DOI QR코드

DOI QR Code

Numerical assessment of seismic safety of liquid storage tanks and performance of base isolation system

  • 투고 : 2008.12.02
  • 심사 : 2010.03.23
  • 발행 : 2010.08.20

초록

Seismic isolation is a well-known method to mitigate the earthquake effects on structures by increasing their fundamental natural periods at the expense of larger displacements in the structural system. In this paper, the seismic response of isolated and fixed base vertical, cylindrical, liquid storage tanks is investigated using a Finite Element Model (FEM), taking into account fluid-structure interaction effects. Three vertical, cylindrical tanks with different ratios of height to radius (H/R = 2.6, 1.0 and 0.3) are numerically analyzed and the results of response-history analysis, including base shear, overturning moment and free surface displacement are reported for isolated and non-isolated tanks. Isolated tanks equipped by lead rubber bearings isolators and the bearing are modeled by using a non-linear spring in FEM model. It is observed that the seismic isolation of liquid storage tanks is quite effective and the response of isolated tanks is significantly influenced by the system parameters such as their fundamental frequencies and the aspect ratio of the tanks. However, the base isolation does not significantly affect the surface wave height and even it can causes adverse effects on the free surface sloshing motion.

키워드

참고문헌

  1. American Petroleum Institute API (1998), "Welded storage tanks for oil storage", API 650, American Petroleum Institute Standard, Washington D.C.
  2. ANSYS Inc. (2005), ANSYS Multiphysics 10.0, Southpointe, 275 Technology Drive, Canonsburg, PA 15317.
  3. Chalhoub, M.S. and Kelly, J.M. (1988), "Theoretical and experimental studies of cylindrical water tanks in base isolated structures", Report No. UCB/EERC-88/07, Berkeley.
  4. Goudarzi, M.A. and Sabbagh-Yazdi, S.R. (2009), "Numerical Investigation on Accuracy of Mass Spring Models for Cylindrical Tanks under Seismic Excitation", Int. J. Civil Eng., 7(3), 190-202.
  5. Goudarzi, M.A., Sabbagh-Yazdi, S.R. and Marx, W. (2010), "Investigation of sloshing damping in baffled rectangular tanks under dynamic excitation", Bull. Earthq. Eng., 8(4), 1055. https://doi.org/10.1007/s10518-009-9168-8
  6. Goudarzi, M.A., Sabbagh-Yazdi, S.R. and Marx, W. (2010), "Seismic analysis of hydrodynamic sloshing force on storage tank roof", J. Earthq. Spect., 26(1), 131-152. https://doi.org/10.1193/1.3283902
  7. Haroun, M.A. and Housner, G.W. (1981), "Seismic design of liquid storage tanks", J. Tech. Counc., ASCE, 107(1), 191-207.
  8. Housner, G.W. (1954), "Earthquake pressures on fluid containers", Report No. 081-095, Eighth Technical Report under Office of Naval Research, Project Designation, California Institute of Technology, Pasadena, California.
  9. Housner, G.W. (1957), "Dynamic pressures on accelerated fluid containers", B. Seismol. Soc. Am., 47(1), 15-35.
  10. Housner, G.W. (1963), "Dynamic analysis of fluids in containers subjected to acceleration", Report No. TID 7024, Nuclear Reactors and Earthquakes, U.S. Atomic energy Commission, Washington D.C.
  11. Jadhav, M.B. and Jangid, R.S. (2006), "Response of base-isolated liquid storage tanks to near-fault motions", Struct. Eng. Mech., 23, 615-634. https://doi.org/10.12989/sem.2006.23.6.615
  12. Kelly, T.E. and Mayes, R.L. (1989), "Seismic isolation of storage tanks", Proceedings of Seismic Engineering: Research and Practice, ASCE, San Francisco, CA.
  13. Kim, N.S. and Lee, D.G. (1995), "Pseudo-dynamic test for evaluation of earthquake performance of base-isolated liquid storage tanks", Eng. Struct., 17(3), 198-208. https://doi.org/10.1016/0141-0296(95)00076-J
  14. Malhotra, P.K. (1997), "New methods for earthquake isolation of liquid-storage tanks", Earthq. Eng. Struct. D., 26, 839-847. https://doi.org/10.1002/(SICI)1096-9845(199708)26:8<839::AID-EQE679>3.0.CO;2-Y
  15. Malhotra, P.K. (2005), "Sloshing loads in tanks with insufficient freeboard", Earthq. Spect., 21, 1185-1192. https://doi.org/10.1193/1.2085188
  16. Malhotra, P.K. (2006), "Earthquake induced sloshing in tanks with insufficient freeboard", Struct. Eng. Int., 16, 222-225. https://doi.org/10.2749/101686606778026466
  17. Malhotra, P.K., Wenk, T. and Wieland, M. (2000), "Simple procedure for seismic analysis of liquid storage tanks", Struct. Eng. Int., 10(3), 197-201. https://doi.org/10.2749/101686600780481509
  18. Shenton, H.W. and Hampton, F.P. (1999), "Seismic response of isolated elevated water tanks", J. Struct. Eng.-ASCE, 125, 965-976. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:9(965)
  19. Shrimali, M.K. and Jangid, R.S. (2002), "Non-linear seismic response of base-isolated liquid storage tanks to bidirectional excitation", Nucl. Eng. Des., 217, 1-20. https://doi.org/10.1016/S0029-5493(02)00134-6
  20. Shrimali, M.K. and Jangid, R.S. (2004), "Seismic analysis of base-isolated liquid storage tank", J. Sound Vib., 275, 59-75. https://doi.org/10.1016/S0022-460X(03)00749-1
  21. Veletsos, A.S. (1984), "Seismic response and design of liquid storage tanks", Guidelines for Seismic Design of Oil & Gas Pipelines System, ASCE, NY, 255-370.
  22. Veletsos, A.S. and Young, T. (1977), "Earthquake response of liquid storage tanks", Proceedings of the 2nd Engineering Mechanics Specialty Conference, ASCE, Raleigh, 1-24.
  23. Wang, Y.P., Teng, M.C. and Chung, K.W. (2001), "Seismic isolation of rigid cylindrical tanks using friction pendulum bearings", Earthq. Eng. Struct. D., 30, 1083-1099. https://doi.org/10.1002/eqe.56
  24. Wozniak, R.S. and Mitchell, W.W. (1978), "Basis of seismic design provisions for welded steel oil storage tanks", American Petroleum Institute 43rd Midyear Meeting, Session on Advances in Storage Tank Design, Toronto, Canada.

피인용 문헌

  1. Repairable k-out-n system work model analysis from time response vol.12, pp.6, 2013, https://doi.org/10.12989/cac.2013.12.6.775
  2. Investigation of fresh concrete behavior under vibration using mass-spring model vol.57, pp.3, 2016, https://doi.org/10.12989/sem.2016.57.3.425
  3. Seismic analysis and modeling of isolated elevated liquid storage tanks vol.2, pp.4, 2010, https://doi.org/10.12989/eas.2011.2.4.397
  4. Dynamic response of a base-isolated CRLSS with baffle vol.66, pp.3, 2010, https://doi.org/10.12989/sem.2018.66.3.411