DOI QR코드

DOI QR Code

Design and Evaluation of a Uniform Flow Microreactor

균일 유동 마이크로 반응기의 설계와 검증

  • 박지민 (부산대학교 기계공학부 대학원) ;
  • 이승재 (부산대학교 기계공학부 대학원) ;
  • 김경천 (부산대학교 기계공학부)
  • Received : 2010.08.27
  • Accepted : 2010.09.21
  • Published : 2010.09.30

Abstract

This paper proposes a design method to provide uniform flow in a microreactor. Uniform momentum approach is adopted with 10 pillars before and after the chamber having a different slope inlet channel. The slope and number of pillars are two factors to make a uniform flow in the microreactor, covering the hexagonal gold layer. The CFD analysis about the designed microreactor is carried out and the velocity vector field measurements are made in the fabricated microreactor by micro PIV technique. The uniformity of microreactor flow was confirmed by both numerical simulation and experimental results.

Keywords

References

  1. Lei C.X., Gong F.C., Shen G.L., Yu R.Q., 2003, “Amperometric immunosensor for Schistosoma japonicum antigen using antibodies loaded on a nano-Au monolayer modified chitosan-entrapped carbon paste electrode”, Sensors and Actuators B: Chemical, Vol. 96, No. 3, pp 582-588. https://doi.org/10.1016/j.snb.2003.06.001
  2. Chen H. X., Kim Y. S., Keum S. R., Kim S. H., Choi H. J., Lee J. B., An W. G., Koh, K, 2007, “Surface Plasmon Spectroscopic Detection of Saxitoxin”, Sensors, Vol. 7, No. 7, pp 1216-1223. https://doi.org/10.3390/s7071216
  3. Lyon L. A., Musick M. D., Natan M. J., 1998, “Colloidal Au-Enhanced Surface Plasmon Resonance Immunosensing”, Anal. Chem., Vol. 70, No. 24, pp 5177-5183. https://doi.org/10.1021/ac9809940
  4. Lee J. B., Chen H. X., Lee J. W., Sun F. F., Kim C. M., Chang C. H., Koh, K., 2009, “A Possible Merge of FRET and SPR Sensing System for Highly Accurate and Selective Immunosensing”, Bull. Korean Chem. Soc., Vol. 30, No. 12, pp 2905-2908. https://doi.org/10.5012/bkcs.2009.30.12.2905
  5. Commenge J. M., Falk L., Corriou J. P., Matlosz M., 2002, “Optimal design for flow uniformity in microchannel reactors”, AIChE journal, Vol. 48, No. 2, pp 345-358. https://doi.org/10.1002/aic.690480218
  6. Yoon S. Y., Kim K. C., 2004, “Analysis of Flow in a Microchannel Branch by Using Micro-PIV Method”, Trans. of the KSME (B), Vol. 28, No. 9, pp 1015-1021.