DOI QR코드

DOI QR Code

Prediction of Equivalent Stress Block Parameters for High Strength Concrete

고강도 콘크리트의 등가응력 매개변수 추정에 관한 연구

  • 이도형 (배재대학교 건설환경철도공학과) ;
  • 전정문 (배재대학교 토목환경공학과) ;
  • 정민철 (고려대학교 건축사회환경공학부) ;
  • 공정식 (고려대학교 건축사회환경공학부)
  • Received : 2010.10.29
  • Accepted : 2011.03.11
  • Published : 2011.06.30

Abstract

Recently, a high strength concrete of more than 40 MPa has been increasingly used in practice. However, use of the high strength concrete may influence on design parameters, particularly stress distribution. This is very true since the current everyday practice employs equivalent rectangular stress distribution that is derived from normal strength concrete. Subsequently, the stress distribution seems to be reevaluated and then a new distribution with new parameters needs to be suggested for the high strength concrete. For this purpose, linear and multiple regression analyses have been carried out in term of using experimental data for the high strength concrete of 40 to 80 MPa available in literatures. Accordingly, new parameters associated with the stress distribution have been proposed and employed for the design of flexural and compressive members. Comparative design examples indicate that designs with new parameters reduce section dimensions compared to those with the current code parameters for concrete strengths of 40 to 70 MPa. In particular, for compressive members, design with new parameters exhibit conservative compressive force compared to those with the current code parameters.

최근 들어 고강도 콘크리트의 사용이 꾸준히 증가하고 있지만 현행 국내 콘크리트구조설계기준은 보통강도 콘크리트에 기초한 등가직사각형 응력매개변수를 사용하고 있어 응력분포가 일반 강도 콘크리트와 상이한 고강도 콘크리트의 설계 시 문제점을 야기할 수 있다. 따라서 이러한 문제점을 극복하기 위해서는 고강도 콘크리트에 대한 새로운 등가응력 매개변수 값이 제시되어져야 할 것으로 판단된다. 본 연구에서는 새로운 등가응력 매개변수를 제안하기 위해 기존 연구자들의 실험데이터를 토대로 선형 및 다중회귀분석을 수행하여 40~80 MPa 까지의 고강도 콘크리트에 대한 등가응력 매개변수를 이론적으로 추정하고 제안된 등가응력모델을 휨과 압축 부재설계에 적용시켜 기존의 국내 콘크리트구조설계기준과 비교검토 하였다. 제안된 등가응력모델로 구조설계를 수행한 결과, 콘크리트 강도 40~70 MPa 까지는 기존 모델에 비해 콘크리트 단면 감소 효과가 있었으며 또한 압축부재의 경우, 제안된 모델이 기존 모델 보다 콘크리트의 압축력을 더 보수적으로 평가하는 것으로 나타났다.

Keywords

References

  1. 이재훈, 손혁수, 김준범(1999) 고강도 철근 콘크리트 기둥의 실험 및 강도해석, 한국콘크리트학회논문집, 한국콘크리트학회, 제11권 1호, pp. 146-160.
  2. ACI 318-05 (2002) Building code requirements for structural concrete and commentary, american concrete institute, Farmington Hills, USA.
  3. ACI 318 TG-5 (2004) In the committee meeting, ACI fall conference, San Francisco, California.
  4. Canadian Standards Association (1994) Design of concrete structures in buildings, (CAN 3-A23.3-M94), Rexdale, Ontario, Canada.
  5. CEN, EN 1992 'Eurocode 2 (2004) Design of concrete structures', European Committee for Standardization.
  6. Hognestad, E., Hanson, N.W., and McHenry, D. (1955) Concrete stress distribution in ultimate strength design, ACI Journal. Proceedings, Vol. 52, pp. 455-479.
  7. Ibrahim, H.H.H. and MacGregor, J.G. (1997) Modification of the ACI Rectangular stress block for high-strength concrete, ACI Strucural Journal, Vol. 94, pp. 40-48.
  8. Kaar, P.H., Hanson, N.W., and Capell, H.T. (1978) Stress-strain characteristics of high strength concrete, American Concrete Institute Special Publication-55, Douglas McHenry International Symposium on Concrete and Concrete Structures, Michigan, pp. 161-185.
  9. Lee, J.-H. and Son, H.-S. (2000) Failure and strength of high-strength concrete columns subjected to eccentric loads, ACI Structural Journal, Vol. 97, No. 1, Jan-Feb. pp. 75-85.
  10. Nedderman, H. (1973) Flexural Stress Distribution in Very-High Strength Concrete, M.Sc. Thesis, Department of Civil Engineering, University of Texas at Arlington, Arlington, Texas.
  11. Pastor, J.A. (1986) High Strength Concrete Beams, Ph.D. Thesis, Department of Civil Engineering, Cornell University, Ithaca, New York.
  12. Standards New Zealand (1995) Design of concrete structure, (NZS 3101-1995), Wellington, New Zealand.
  13. Tan, T.H. and Nguyen, N. (2005) Flexural behavior of confined high-strength concrete columns, ACI Structural Journal, Vol. 102, No. 2, pp. 198-205.