DOI QR코드

DOI QR Code

Evaluation on the Mechanical Properties of Strain Hardening Cement Composite by Mixing Method for Application at Building Construction Site

건축시공 현장적용을 위한 비빔방법에 따른 SHCC의 역학적 성능 평가

  • Received : 2011.04.30
  • Accepted : 2011.09.15
  • Published : 2011.09.28

Abstract

The purpose of this study is to examine material performance of fiber reinforced cement composite for mass production. It is necessary to manufacture SHCC(Strain Hardening Cement Composite) by batch plant for field application and mass production. For the study, a mock-up test of SHCC manufactured in the batch plant was conducted, and the performance was compared with SHCC manufactured in the laboratory. Assessment items were freshness and hardening properties. Specifically, direct tensile test machine was used for performance verification of SHCC. As a result, there was a tendency of less satisfactory fiber dispersion and performance of strain hardening compared with the performance of SHCC manufactured in the laboratory. To address this, dry mixing and mortar mixing time should be increased compared to laboratory mixing, and injection time of an agent such as a water reducing agent should be properly controlled according to mixing combination, or the capacity to secure dispersion and homogeneity of material.

연구는 SHCC의 건축시공 현장적용을 목적으로 현장 제조설비인 배치플랜트 2-Shaft 믹서를 이용하여 SHCC 제조 및 타설을 통해 실부재 실험을 실시하고, 이를 실내실험 결과와 비교 검토함으로서 향후 SHCC의 현장적용을 위한 기초자료로 제시하고자 하였다. 그 결과, 실내 Omni 믹서와 2-Shaft 믹서에서 SHCC 제조시 인장강도는 유사하였지만, 변형률에서 Omni 믹서가 2.5 % 이상 우수하였다. 배치플랜트 3500 L 2-Shaft 믹서에서 제조된 SHCC의 경우, 실내 100 L 2-Shaft 믹서에서 제조한 SHCC에서 인장 성능이 보다 높게 나타났다. SHCC의 현장적용 확대를 위해서는 배치플랜트 현장 제조시 건비빔, 모르타르 비빔시간을 충분히하여 매트릭스를 균질성을 확보하고, 비빔단계에서 적절한 점성 및 유동성을 확보할 수 있는 다양한 방법을 고려해야 한다.

Keywords

References

  1. Austin SA, Robins PJ, Goodier CI. The Rheological Performance of Wet-Process Sprayed Mortars. Magazine of Concrete Research. 1999 Oct;51(5):341-52. https://doi.org/10.1680/macr.1999.51.5.341
  2. Austin SA, Robins PJ, Goodier CI. The Performance of Hardend Wet-Process Sprayed Mortars. Magazine of Concrete Research. 2000 June;52(3):195-208. https://doi.org/10.1680/macr.2000.52.3.195
  3. Maalej M, Li VC. Flexural/Tensile Strength Ratio in Engineered Cementitious Composites. Journal of Materials in Civil Engineering. 1994 Nov;6(4):513-28. https://doi.org/10.1061/(ASCE)0899-1561(1994)6:4(513)
  4. Fischer G, Li VC. Intrinsic Response Control of Moment Resisting Frames Utilizing Advanced Composite Materials and Structural Elements. ACI Structural Journal. 2003 Mar;100(2):166-76.
  5. Krstulovic Opara N, Malak S. Micromechanical Tensile Behavior of Slurry Infiltrated Continuous-Fiber-Mat Reinforced Concrete(SIMCON). ACI Materials Journal. 1997 Sep;94(5):373-84.
  6. Li VC, Wang S, Wu C. Tensile Strain-Hardening Behavior of Polyvinyl Alcohol Engineered Cementitious Composite (PVA-ECC). ACI Materials Journal. 2001 Nov;98(6):483-92.
  7. Otter DE, Naaman A. Properties of Steel Fiber Reinforced Concrete Under Cyclic Loading. ACI Materials Journal. 1998 Jul;85(4):254-61.
  8. Rossi P. High Performance Multimodal Fiber Reinforced Cement Composites (HPMRFRCC). ACI Materials Journal. 1997 Nov;94(6):478-83.
  9. Zheng W, Kwan AH, Lee PK. Direct Tension Test of Concrete. ACI Materials Journal. 2001 Jan;98(1):63-71.
  10. Kim YY, Kong HJ, Li VC. Design of Engineered Cementitous Composite Suitable for Wet-Mixture Shotcreting. ACI Materials Journal. 2003 Nov;100(6):511-8.

Cited by

  1. Attempts to apply high performance fiber-reinforced cement composite (HPFRCC) to infrastructures in South Korea vol.109, 2014, https://doi.org/10.1016/j.compstruct.2013.10.027