Retrograde Stanford type A aortic dissection after endovascular stent graft placement for type B dissection

Stent graft 삽입치료 후 발생한 역행성 Stanford A형 대동맥 박리증 1예

  • Kim, Tae-Hoon (Department of Internal Medicine, Yonsei University College of Medicine) ;
  • Kim, Jung-Sun (Department of Internal Medicine, Yonsei University College of Medicine) ;
  • Lee, Chan-Joo (Department of Internal Medicine, Yonsei University College of Medicine) ;
  • Wi, Jin (Department of Internal Medicine, Yonsei University College of Medicine) ;
  • Yoon, Jin-Young (Department of Internal Medicine, Yonsei University College of Medicine) ;
  • Lee, Do-Yun (Department of Radiology, Yonsei University College of Medicine) ;
  • Choi, Dong-Hoon (Department of Internal Medicine, Yonsei University College of Medicine)
  • 김태훈 (연세대학교 의과대학 심장혈관병원 심장내과학교실) ;
  • 김중선 (연세대학교 의과대학 심장혈관병원 심장내과학교실) ;
  • 이찬주 (연세대학교 의과대학 심장혈관병원 심장내과학교실) ;
  • 위진 (연세대학교 의과대학 심장혈관병원 심장내과학교실) ;
  • 윤진영 (연세대학교 의과대학 심장혈관병원 심장내과학교실) ;
  • 이도연 (연세대학교 의과대학 심장혈관병원 영상의학과학교실) ;
  • 최동훈 (연세대학교 의과대학 심장혈관병원 심장내과학교실)
  • Received : 2009.09.08
  • Accepted : 2009.10.30
  • Published : 2010.09.01

Abstract

Endovascular stent graft placement in Stanford type B aortic dissection has increased as a result of the demonstration of its safety and efficacy. Despite the advantage of reduced mortality and morbidity, the mid-to long-term prognosis and possible complications associated with the procedure are a source of concern. Among the many possible complications, retrograde type A dissection after stent grafting for type B dissection is considered rare; however, this life-threatening event appears to be underrecognized. Here, we report a case that converted to open surgery due to a retrograde type A dissection after endovascular stent graft placement for a Stanford type B dissection. This is the first report of a retrograde type A dissection after endovascular stent graft placement in Korea.

대동맥 박리증에 대한 스텐트 그라프트 삽입치료 후의 합병증 중 역행성 A형 대동맥 박리증은 매우 드문 것으로 생각되어 왔으나 이 치명적인 합병증이 최근에 다수 보고되고 있다. 국내에서는 아직 이러한 역행성 대동맥 박리증의 발생에 대한 보고가 없으나 실제로는 상당수 발생하고 있을 것으로 생각되며 그 예방을 위해 환자에 따른 장비 및 장치(device)의 선택, 스텐트 그라프트 설계의 발전 그리고 혈관 내 시술의 표준화 및 안전화가 반드시 필요하다.

Keywords

References

  1. Chieffo A, Park SJ, Valgimigli M, Kim YH, Daemen J, Sheiban I, Truffa A, Montorfano M, Airoldi F, Sangiorgi G, Carlino M, Michev I, Lee CW, Hong MK, Park SW, Moretti C, Bonizzoni E, Rogacka R, Serruys PW, Colombo A. Favorable long-term outcome after drug-eluting stent implantation in nonbifurcation lesions that involve unprotected left main coronary artery: a multicenter registry. Circulation 116:158-162, 2007 https://doi.org/10.1161/CIRCULATIONAHA.107.692178
  2. Nienaber CA, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, Nicolas V, Pierangeli A. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med 340:1539-1545, 1999 https://doi.org/10.1056/NEJM199905203402003
  3. Dake MD, Kato N, Mitchell RS, Semba CP, Razavi MK, Shimono T, Hirano T, Takeda K, Yada I, Miller DC. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 340:1546-1552, 1999 https://doi.org/10.1056/NEJM199905203402004
  4. Czermak BV, Waldenberger P, Perkmann R, Rieger M, Steingruber IE, Mallouhi A, Fraedrich G, Jaschke WR. Placement of endovascular stent-grafts for emergency treatment of acute disease of the descending thoracic aorta. AJR Am J Roentgenol 179:337-345, 2002
  5. Lopera J, Patino JH, Urbina C, Garcia G, Alvarez LG, Upegui L, Jhanchai A, Qian Z, Castaneda-Zuniga W. Endovascular treatment of complicated type-B aortic dissection with stent-grafts: midterm results. J Vasc Interv Radiol 14:195-203, 2003
  6. Kato N, Shimono T, Hirano T, Suzuki T, Ishida M, Sakuma H, Yada I, Takeda K. Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: the complication-specific approach. J Thorac Cardiovasc Surg 124:306-312, 2002 https://doi.org/10.1067/mtc.2002.122302
  7. Dong ZH, Fu WG, Wang YQ, Guo da Q, Xu X, Ji Y, Chen B, Jiang JH, Yang J, Shi ZY, Zhu T, Shi Y. Retrograde type A aortic dissection after endovascular stent graft placement for treatment of type B dissection. Circulation 119:735-741, 2009 https://doi.org/10.1161/CIRCULATIONAHA.107.759076
  8. Neuhauser B, Greiner A, Jaschke W, Chemelli A, Fraedrich G. Serious complications following endovascular thoracic aortic stent-graft repair for type B dissection. Eur J Cardiothorac Surg 33:58-63, 2008 https://doi.org/10.1016/j.ejcts.2007.10.010
  9. Hata M, Sezai A, Niino T, Yoda M, Wakui S, Unosawa S, Umeda T, Shimura K, Osaka S, Furukawa N, Kimura H, Minami K. Prognosis for patients with type B acute aortic dissection: risk analysis of early death and requirement for elective surgery. Circ J 71:1279-1282, 2007 https://doi.org/10.1253/circj.71.1279
  10. Winnerkvist A, Lockowandt U, Rasmussen E, Radegran K. A prospective study of medically treated acute type B aortic dissection. Eur J Vasc Endovasc Surg 32:349-355, 2006 https://doi.org/10.1016/j.ejvs.2006.04.004
  11. Rubin S, Bayle A, Poncet A, Baehrel B. Retrograde aortic dissection after a stent graft repair of a type B dissection: how to improve the endovascular technique. Interact Cardiovasc Thorac Surg 5:746-748, 2006 https://doi.org/10.1510/icvts.2006.134957
  12. Savini C, Casselman F, Ergenoglu MU, Degrieck I, Van Praet F, De Geest R, Wellens F, Jeanmart H, Vanermen H. Surgical management of progression to type A dissection from an intramural hematoma previously treated with endovascular stent graft placement. J Thorac Cardiovasc Surg 128:773-775, 2004
  13. Panos A. Late retrograde aortic perforation by the uncovered part of an endograft: an increasing complication. Hellenic J Cardiol 48:115-116, 2007
  14. Modine T, Lions C, Destrieux-Garnier L, Haulon S, Decoene C, Beregi JP, Koussa M. Iatrogenic iliac artery rupture and type a dissection after endovascular repair of type B aortic dissection. Ann Thorac Surg 77:317-319, 2004 https://doi.org/10.1016/S0003-4975(03)00763-X