DOI QR코드

DOI QR Code

Effect on Vibration of Start-up Condition and Retrofit of Steam Turbines

증기터빈의 기동조건과 성능개선이 터빈의 진동에 미치는 영향

  • 이혁순 (한국수력원자력 원자력발전기술원) ;
  • 정혁진 (한국수력원자력 원자력발전기술원) ;
  • 송우석 (한국수력원자력 원자력발전기술원)
  • Received : 2011.07.28
  • Accepted : 2011.08.08
  • Published : 2011.09.01

Abstract

The analysis shows that the vibration is one of the main reasons of turbine failure. Especially, the problems caused by vibration occur right after retrofit of the turbine-generator and restarting the turbine. Through the case study of high vibration caused by after the turbine trip and restart, turbine vibration was identified to be influenced by startup condition. Turbine startup at high casing temperature right after unscheduled turbine trip cause radial expansion in rotor by contraction in axial direction, while casing continues to contract by steam flowing into casing. Consequently, gap between rotor and casing decrease until to metal contact to cause high vibration. Through the case study of high vibration of turbine-generator system after generator retrofit, it was identified that generator replacement could cause high vibration in turbine-generator system if the influence of generator replacement on entire system was not considered properly. To prevent startup delay caused by high vibration, it is important to keep the gaps at the design standard and start the turbine after thermal equilibrium.

Keywords