Abstract
In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. An inelastic time history analysis of structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of semi-rigid connections were used for the models. A fiber model was utilized for the moment-curvature relationship of a steel beam and a column, a three-parameter power model for the moment-rotation angle of the semi-rigid connection, and a three-parameter model for the hysteretic behavior of a steel beam, column, and connection. The base-shear force, top displacement, story drift, required ductility for the connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were investigated using four earthquake excitations with peak ground acceleration for a mean return period of 2,400 years and for the maximum base-shear force in the pushover analysis of a 5% story drift. The maximum base-shear force and story drift decreased with the outer vertical distribution of the semi-rigid connection, and the required ductility for the connection decreased with the higher horizontal distribution of the semi-rigid connection. The location of the maximum story drift differed in the pushover analysis and the time history analysis, and the magnitude was overestimated in the pushover analysis. The outer vertical distribution of the semi-rigid connection was recommended for the base-shear force, story drift, and required ductility for the connection.
본 연구에서는 반강접 접합부 배치에 따른 구조물 거동특성을 파악하기 위하여 KBC2005 건축구조설계기준으로 비가새 5층 철골 구조물을 설계하여 모든 접합부를 완전 강접합부와 반강접 접합부로 이상화한 경우 그리고 반강접 접합부를 수직배치 및 수평배치한 경우에 대하여 비탄성 시간이력 구조해석을 실시하였다. 철골 보 및 기둥의 모멘트-곡률 관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델 그리고 철골 보, 기둥 및 접합부의 이력거동은 3-매개변수 모델을 이용하여 나타내었다. 4개 지진파에 대한 재현주기 2400년 위험수준에 해당하는 최대지반가속도와 5% 층간변위에 대한 푸쉬오버 구조해석의 최대밑면전단력 발생 최대지반가속도에 대하여 시간이력 구조해석을 실시하여 밑면전단력, 지붕층 변위, 층간변위, 접합부 요구연성도, 기둥, 보 및 접합부의 최대휨모멘트 그리고 소성힌지 분포 등을 확인하였다. 반강접 접합부를 수직적으로 외부에 배치할수록 최대밑면전단력과 층간변위는 감소하며, 수평적으로 상부층에 배치할수록 접합부 요구연성도가 감소하였다. 푸쉬오버 구조해석과 시간이력 구조해석에서 최대층간변위 발생 위치가 다르고 크기는 푸쉬오버 구조해석에서 과대평가되었다. 밑면전단력, 층간변위 및 접합부 요구연성도를 위한 가장 바람직한 반강접 접합부 배치는 수직적으로 외부에 배치하는 것이다.