Abstract
The purpose of this study is to suggest installation methods of a mobile-communication repeater into a lift system with consideration of EMC. Two approaches, one(Solution 1) is realized with a repeater installed in a lift hoistway and another(Solution 2) installed inside a lift, were proposed. It is confirmed that the Solution 1 is more effective than the Solution 2. And it is suggested that the EIRP of a repeater must be limited to be ${\leq}$-5 dBm by considering electromagnetic immunity level for a lift and safety margin of 20 dB. This limit can provide suitable electromagnetic environment inside a lift with precise power-control mechanism of mobile communication systems. This study could be a good example of Green ICT by improving electromagnetic environment in spite of radio use.
본 연구의 목적은 전자파 적합성을 고려하여 승강기 시스템 내에 중계기 안테나를 설치하는 방안을 제안하는 것이다. 승강로에 중계기 안테나를 설치하는 경우(Solution 1)와 승강기 내부에 중계기 안테나를 설치하는 경우 (Solution 2)의 2가지 solutions을 검토하였으며, Solution 2가 Solution 1보다 효과적임을 확인하였다. 또한, 승강기에 대한 전자파 내성 기술 기준과 20 dB의 안전 마진을 고려하여 중계기 안테나의 출력(EIRP)을 -5 dBm으로 제한할 것을 제안하였으며, 이러한 출력은 이동 통신 시스템의 정밀 전력 제어 메커니즘에 따라 최적의 안정된 전자파 환경을 제공함을 확인하였다. 이러한 접근은 무선을 활용하여 오히려 전자파 환경을 개선할 수 있음을 보여준 본 연구가 Green ICT의 중요한 사례가 될 수 있다.