DOI QR코드

DOI QR Code

마이크로 드로플릿 셀 기법을 이용한 예민화 된 304 스테인리스강의 미세전기화학 특성

Micro-electrochemical Characteristics of Sensitized 304 Stainless steel Using Micro-droplet cell Techniques

  • 김규섭 (국민대학교 공과대학 신소재 공학부) ;
  • 이재봉 (국민대학교 공과대학 신소재 학부)
  • Kim, Kyu-Seop (School of Advanced Materials Engineering, Kookmin University) ;
  • Lee, Jae-Bong (School of Advanced Materials Engineering, Kookmin University)
  • 투고 : 2010.12.10
  • 심사 : 2010.12.28
  • 발행 : 2010.12.01

초록

The influences of sensitization on localized corrosion resistance of 304 stainless steel, were investigated, using micro-dropletcell techniques. Micro-droplet cell allows one to align the micro-electrode to the desired spot of the working electrode and measure directly local current with the potentiodynamic polarization, linear polarization and a.c. impedance. Micro-electrochemical tests were carried out inside of the grain and on grain boundaries separately. It was found that sensitization decreased the pitting potential, increasing corrosion current density around grain boundaries. Galvanic current density was also measured between grain and grain boundaries.

키워드

참고문헌

  1. Jae-bong Lee, Mater. Chem. Phys., 99, 224 (2006). https://doi.org/10.1016/j.matchemphys.2005.10.016
  2. Sim-Kun Min and Jae-Bong Lee, Kor. J. Met. Mater. 45. 305 (2007).
  3. D. A. Jones, Principles and Prevention of corrosion, 2nd ed., p. 292, Prentice Hall, NJ, 1996.
  4. Chan-Jin Park, Hyuk-Sang Kwon, and M.M. Lohrengel, Mater. Sci. Eng.(A), A372, 180 (2004).
  5. M. M. Lohrengel, A. Moehring, and M. Pilaski, Electrochim. Acta., 47. 137 (2001). https://doi.org/10.1016/S0013-4686(01)00570-9
  6. Y. R. Yoo, Y. I. Son, GT. Shim, Y. H. Kwon, and Y. S. Kim, Corros. Sci. Tech., 8, 22 (2009).
  7. Jae-Jung Kim and Jae-Bong Lee, Kor. J. Met. Mater., 46, 809 (2008).
  8. J.O. Park, S. Matsch, and H. Bohni, J. Electrochem. Soc., 149, B34 (2002). https://doi.org/10.1149/1.1430415
  9. ISO 12732, "corrosion of metals and alloys electrochemical potentiokinetic reactivation measurement using the double loop method(base on Cihal's method)" (2006).
  10. ASTM A 262-93a, "standard practices for detecting susceptibility to intergranular attack in austenitic stainless steels".
  11. N. Parvathavarthini, S. Mulki, R.K. Dayal, I. Samajdar, K.V. Mani, and Baldev Raj, Corros. Sci., 51, 2144 (2009). https://doi.org/10.1016/j.corsci.2009.05.045