Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example

GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법

  • Kim, Byung-Yong (Department of Physics, College of Science, Yeungnam University) ;
  • Kim, Hyung-Dong (Department of Physics, College of Science, Yeungnam University) ;
  • Kim, Sung-Jin (Department of Physics, College of Science, Yeungnam University) ;
  • Oh, Se-An (Department of Physics, College of Science, Yeungnam University) ;
  • Kang, Jung-Gu (Department of Radiation Oncology, Presbyterian Medical Center) ;
  • Kim, Sung-Kyu (Department of Therapeutic Radiology & Oncology, College of Medicine, Yeungnam University)
  • 김병용 (영남대학교 이과대학 물리학과) ;
  • 김형동 (영남대학교 이과대학 물리학과) ;
  • 김성진 (영남대학교 이과대학 물리학과) ;
  • 오세안 (영남대학교 이과대학 물리학과) ;
  • 강정구 (전주예수병원 방사선종양학과) ;
  • 김성규 (영남대학교 의과대학 방사선종양학교실)
  • Received : 2011.05.16
  • Accepted : 2011.06.27
  • Published : 2011.06.30

Abstract

In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.

본 연구에서는 GEANT4 toolkit을 이용하여 의료용 선형가속기에 대한 몬테칼로(Monte Carlo) 전산모사를 하였다. Medical Linac2 예제를 수정해서 사용하였다. 에너지스펙트럼, 최빈에너지, 평균에너지를 EGS4 결과와 비교 하였고 선속의 중심에서부터 반경에 따른 단위면적당 광자수, 단위면적당 에너지, 평균에너지를 분석하였다. 그 결과 EGS4 결과와 큰 차이를 보이지 않기 때문에 Medical Linac2 예제의 선속특성에 관한 전산모사에 큰 문제점은 없는 것으로 판단된다. 같은 헤드구조에서도 Physics List의 모델에 따라서는 결과에 차이가 발생하므로 연구 환경에 알맞은 Physics List 모델을 선택하는 것이 중요하다고 판단된다. 본 연구는 처음 몬테칼로 전산모사를 접하는 사용자가 선속특성에 대한 전산모사를 수행하고 6 MV 광자선속의 특성을 분석하는 과정에 많은 도움이 될 것으로 사료된다.

Keywords

References

  1. Rebecca M. Howell, Stephen F. Kry, Eric Burgett, David Followill, Nolan E. Hertel: Effects of tertiary MLC configuration on secondary neutron spectra from 18 MV x-ray beams for the varian 21EX linear accelerator. Med Phys 36:4039-4046 (2009) https://doi.org/10.1118/1.3159301
  2. 강세권, 정광호, 주라형 등: 제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구. 의학물리 18:126-133 (2007)
  3. Kim HK, Han SJ, Kim JL, Kim BH, Chang SY, Lee JK: Monte Carlo simulation of the photon beam characteristics from medical linear accelerators. Radiation Protection Dosimetry 119:510-513 (2006) https://doi.org/10.1093/rpd/nci636
  4. Nettelbeck H, Takacs GJ, Rosenfeld AB: Effect of transverse magnetic fields on dose distribution and RBE of photon beams: comparing PENELOPE and EGS4 Monte Carlo codes. Phys Med Biol 53:5123-5137 (2008) https://doi.org/10.1088/0031-9155/53/18/018
  5. Bruce AF, Makoto AJ, Joesph P, et al: Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies. Med Phys 35:4308-4317 (2008) https://doi.org/10.1118/1.2975150
  6. 강상구, 한동현, 김종일: GEANT4를 이용한 $^{99m}Tc$ Generator 안정성 시뮬레이션. 의학물리 19:11-18 (2008)
  7. Barbara Caccia, Claudio Andenna, Giuseppe Antonio Pablo Cirrone: MedLinac2: a GEANT4 based software package for radiotherapy. Ann 1st Super Sanita 46:173-177 (2010)
  8. Bjork P, Knöös T, Nilsson P: Influence of initial electron beam characteristics on monte carlo calculated absorbed dose distributions for linear accelerator electron beams. Phys Med Biol 21:4019-4041 (2002)
  9. Daryoush SB, Rogers DWO: Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med Phys 29:391-402 (2002) https://doi.org/10.1118/1.1445413
  10. Daryoush SB, Rogers DWO, Carl KR, et al: Comparison of measured and Monte Carlo calculated dose distributions from the NRC linac. Med Phys 27:2256-2266 (2000) https://doi.org/10.1118/1.1290714
  11. AAPM TG-105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys 34:4818-4853 (2007) https://doi.org/10.1118/1.2795842
  12. Grevillot L, Frisson T, Maneval D, Zahra N, Badel JN, Sarrut D: Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4. Phys Med Biol 56:903-918 (2011) https://doi.org/10.1088/0031-9155/56/4/002
  13. 정동혁, 김진기, 신교철 등: EGS5 기반 사용자코드의 작성과 초기 계산결과. 의학물리 17:123-129 (2006)