.org/10.1148/radiol.2343031784

피인용 문헌

  1. Optimizing the Imaging Protocol for Ex Vivo Coronary Artery Wall Using High-Resolution MRI: An Experimental Study on Porcine and Human vol.14, pp.4, 2011, https://doi.org/10.3348/kjr.2013.14.4.581
  2. 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium vol.29, pp.5, 2013, https://doi.org/10.1007/s10554-013-0192-z
  3. DETECTION OF MYOCARDIAL VIABILITY IN ISСHAEMIC DAMAGE USING MAGNETIC RESONANCE AND EMISSION TOMOGRAPHY vol.12, pp.6, 2011, https://doi.org/10.20538/1682-0363-2013-6-154-166
  4. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging vol.46, pp.13, 2016, https://doi.org/10.1007/s00247-016-3694-8